Bachelors Program in Mechnical Engineering
Renewable & Sustainable Energy Systems
•
Bachelor
Solar Energy Systems
Introduction and context
Solar radiation is the most abundant renewable energy resource available to Earth. It can be converted directly into electricity by photovoltaic (PV) devices or indirectly into useful heat through solar thermal collectors. The engineering challenge is not simply to collect sunlight, but to match a variable resource with electrical and thermal loads while controlling losses, cost, safety, and environmental impacts.
Solar-system design combines astronomy, heat transfer, semiconductor physics, power electronics, structural engineering, controls, and reliability analysis. A technically sound design must therefore answer five questions: how much solar energy is available, how much reaches the collector or module, how efficiently it is converted, how the energy is delivered to the load, and how the system performs over its service life.
Learning objectives
After studying this chapter, the reader should be able to:
Define solar geometry and calculate sun position and plane-of-array irradiance.
Explain direct, diffuse, and reflected solar radiation and the effects of shading.
Describe PV-cell operation, module construction, inverter functions, and maximum-power-point tracking.
Apply energy balances to flat-plate and concentrating solar collectors.
Size a basic solar water-heating or grid-connected PV system.
Evaluate performance, reliability, safety, environmental, and regulatory considerations.
1. Solar resource and radiation
Solar irradiance is the instantaneous solar power incident on a surface, measured in W/m². Solar irradiation is irradiance integrated over time, commonly expressed in kWh/m²/day or MJ/m²/day. At the mean Earth–Sun distance, the solar constant is approximately 1,361 W/m² outside the atmosphere on a surface normal to the rays. Ground-level values are lower because of atmospheric absorption, scattering, and reflection.
Radiation reaching a surface is commonly divided into:
Beam or direct radiation: radiation arriving from the solar disk without significant atmospheric scattering.
Diffuse radiation: radiation scattered by molecules, aerosols, and clouds.
Ground-reflected radiation: radiation reflected from the surroundings onto the receiving surface.
For a tilted plane, the total irradiance is often represented by
GT = Gb Rb + Gd Fsky + ρg Gh Fg
where GT is tilted-plane irradiance, Gb is horizontal beam irradiance, Rb is the beam conversion factor, Gd is horizontal diffuse irradiance, Fsky is the view factor from the plane to the sky, ρg is ground reflectance, Gh is global horizontal irradiance, and Fg is the ground view factor. This expression is a simplified isotropic-sky model. More advanced anisotropic models account separately for circumsolar and horizon-brightening effects.
Daily or monthly energy estimates should use measured meteorological data, a typical meteorological year, or a validated solar-resource database. A single “average sunny day” is inadequate for reliability or financial design because clouds, temperature, aerosols, and seasonal changes strongly affect output.
2. Solar geometry
Solar geometry establishes the position of the Sun relative to a receiving surface. The principal quantities are:
Latitude, φ: angular position north or south of the equator.
Declination, δ: angular position of the Sun north or south of the equatorial plane.
Hour angle, ω: angular displacement from local solar noon; it is zero at noon and changes by approximately 15° per hour.
Solar altitude, α: angle between the Sun and the horizontal plane.
Solar zenith angle, θ_z: angle between the Sun’s rays and the vertical; α = 90° − θz.
Solar azimuth: horizontal direction of the Sun, measured using a stated convention.
An approximate declination relation for day number n is
δ ≈ 23.45° sin[360°(284 + n)/365]
This is suitable for preliminary engineering calculations. Accurate work should use a recognized solar-position algorithm and distinguish clock time from solar time.
For a horizontal surface, the solar zenith angle is given by
cos θz = sin φ sin δ + cos φ cos δ cos ω
The sunrise or sunset hour angle for a level horizon satisfies
cos ωs = −tan φ tan δ
The equation applies when the argument lies between −1 and +1. Polar regions can experience polar day or polar night, in which case the usual sunrise and sunset interpretation must be modified. Solar-day length is
N = 2ωs/15°
where N is in hours if ωs is in degrees.
For a tilted surface, the incidence angle depends on latitude, declination, hour angle, surface tilt, surface azimuth, and the selected azimuth convention. In practice, software or a validated algorithm is preferred because sign errors are common. A useful physical rule remains: beam collection is greatest when the module normal points toward the Sun. Fixed arrays are usually tilted approximately toward the equator, but the optimum angle depends on latitude, season, load profile, roof geometry, wind, snow, and economics.
Solar geometry showing the sun, horizontal plane, tilted collector, and angles
Figure: Solar geometry showing the sun, horizontal plane, tilted collector, and angles
Figure: Solar rays, collector tilt, and incidence angle. The collector receives maximum beam power when the rays are normal to its surface.
3. Shading, soiling, and optical losses
Shading is a geometric and electrical problem. A chimney, parapet, tree, or adjacent row may block direct radiation. Because cells in a module are electrically interconnected, partial shading can reduce output disproportionately. Bypass diodes limit reverse-bias stress in shaded cell substrings, but they do not eliminate energy loss or mismatch.
A shading study should include a three-dimensional horizon survey, annual sun-path analysis, row-to-row spacing, seasonal shadows, and the electrical layout. For a row of fixed collectors, increasing spacing reduces shading but uses more land. Near the winter solstice, the solar altitude is often low; therefore winter shadows may dominate the design even where annual energy is the primary objective.
Common losses include reflection at glazing, dust and snow, optical incidence-angle effects, temperature, wiring resistance, inverter conversion, module mismatch, and availability. Losses should be represented explicitly rather than hidden in an arbitrary “derating factor.” Cleaning frequency should be based on local soiling rates, water availability, labor, and the production value of recovered energy.
4. Photovoltaic conversion
A PV cell is a semiconductor p–n junction. Photons with energy exceeding the semiconductor band gap generate electron–hole pairs. The internal electric field separates these carriers, producing a photocurrent when an external circuit is connected. Silicon dominates the market because of its suitable band gap, abundance, manufacturing maturity, and durability.
The idealized single-diode equation is
I = Iph − I0 {exp[(V + I Rs)/(nVT)] − 1} − (V + I Rs)/Rsh
where I and V are cell current and voltage; Iph is photocurrent; I0 is diode saturation current; Rs and Rsh are series and shunt resistances; n is the diode ideality factor; and VT = kT/q is the thermal voltage. Here k is Boltzmann’s constant, T absolute temperature in kelvin, and q the elementary charge. The equation is a model, not a complete description of every cell, and its parameters must be obtained from measurements or manufacturer data.
The cell power is
P = VI
The maximum-power point is the point on the current–voltage curve at which P is greatest. Important data-sheet quantities are short-circuit current Isc, open-circuit voltage Voc, maximum-power voltage Vmp, maximum-power current Imp, and fill factor:
FF = (Vmp Imp)/(Voc Isc)
The fill factor is dimensionless and indicates the squareness of the I–V curve. Cell current generally increases approximately with irradiance, while voltage decreases as cell temperature rises. A common approximate temperature correction is
P(Tc) ≈ Pref[1 + γP(Tc − Tref)]
where γP is the manufacturer’s power temperature coefficient, usually negative and expressed per °C, and Tc and Tref are cell and reference temperatures. This linear relation is local and should not be extrapolated beyond the manufacturer’s stated range.
Cells are connected in series to increase voltage and in parallel to increase current. A module includes cells, encapsulant, front glass, a backsheet or rear glass, frame, junction box, and bypass diodes. Modules are combined into strings and arrays. String voltage must remain within inverter operating and maximum-voltage limits at the lowest expected cell temperature; string current, connectors, fuses, and conductors must be selected for the highest expected operating and fault conditions.
5. Inverters and maximum-power-point tracking
An inverter converts DC electricity to AC electricity. A grid-connected inverter synchronizes voltage, frequency, and phase with the grid and normally includes anti-islanding protection, monitoring, and protective functions. A stand-alone inverter must regulate an AC waveform for local loads, often with batteries or another dispatchable source.
Maximum-power-point tracking (MPPT) adjusts the electrical operating point so that the PV array operates near its maximum power. The condition for maximum power is
dP/dV = 0
Since P = VI,
dP/dV = I + V(dI/dV) = 0
Therefore, at the maximum-power point, the incremental conductance condition is
dI/dV = −I/V
Perturb-and-observe control slightly changes voltage and observes whether power increases or decreases. Incremental-conductance control compares dI/dV with −I/V and can respond better to changing irradiance, though it requires more sensing and control logic. Under partial shading, the I–V curve may contain multiple local maxima; a simple tracker can select a local rather than global maximum. Module-level power electronics can reduce mismatch but increase cost, electronics count, and maintenance exposure.
6. Solar thermal collectors
A solar thermal collector transfers absorbed solar radiation to a working fluid. Flat-plate collectors use a dark absorber, transparent cover, insulation, casing, and fluid passages. Evacuated-tube collectors reduce convective losses and are effective at higher temperature differences. Unglazed collectors are inexpensive and useful for swimming-pool heating but are unsuitable for high delivery temperatures.
A useful steady-state energy balance for a flat-plate collector is
Qu = Ac FR [GT(τα)e − UL(Ti − Ta)]
where Qu is useful heat gain in W, Ac collector area in m², FR heat-removal factor, GT incident irradiance in W/m², (τα)e effective transmittance–absorptance product, UL overall loss coefficient in W/(m²·K), Ti inlet-fluid temperature, and Ta ambient temperature. The equation assumes quasi-steady operation and summarizes temperature variation within the collector. Collector efficiency is
ηc = Qu/(Ac GT) = FR[(τα)e − UL(Ti − Ta)/GT]
Efficiency falls as the collector becomes hotter than its surroundings. The useful heat can also be expressed as
Qu = ṁ cp (To − Ti)
where ṁ is mass-flow rate in kg/s, cp specific heat in J/(kg·K), and To outlet temperature. Both equations should give consistent results when the measured flow and temperatures are reliable.
Concentrating solar systems use mirrors or lenses to focus direct normal irradiance. Parabolic troughs, linear Fresnel reflectors, central receivers, and dish systems can achieve higher temperatures than non-concentrating collectors. Their concentration ratio is approximately
C = Aa/Ar
where Aa is aperture area and Ar receiver area. Concentrators require tracking and cannot effectively use diffuse radiation. Optical errors, cosine loss, receiver heat loss, wind, and tracking faults are important design constraints. High-temperature systems may drive a turbine or heat engine, provide industrial process heat, or charge thermal storage.
7. Solar water heating
A domestic solar-water-heating system generally includes collectors, a storage tank, circulation piping, a pump or thermosiphon path, heat exchangers where required, controls, expansion protection, valves, insulation, and an auxiliary heater. Direct systems circulate potable water through collectors; indirect systems circulate a heat-transfer fluid through a heat exchanger and are preferred where freezing or water quality is problematic.
The daily hot-water energy requirement is approximately
QL = mw cp,w(Th − Tc)
where mw is daily water mass, cp,w is water specific heat, and Th and Tc are hot-water and cold-water temperatures. Collector area can be estimated from
Ac = QL fs/(HT ηsys)
where fs is the desired solar fraction, HT daily irradiation on the collector plane, and ηsys an overall useful-system efficiency. This preliminary equation neglects storage dynamics, auxiliary-energy interactions, pipe losses, stagnation, and seasonal variation. Detailed design uses hourly or sub-hourly simulation.
Safety is central. Storage tanks require pressure and temperature relief; potable systems require hygienic control; glycol systems require compatible materials and leak management; and freeze protection must be verified rather than assumed. Excess collector heat can cause stagnation, fluid degradation, or scalding unless the design includes suitable control and heat-dissipation provisions.
8. PV-system design and performance
A grid-connected PV system is designed by matching energy production, electrical limits, site geometry, and load or export constraints. The nominal DC rating is often expressed under standard test conditions, but actual output depends on irradiance, cell temperature, spectrum, soiling, degradation, clipping, and availability.
A first energy estimate is
EAC ≈ PDC,rated HPOA PR
where EAC is AC energy, PDC,rated is rated DC power, HPOA equivalent peak-sun-hours on the plane of array, and PR performance ratio including relevant losses. Units are consistent when power in kW is multiplied by hours to yield kWh.
Worked example. A 20 kW-DC array receives 4.6 peak-sun-hours per day. Assume a performance ratio of 0.78. The estimated daily AC energy is
EAC = 20 × 4.6 × 0.78 = 71.76 kWh/day
The annual estimate, if the stated average applies throughout the year, is approximately 71.76 × 365 = 26,192 kWh/year. In professional design, monthly irradiation and temperature data should replace the annual-average assumption. If the array uses 400 W modules, the module count is 20,000/400 = 50 modules, subject to string-voltage and roof-layout checks.
A complete design checks:
minimum and maximum string voltage over the temperature range;
inverter MPPT voltage window and maximum DC voltage;
current ratings, conductor ampacity, voltage drop, overcurrent protection, and disconnects;
lightning, surge, grounding, bonding, and arc-fault requirements where applicable;
roof loading, wind uplift, fire access, drainage, and maintenance paths;
rapid shutdown or equivalent safety requirements under local codes;
battery charging, thermal management, usable capacity, and reserve policy in hybrid systems.
Battery sizing must distinguish nominal energy from usable energy. If a load requires EL kWh during an outage, battery nominal capacity can be estimated as
Ebat,nom = EL/(ηinv DOD ηbat)
where ηinv is inverter efficiency, DOD allowable depth of discharge, and ηbat battery round-trip or discharge-path efficiency, depending on the defined boundary. Temperature, aging, power limits, and reserve requirements may require additional capacity.
9. Performance, reliability, and maintenance
Useful performance indicators include specific yield, capacity factor, availability, performance ratio, solar fraction, collector efficiency, and levelized cost of energy. Capacity factor for a PV plant is
CF = Eannual/(Prated × 8760 h)
It should not be confused with efficiency: a PV system can have a respectable capacity factor while converting only a fraction of incident solar energy.
Reliability threats include module delamination, corrosion, moisture ingress, junction-box failure, hot spots, connector heating, inverter capacitor aging, tracker wear, pump failure, freeze damage, and hail or wind loading. Reliability engineering should include quality procurement, compatible connectors, correct torque, commissioning tests, thermal inspection, insulation testing, protective-device verification, data logging, preventive maintenance, and condition-based intervention.
Degradation should be represented by a documented rate and warranty boundary rather than an unsupported universal number. Financial models should test degradation, inverter replacement, insurance, curtailment, electricity-price uncertainty, and recycling or disposal costs.
10. Illustrative case: PV and solar hot water for a university workshop
Background. An engineering workshop has a 12 kW average daytime electrical load and a daily hot-water requirement of 1,200 L. The roof can support a south-facing PV array and thermal collectors, but a nearby parapet shades part of the roof in winter.
Problem. The institution wants to reduce grid electricity and gas consumption without compromising safety, teaching access, or future maintenance.
Analysis. A site survey first maps the parapet shadow by month and identifies clear zones for PV strings. The electrical load is concentrated during teaching hours, so direct PV self-consumption is valuable. For water heating, take Th = 60°C, Tc = 15°C, and cp = 4.18 kJ/(kg·K). The daily thermal load is
QL = 1200 × 4.18 × (60 − 15) = 225,720 kJ/day
Since 1 kWh = 3,600 kJ,
QL = 225,720/3,600 ≈ 62.7 kWh/day
If the target solar fraction is 0.55, plane-of-array solar irradiation is 4.5 kWh/m²/day, and the estimated useful system efficiency is 0.45, a preliminary collector area is
Ac = (62.7 × 0.55)/(4.5 × 0.45) ≈ 17.1 m²
A detailed simulation would test storage volume, collector outlet temperature, winter auxiliary demand, summer stagnation, and shading. The PV array is then sized using hourly load and roof constraints rather than simply maximizing roof coverage. Separate MPPT inputs are assigned to strings with materially different shading or orientations.
Approach and solution. The selected concept uses evacuated-tube collectors, an insulated indirect storage tank, a gas or electric auxiliary heater, temperature and pressure relief, freeze protection, and a monitored grid-connected PV array. The parapet zone is excluded from the most sensitive strings. Students receive a commissioning record and monthly performance dashboard as part of the laboratory curriculum.
Outcome. The design reduces both electrical and thermal purchased energy while retaining auxiliary capacity during cloudy periods. The principal benefit is not the nominal rating but the integration of solar-resource analysis, load matching, safety, maintainability, and measurement.
Learning points. Shading must be evaluated geometrically and electrically; thermal sizing must distinguish load from collector output; and a reliable system requires controls, protection, monitoring, and a maintenance plan from the beginning.
11. Challenges, ethics, regulation, and contemporary developments
Solar systems have low operating emissions but are not impact-free. Mining, material processing, manufacturing energy, land occupation, transport, water use for cleaning, battery materials, and end-of-life management should be considered using life-cycle assessment. Siting should protect biodiversity, cultural sites, agricultural priorities, and community interests. Transparent consultation is particularly important for large projects.
Electrical installation must comply with applicable national and local codes, utility interconnection rules, occupational-safety requirements, fire regulations, and pressure-vessel or plumbing standards. Engineers must not treat manufacturer certification as a substitute for code compliance. Designs should provide safe isolation, arc and shock protection, clear labeling, safe access, and emergency procedures.
Current developments include bifacial modules, tandem and perovskite–silicon cells, floating PV, agrivoltaics, digital inspection, advanced forecasting, grid-forming inverters, thermal storage, and integrated PV–heat-pump systems. Artificial intelligence can assist fault detection, irradiance forecasting, image-based soiling assessment, and predictive maintenance. However, models require representative data, validation, cybersecurity controls, human oversight, and an explanation of false-alarm consequences. AI should support engineering judgment, not replace electrical calculations, physical inspection, or statutory responsibility.
Best-practice design workflow
Define load profiles, temperature requirements, reliability targets, budget, and regulatory constraints.
Survey the site, orientation, horizon, structural capacity, access, and shading.
Obtain credible irradiation and temperature data and state the data period and uncertainty.
Select conversion technology and establish thermal or electrical boundaries.
Calculate first-order energy production, then perform time-series simulation.
Check extreme conditions: high and low temperature, high irradiance, snow, wind, stagnation, faults, and outages.
Specify protection, controls, monitoring, commissioning tests, and maintenance.
Evaluate life-cycle cost, environmental effects, embodied impacts, recycling, and community acceptance.
Document assumptions, uncertainty, design margins, and acceptance criteria.
Chapter Summary
Solar-energy engineering begins with the resource: irradiance must be distinguished from irradiation, and beam, diffuse, and reflected components must be evaluated on the actual receiving plane. Solar geometry determines sun position, collector incidence, row spacing, and shading. PV cells convert photon energy through a semiconductor junction; modules and strings combine cells to achieve practical voltage and current, while inverters and MPPT controls condition power for loads or the grid. Thermal collectors use an energy balance in which absorbed radiation is offset by optical and thermal losses. Flat-plate and evacuated-tube collectors are suitable for low- and medium-temperature applications, whereas concentrating systems require direct normal radiation and tracking.
Preliminary PV and hot-water equations are useful for sizing, but professional design requires time-series resource data, electrical-limit checks, safety systems, performance monitoring, and reliability planning. Good solar engineering also considers life-cycle impacts, regulatory compliance, maintainability, cybersecurity, and equitable siting. The best system is therefore not necessarily the one with the largest nameplate capacity; it is the one that reliably matches a defined energy service at acceptable technical, economic, environmental, and social cost.
Key Terms
Solar irradiance: Instantaneous solar power incident on a surface, measured in W/m².
Solar irradiation: Solar energy received per unit area over a period of time.
Beam radiation: Radiation arriving directly from the solar disk.
Diffuse radiation: Radiation scattered by the atmosphere and clouds.
Declination: Angular position of the Sun north or south of the equatorial plane.
Hour angle: Solar angular displacement from local solar noon.
Zenith angle: Angle between the Sun’s rays and the vertical.
Incidence angle: Angle between incoming solar rays and the normal to a receiving surface.
Shading: Obstruction that reduces direct radiation and may cause electrical mismatch.
Photovoltaic cell: Semiconductor device that converts light directly into electricity.
Open-circuit voltage: PV voltage when current is zero.
Short-circuit current: PV current when terminal voltage is zero.
Fill factor: Ratio of maximum-power output to the product of open-circuit voltage and short-circuit current.
Maximum-power-point tracking: Control process that maintains operation near maximum PV power.
Inverter: Power-electronic converter that changes DC electricity into controlled AC electricity.
Flat-plate collector: Non-concentrating thermal collector with an absorber and usually a transparent cover.
Concentrating collector: Solar thermal collector that focuses radiation onto a smaller receiver.
Solar fraction: Portion of a specified thermal load supplied by solar energy.
Performance ratio: Actual PV energy relative to a reference energy after accounting for system losses.
Stagnation: High-temperature condition in a thermal collector when useful heat is not being removed.
Review Questions
5 Short Answer Questions
Distinguish solar irradiance from solar irradiation.
Define solar declination and hour angle.
Why can partial shading reduce PV output by more than the shaded area alone?
State the maximum-power condition using the I–V curve.
Identify two safety provisions required in solar water-heating systems.
5 Long Answer Questions
Explain the components of plane-of-array irradiance and discuss the limitations of an isotropic-sky model.
Describe PV-cell operation, the single-diode model, and the effects of irradiance and temperature.
Compare flat-plate, evacuated-tube, and concentrating solar thermal collectors.
Explain how an inverter and MPPT controller operate in a grid-connected PV system.
Develop a professional workflow for designing and commissioning a reliable rooftop PV system.
3 Analytical / Application Questions
A site at latitude 35° has a solar declination of 20°. Using cos θz = sin φ sin δ + cos φ cos δ cos ω, calculate the solar zenith angle at solar noon and interpret the result.
A hot-water load is 900 L/day, with water heated from 18°C to 55°C. Using cp = 4.18 kJ/(kg·K), calculate the daily thermal energy in kWh and discuss two reasons why actual collector area will exceed an ideal energy-balance estimate.
A PV array has a rated power of 30 kW, receives 5.0 peak-sun-hours per day, and has a performance ratio of 0.75. Estimate daily AC energy and identify three site or design factors that could make the measured value lower.
Multiple Choice Questions with Answers
Question 1
Which quantity is measured in W/m²?
A. Solar irradiance
B. Daily solar irradiation
C. Collector thermal energy
D. Battery capacity
Correct Answer: A. Solar irradiance
Question 2
At solar noon, the hour angle is approximately:
A. −15°
B. 0°
C. 15°
D. 90°
Correct Answer: B. 0°
Question 3
The maximum-power condition for a PV I–V curve is:
A. I = 0
B. V = 0
C. dP/dV = 0
D. dI/dV = 0 in all cases
Correct Answer: C. dP/dV = 0
Question 4
What is the principal function of a bypass diode in a PV module?
A. Increase cell band gap
B. Limit reverse-bias stress in shaded substrings
C. Convert AC to DC
D. Measure solar azimuth
Correct Answer: B. Limit reverse-bias stress in shaded substrings
Question 5
A 10 kW PV array receives 4 peak-sun-hours and has a performance ratio of 0.80. Its estimated daily AC energy is:
A. 8 kWh
B. 32 kWh
C. 40 kWh
D. 50 kWh
Correct Answer: B. 32 kWh
Question 6
Which radiation component is most directly usable by a concentrating solar collector?
A. Diffuse horizontal radiation only
B. Ground-reflected radiation only
C. Direct normal radiation
D. Long-wave terrestrial radiation
Correct Answer: C. Direct normal radiation
Question 7
In a flat-plate collector, increasing inlet-fluid temperature while ambient temperature remains constant generally causes efficiency to:
A. Increase without limit
B. Decrease
C. Remain exactly constant
D. Become independent of irradiance
Correct Answer: B. Decrease
Question 8
The PV power temperature coefficient for a typical silicon module is generally:
A. Positive
B. Negative
C. Exactly zero
D. Equal to the fill factor
Correct Answer: B. Negative
Question 9
A solar water-heating system’s solar fraction is the:
A. Fraction of collector area that is shaded
B. Fraction of thermal load supplied by solar energy
C. Fraction of PV power converted to AC
D. Fraction of water lost by evaporation
Correct Answer: B. Fraction of thermal load supplied by solar energy
Question 10
Which design practice best addresses winter row-to-row shading?
A. Use only annual average ambient temperature
B. Perform a sun-path and seasonal shadow analysis
C. Increase inverter frequency
D. Replace diffuse radiation with zero radiation
Correct Answer: B. Perform a sun-path and seasonal shadow analysis
Renewable & Sustainable Energy Systems
Chapter 4