Smart Grid Technology

Chapter 12
Cybersecurity, Privacy and Safety

Bachelors Program in Electrical Engineering
Smart Grid Technology   •   Bachelor

Cybersecurity, Privacy and Safety

Introduction

A smart grid is a cyber-physical energy system: electrical equipment, communications networks, software, markets, operators, and consumers interact continuously. This integration improves observability, efficiency, renewable-energy integration, and resilience, but it also creates pathways through which a cyber incident can become a physical disturbance. A compromised control command may alter breaker states; falsified measurements may mislead automatic protection or state estimation; ransomware may make operational data unavailable; and excessive collection of household data may violate privacy even when no physical damage occurs.

Smart-grid security therefore has three inseparable dimensions:

  • Cybersecurity: preserving confidentiality, integrity, and availability of information and systems.
  • Privacy: controlling the collection, use, disclosure, retention, and inference of information about people and organizations.
  • Safety and resilience: preventing unacceptable harm to people, equipment, the environment, and continuity of essential electricity services.

The engineering challenge is not to make every component equally secure. It is to manage risk according to consequences, exposure, operational constraints, and recovery requirements. Security controls must coexist with deterministic protection functions, long equipment lifetimes, limited bandwidth, legacy protocols, and the requirement that electricity remain safe and available.

Learning objectives

After studying this chapter, a student should be able to:

  1. Explain the cyber-physical attack surface of a smart grid.
  2. Distinguish threats, vulnerabilities, risks, impacts, and controls.
  3. Analyze how attacks affect confidentiality, integrity, availability, safety, and resilience.
  4. Design a defense-in-depth architecture using segmentation, authentication, encryption, access control, monitoring, and recovery.
  5. Apply privacy-by-design principles to advanced metering and grid analytics.
  6. Describe incident-response processes and relevant standards and governance responsibilities.
  7. Evaluate trade-offs between security, operational performance, cost, privacy, and safety.

1. The smart-grid attack surface

A conventional power system already contains protection relays, control centers, and telecommunications. A smart grid adds advanced meters, distributed energy resources (DERs), electric-vehicle chargers, home energy-management systems, cloud platforms, application programming interfaces, wireless networks, and third-party aggregators. Each connection can provide useful functionality and also create an attack surface.

Important assets include:

  • generation, transmission, distribution, and substation control systems;
  • supervisory control and data acquisition (SCADA), energy-management systems (EMS), and distribution-management systems (DMS);
  • intelligent electronic devices (IEDs), programmable logic controllers, protection relays, and phasor measurement units;
  • advanced metering infrastructure (AMI), meter data management systems, and customer portals;
  • DER controllers, inverter firmware, battery-management systems, and EV charging infrastructure;
  • engineering workstations, portable maintenance devices, identity services, time sources, and backups;
  • operational technology (OT) networks, information technology (IT) networks, radio systems, fiber links, and cloud services.

A useful distinction is between safety-critical, mission-critical, and business-critical assets. A protection relay may be safety- and mission-critical because a false or delayed action can damage equipment. A customer billing server may be business-critical but normally has a different immediate physical consequence. Classification supports proportionate controls.

2. Threat, vulnerability, risk, and impact

A threat is a potential cause of an unwanted event. Threat actors include criminal groups, insiders, hacktivists, competitors, terrorists, and state-sponsored organizations. Threats may be deliberate or accidental. A misconfigured firewall and a malicious command can have similar operational consequences.

A vulnerability is a weakness that can be exploited or triggered. Examples include default passwords, unpatched firmware, excessive privileges, exposed remote-access services, insecure legacy protocols, poor key management, inadequate physical protection, and insufficient supplier oversight.

Risk combines the likelihood of an event with its consequences. A simple screening model is:

R = P(E) × C(E)

where R is risk, P(E) is the estimated probability of event E, and C(E) is its consequence. This is not a universal law or a precise probability calculation; it is a prioritization model. In practice, consequence may be multidimensional, including safety, reliability, financial, environmental, legal, and reputational effects. Low-probability events with catastrophic consequences may require controls even when their numerical product appears modest.

A vulnerability does not automatically imply a successful attack. Exploitability depends on reachability, authentication, protocol behavior, detection, and the attacker's capability. Conversely, an apparently minor compromise may become serious through cascading effects. For example, manipulated voltage measurements may cause incorrect control decisions, which produce voltage excursions, equipment trips, and loss of supply.

3. Cyber-physical threat mechanisms

3.1 Loss of confidentiality

Confidentiality failures expose customer identities, consumption patterns, maintenance schedules, network diagrams, credentials, or market information. Meter data can reveal occupancy, work schedules, appliance use, and potentially medical or industrial activity. Engineering drawings and relay settings can help an attacker plan a more damaging intrusion.

3.2 Loss of integrity

Integrity attacks alter commands, configurations, firmware, logs, measurements, time signals, or software. They are especially dangerous in control systems because a plausible false value may be more harmful than an obviously missing value. Examples include false-data injection against state estimation, falsified frequency measurements, unauthorized relay-setting changes, and altered firmware.

For a measurement vector z, a state estimator may compare measured values with model-predicted values. If an attacker adds a carefully constructed vector a, the received measurements become z' = z + a. If the altered data remains within detection thresholds, the operator or automated controller may accept an incorrect system state. Real systems use redundancy, topology checks, bad-data detection, physical laws, and independent measurements, but none is perfect.

3.3 Loss of availability

Availability attacks prevent authorized users or systems from obtaining services. Distributed denial-of-service attacks, ransomware, jamming, destructive malware, power loss to communications equipment, and denial of authentication services are examples. Availability is not simply an IT concern: delayed control or missing telemetry may remove an operator's ability to maintain a safe operating envelope.

3.4 Spoofing and impersonation

An attacker may impersonate an operator, field device, vendor, or trusted server. Weak mutual authentication, stolen certificates, shared accounts, and insecure remote access facilitate this threat. Spoofing can combine confidentiality and integrity failures because the attacker both observes traffic and issues apparently legitimate commands.

3.5 Supply-chain and insider threats

Grid organizations depend on equipment manufacturers, software suppliers, telecommunications providers, integrators, and cloud operators. Compromised update mechanisms, counterfeit components, malicious code, undocumented accounts, and vulnerable third-party libraries create supply-chain risks. Insiders may misuse legitimate privileges, knowingly or accidentally. Least privilege, separation of duties, screening, monitoring, and independent approval reduce—but cannot eliminate—these risks.

3.6 Physical and environmental threats

Cybersecurity controls must account for cabinet access, removable media, damaged fiber, electromagnetic interference, theft, fire, flooding, and extreme weather. Physical access can bypass logical controls, while a storm can simultaneously create physical faults and communications outages. Security, safety, reliability, and business continuity planning should therefore be coordinated rather than managed as isolated disciplines.

4. Security objectives and engineering trade-offs

The traditional security triad is confidentiality, integrity, and availability (CIA). Smart-grid engineering adds authenticity, accountability, safety, resilience, and privacy.

ObjectiveSmart-grid meaningTypical control
ConfidentialityPrevent unauthorized disclosureEncryption and data minimization
IntegrityPrevent unauthorized or undetected alterationMessage authentication, signed firmware, validation
AvailabilityMaintain timely serviceRedundancy, backups, rate limiting, recovery
AuthenticityEstablish who or what is communicatingCertificates, mutual authentication
AccountabilityLink actions to responsible identitiesAudit logs and time synchronization
SafetyPrevent unacceptable physical harmInterlocks, fail-safe states, independent protection
ResilienceAbsorb, adapt to, and recover from disruptionSegmentation, islanding, restoration plans

Controls can conflict with operational requirements. Strong encryption may increase latency or require key infrastructure. Multifactor authentication may be difficult during a field emergency or communications outage. Automatic patching can disrupt a controller. Detailed logging can create privacy risks. Safety functions should not depend on a single remote server or an untested security mechanism. Engineering decisions must document assumptions, failure modes, compensating controls, and approval authority.

5. Defense in depth

Defense in depth uses multiple partially independent layers so that failure of one control does not expose the whole system. A representative architecture has the following zones:

  1. Enterprise zone: office systems, email, and business applications.
  2. Industrial demilitarized zone (DMZ): controlled exchange services, historians, patch repositories, and remote-access gateways.
  3. Supervisory zone: control-center applications and operator workstations.
  4. Control zone: substation and plant controllers, relays, and local networks.
  5. Field and process zone: sensors, actuators, meters, and physical equipment.

A firewall alone is insufficient. Effective defense in depth combines asset inventory, secure configuration, segmentation, allow-list communications, identity management, encryption where appropriate, endpoint protection, physical security, monitoring, tested backups, and recovery procedures.

Segmentation should be based on function and consequence, not merely organizational ownership. A high-consequence relay network should not share unrestricted pathways with office laptops. Remote access should terminate at a managed gateway, use individual accounts and strong authentication, be time-limited, record sessions where lawful, and be disabled when not required. Direct exposure of control devices to the public internet is unacceptable.

Authentication and authorization

Authentication answers “who or what are you?” Authorization answers “what may you do?” Accounting records what occurred. These are distinct functions. Passwords alone are weak for privileged access; stronger methods include certificates, hardware tokens, and multifactor authentication. Device identity is important because many grid messages are machine-to-machine.

Role-based access control assigns permissions according to job role. Attribute-based access control can additionally consider location, device posture, time, task, and operational state. Privileges should be least-necessary, reviewed periodically, and separated for configuration, approval, and execution. Emergency accounts require strict logging and post-event review.

Cryptography and key management

Encryption protects confidentiality, while message authentication codes and digital signatures protect integrity and authenticity. Encryption in transit does not protect a compromised endpoint, and encryption at rest does not prevent an authorized user from misusing data. Cryptography is effective only when algorithms, implementations, certificates, keys, clocks, and revocation procedures are managed correctly.

Key management includes secure generation, distribution, storage, rotation, backup, revocation, recovery, and destruction. A utility should define certificate ownership and what happens when a device is replaced or loses connectivity. Long-lived grid equipment creates a migration problem: algorithms and certificate systems selected today must remain supportable for decades. Organizations should monitor post-quantum cryptography developments without deploying unvalidated mechanisms in safety-critical systems.

Secure development and maintenance

Security should begin in requirements and architecture, not after deployment. Secure development includes threat modeling, code review, dependency management, vulnerability testing, signed updates, reproducible build practices where feasible, and coordinated vulnerability disclosure. Maintenance requires a complete asset and software inventory, risk-based patch testing, configuration baselines, backup validation, and documented compensating controls when patching is impossible.

6. Detection, response, and recovery

Prevention is only one part of security. Detection uses logs, network-flow records, endpoint telemetry, authentication events, configuration changes, process alarms, and physical observations. OT monitoring should be adapted to deterministic protocols and fragile legacy devices; aggressive scanning can itself cause disruption. Baselines should distinguish normal switching, maintenance, and seasonal behavior from suspicious activity.

A practical incident-response lifecycle is:

  1. Preparation: establish roles, contacts, playbooks, backups, exercises, and legal procedures.
  2. Detection and analysis: validate alerts, establish scope, preserve evidence, and assess safety.
  3. Containment: isolate affected zones or accounts while avoiding unsafe loss of control.
  4. Eradication: remove malicious code, reset credentials, correct configurations, and address the entry path.
  5. Recovery: restore from trusted images, verify system behavior, monitor closely, and return service in stages.
  6. Lessons learned: identify root causes, update controls, report where required, and improve training.

The first question in an OT incident is often not “How do we disconnect everything?” but “What action preserves a safe operating state?” Isolation may be manual, logical, physical, or staged. Operators, safety engineers, cybersecurity personnel, communications staff, management, law enforcement, and suppliers need predefined authority boundaries.

Recovery objectives should be explicit. Recovery time objective (RTO) is the maximum acceptable time to restore a service. Recovery point objective (RPO) is the maximum acceptable age of restored data. These values are business and operational requirements, not merely technology settings. Backups must be offline or otherwise protected from ransomware, periodically restored in tests, and accompanied by trusted configurations and documentation.

7. Privacy in the smart grid

Privacy concerns arise because smart meters can produce fine-grained, high-frequency records. Even when a record contains no name, it may be linkable to an address, account, device identifier, or public information. Privacy risk includes direct disclosure, unauthorized secondary use, profiling, discriminatory pricing, inference of occupancy, and re-identification after datasets are combined.

Privacy-by-design embeds protection throughout the system lifecycle. Its practical principles include:

  • Purpose limitation: collect data for specified legitimate purposes.
  • Data minimization: collect the least detail needed for the task.
  • Local processing: perform analysis at the meter, home gateway, or substation when feasible.
  • Access limitation: permit only authorized uses and personnel.
  • Retention limitation: delete or aggregate data when the purpose ends.
  • Transparency and control: inform customers and provide lawful choices.
  • Protection and accountability: secure data and document decisions.

A utility may need interval data for demand response but only monthly totals for billing. Aggregation reduces detail, although it does not guarantee anonymity. Masking identifiers is not equivalent to anonymization if records can be linked again. Differential privacy can add carefully calibrated randomization to published statistics, but it introduces accuracy trade-offs and requires disciplined management of the privacy budget. It is not a substitute for access control or encryption.

Privacy governance should address ownership, lawful basis, consent where applicable, data-sharing agreements, cross-border transfers, breach notification, customer access and correction, vendor obligations, and independent audits. Applicable law varies by jurisdiction; engineering teams must work with legal and compliance specialists rather than assuming that one privacy rule applies globally.

8. Safety and security interdependence

Safety engineering asks whether hazards can harm people or equipment; cybersecurity asks whether adversarial or accidental actions can create those hazards. The disciplines overlap but are not identical. A safety system may place equipment in a de-energized state, while availability-focused cybersecurity might seek continuous operation. A secure remote command may still be unsafe if the plant is in an unexpected physical condition.

Useful principles include independent protection layers, fail-safe design, defense against common-cause failures, manual fallback, interlocks, clear alarm priorities, and verification of assumptions under degraded communications. Safety instrumented functions and protection relays should not rely solely on a general-purpose network or cloud service. Cybersecurity threat modeling should identify safety consequences, and safety analyses should consider malicious manipulation, spoofed sensor values, and loss of control.

9. Standards and governance frameworks

Standards provide structured practices but do not guarantee security. Important references include:

  • NIST Cybersecurity Framework 2.0: Govern, Identify, Protect, Detect, Respond, and Recover functions for managing cybersecurity risk.
  • NIST SP 800-82: guidance for securing industrial control systems.
  • IEC 62443: a family addressing industrial automation and control-system security, including asset-owner, system, component, and service-provider perspectives.
  • ISO/IEC 27001: requirements for an information-security management system; it is broader than OT and must be adapted to operational conditions.
  • IEC 62351: security measures for power-system communications and related protocols.
  • NERC CIP: mandatory cybersecurity requirements for certain bulk-electric-system entities in jurisdictions where applicable.
  • IEC 61508 and related functional-safety standards: principles for safety-related electrical, electronic, and programmable systems.

Governance assigns responsibility. The board and senior management set risk appetite and resources; asset owners define operational requirements; engineers implement and verify controls; operators manage real-time conditions; suppliers provide secure products and disclosure support; regulators establish obligations; and customers receive transparent information. Metrics should measure meaningful outcomes, such as privileged-account review completion, restoration-test success, unapproved remote sessions, mean time to detect, and coverage of critical assets—not merely the number of policies written.

10. Illustrative case: compromise of a distribution utility

Background

Consider a fictional midsize distribution utility, North Valley Electric. It operates automated substations, AMI, a DMS, and a vendor-maintained remote-access platform. The utility has strong perimeter firewalls but incomplete asset inventories and several shared engineering accounts.

Problem

An attacker obtains a vendor credential through phishing. The credential provides remote access to a maintenance gateway. The attacker enters outside approved hours, explores the network, and installs malware on an engineering workstation. From there, the attacker attempts to alter distribution automation settings and suppress selected alarms.

Analysis

The perimeter control did not fail in isolation; identity governance, account separation, remote-access approval, monitoring, and segmentation were inadequate. The workstation had a route to a control zone that should have been mediated by a stronger industrial DMZ. A single alert about unusual login time was not correlated with configuration changes. The potential consequences included incorrect feeder operation, customer outages, equipment stress, and delayed operator response.

Approach and solution

The utility first assessed whether any unsafe switching had occurred and placed affected feeders under approved local or manual control. It disabled the vendor account, preserved forensic images, isolated the workstation, and blocked unauthorized paths without disconnecting protection functions. It restored the workstation from a trusted image and validated relay and controller configurations against known-good baselines.

Longer-term actions included unique named accounts, multifactor authentication for remote access, time-limited vendor sessions, session recording subject to law, stronger DMZ separation, allow-list communications, independent approval for configuration changes, centralized time synchronization, improved alert correlation, quarterly access reviews, and restoration exercises. The utility also required suppliers to provide a current software bill of materials and vulnerability-notification process.

Outcome

No physical damage occurred, but the event caused a controlled interruption to maintenance operations and required enhanced monitoring. The post-incident review found that security investment in perimeter devices had not been matched by identity, segmentation, and recovery capabilities.

Learning points

  1. A trusted supplier connection is an attack path, not a security boundary.
  2. Security events must be interpreted in an operational and safety context.
  3. Configuration integrity and known-good baselines are essential for recovery.
  4. Shared accounts weaken accountability and incident investigation.
  5. Exercises should test decisions under degraded control, not only IT restoration.

11. Contemporary developments and limitations

Cloud computing and edge analytics can improve scalability but expand dependence on identity providers, APIs, and telecommunications. Artificial intelligence can help classify alerts, detect unusual behavior, and prioritize vulnerabilities. However, AI systems can generate false positives, be misled by poisoned data, reveal sensitive information, or produce explanations inadequate for safety decisions. AI should support—not replace—qualified operators and engineers, with human approval for high-consequence actions.

The increasing number of inverter-based resources creates new coordination and firmware risks. EV chargers can become large, distributed control populations. 5G and software-defined networking may improve latency and flexibility while introducing new orchestration and supply-chain dependencies. Quantum computing remains a future cryptographic concern; utilities should inventory cryptographic dependencies and favor upgradeable architectures.

No control is perfect. Encryption cannot correct malicious logic in an authorized application. Segmentation can fail through misconfiguration. Anomaly detection can miss novel attacks. Privacy protections can reduce analytical resolution. Safety isolation can reduce availability. Good design makes these limitations explicit, tests assumptions, and provides independent layers and recovery options.

Best-practice design checklist

A smart-grid project should, at minimum:

  • maintain an ownership-based inventory of hardware, software, data flows, and dependencies;
  • classify assets by safety, reliability, privacy, and business consequence;
  • perform threat modeling and update it after architectural or operational changes;
  • segment IT, OT, supervisory, control, and field environments;
  • use unique identities, least privilege, multifactor authentication where feasible, and controlled service accounts;
  • protect communications and data with appropriate cryptography and disciplined key management;
  • establish secure configuration, patch, vulnerability-disclosure, and supplier-management processes;
  • monitor for suspicious identity, network, configuration, and physical events;
  • maintain offline or otherwise protected backups and test restoration;
  • integrate cybersecurity with safety management, emergency operations, and continuity planning;
  • minimize personal data, define retention, and document lawful uses;
  • exercise incident response with operators, engineers, suppliers, and leadership;
  • measure performance through evidence and continuously improve.

Chapter Summary

Smart-grid cybersecurity is a cyber-physical engineering discipline concerned with confidentiality, integrity, availability, authenticity, accountability, privacy, safety, and resilience. Threats may arise from criminals, insiders, suppliers, accidents, environmental events, or state-sponsored actors. Vulnerabilities include weak identity management, insecure legacy protocols, poor segmentation, unpatched systems, exposed remote access, and inadequate recovery capability.

Risk analysis links event likelihood and consequences, while cyber-physical analysis examines how information-system compromise can produce physical disturbance. Defense in depth combines asset identification, segmentation, authentication, authorization, cryptography, secure maintenance, monitoring, incident response, and tested recovery. Privacy-by-design limits collection and use of customer data through purpose limitation, minimization, local processing, access control, retention limits, transparency, and accountability. Safety requires independent protection, fail-safe behavior, manual fallback, and explicit analysis of malicious or degraded conditions.

NIST CSF 2.0, NIST SP 800-82, IEC 62443, IEC 62351, ISO/IEC 27001, NERC CIP where applicable, and functional-safety standards provide complementary guidance. They must be applied intelligently to the utility’s architecture and jurisdiction. The most mature organizations treat security as a lifecycle responsibility, verify restoration, manage suppliers, protect privacy, and rehearse decisions before an incident occurs.

Key Terms

Threat: A potential cause of an unwanted event.

Vulnerability: A weakness that can be exploited or triggered.

Risk: The combination of the likelihood and consequence of an event.

Cyber-physical system: A system in which computational, communication, and physical processes interact.

SCADA: Supervisory control and data acquisition system for monitoring and control.

OT: Operational technology that monitors or controls physical processes.

Defense in depth: Multiple complementary and partially independent security layers.

Segmentation: Dividing a network into controlled security or functional zones.

Authentication: Verification of an identity.

Authorization: Determination of permitted actions.

Least privilege: Granting only the access necessary for an approved task.

Encryption: Transformation of data to restrict unauthorized reading.

Integrity: Assurance that data or configurations have not been improperly altered.

Incident response: Coordinated process for detecting, containing, eradicating, and recovering from incidents.

Resilience: Capacity to withstand, adapt to, and recover from disruption.

Privacy by design: Incorporating privacy protection throughout the system lifecycle.

Data minimization: Collection and retention of only necessary information.

RTO: Maximum acceptable time to restore a service.

RPO: Maximum acceptable age of data used for restoration.

Industrial DMZ: Controlled intermediary network between enterprise and control environments.

Review Questions

Short Answer Questions

  1. Distinguish a threat from a vulnerability and a risk.
  2. Why can integrity attacks be more dangerous than simple loss of data in a smart grid?
  3. What is the purpose of an industrial DMZ?
  4. State three principles of privacy by design.
  5. Why must incident response include safety assessment?

Long Answer Questions

  1. Explain the smart-grid attack surface and classify representative assets by consequence.
  2. Describe a defense-in-depth architecture for a distribution utility.
  3. Compare authentication, authorization, accounting, encryption, and digital signatures.
  4. Explain how privacy risks arise from advanced metering and how they can be reduced.
  5. Discuss how cybersecurity and functional safety should be coordinated in an automated substation.

Analytical / Application Questions

  1. A vendor requires remote access to a substation controller for four hours. Design an approval, authentication, monitoring, segmentation, and post-access review process.
  2. A utility detects altered voltage measurements but no confirmed equipment damage. Analyze possible cyber-physical impacts and propose immediate containment and recovery actions.
  3. An energy program wants 15-minute household meter data for demand response. Evaluate the privacy, operational, and analytical trade-offs and recommend a privacy-preserving design.

Multiple Choice Questions with Answers

Question 1

Which property is most directly violated when an attacker changes relay settings without authorization?

A. Confidentiality

B. Integrity

C. Availability

D. Privacy

Correct Answer: B. Integrity

Question 2

What is the primary purpose of an industrial DMZ?

A. To replace all endpoint authentication

B. To provide an uncontrolled high-speed path between IT and OT

C. To mediate and control exchanges between enterprise and control environments

D. To store customer billing records permanently

Correct Answer: C. To mediate and control exchanges between enterprise and control environments

Question 3

Which practice best supports accountability for privileged grid operations?

A. Using one shared administrator account

B. Disabling event logging to improve performance

C. Using named accounts with auditable logs

D. Allowing anonymous emergency access

Correct Answer: C. Using named accounts with auditable logs

Question 4

Which statement about encryption is correct?

A. It guarantees that an authorized application cannot misuse data

B. It can protect confidentiality but requires sound key management

C. It eliminates the need for access control

D. It prevents all denial-of-service attacks

Correct Answer: B. It can protect confidentiality but requires sound key management

Question 5

Which action is an example of data minimization?

A. Collecting the finest interval data for every purpose

B. Retaining all customer data indefinitely

C. Using monthly totals when 15-minute readings are not needed

D. Publishing identifiable meter readings openly

Correct Answer: C. Using monthly totals when 15-minute readings are not needed

Question 6

What is the first priority when responding to a suspected OT compromise?

A. Immediately disconnect every protection device

B. Preserve a safe operating state while assessing scope

C. Delete all system logs

D. Restore from any available backup without validation

Correct Answer: B. Preserve a safe operating state while assessing scope

Question 7

Which framework function includes restoration of capabilities after an incident?

A. Recover

B. Identify

C. Protect

D. Govern

Correct Answer: A. Recover

Question 8

A recovery point objective primarily describes:

A. The maximum acceptable age of restored data

B. The number of authorized operators

C. The maximum network bandwidth

D. The physical distance between substations

Correct Answer: A. The maximum acceptable age of restored data

Question 9

Which control most directly limits what an authenticated technician may do?

A. Authorization

B. Encryption

C. Data aggregation

D. Environmental monitoring

Correct Answer: A. Authorization

Question 10

Why is a trusted supplier connection still a security concern?

A. Suppliers cannot use authentication

B. It is an external pathway that may be compromised or misused

C. Supplier equipment never communicates with OT

D. It automatically disables all firewalls

Correct Answer: B. It is an external pathway that may be compromised or misused

Smart Grid Technology
Chapter 12 of 15