Thermal, Fluid and Multiphysics Design AnalysisIntroduction and ContextMechanical products rarely operate within a single physical domain. A brake rotor is simultaneously a structural component, a heat-transfer surface and a rotating fluid-flow system. A turbine blade experiences centrifugal stress, conduction, convection, radiation, vibration and oxidation. An electric motor combines electromagnetic losses, heat generation, fluid cooling, thermal expansion and mechanical deformation. Such systems are multiphysics systems: their behaviour is governed by several interacting physical fields. Thermal, fluid and multiphysics design analysis provides the methods needed to predict these interactions before manufacturing. The purpose is not merely to calculate temperature, pressure or stress independently, but to understand how one field changes another. Temperature changes material properties and dimensions; deformation changes flow passages; flow controls heat transfer; heat generation may depend on electrical or mechanical operation; and pressure may produce structural failure. At postgraduate level, the designer must therefore move beyond isolated formula selection. The central tasks are to formulate a physically defensible model, identify dominant mechanisms, select appropriate boundary conditions, verify the numerical solution and interpret uncertainty in relation to design decisions. Learning ObjectivesAfter completing this chapter, the reader should be able to: - Explain the physical coupling among heat transfer, fluid flow and mechanical response.
- Formulate conservation equations for mass, momentum and energy.
- Select suitable analytical, computational-fluid-dynamics (CFD), finite-element and coupled-field methods.
- Estimate heat-transfer coefficients, pressure losses, thermal stresses and thermofluid performance.
- Distinguish one-way, weakly coupled and strongly coupled multiphysics problems.
- Construct and assess a coupled design model, including mesh, time-step and convergence considerations.
- Interpret a thermofluid simulation critically and recognize common modelling errors.
- Apply the concepts to an engineering case involving thermal management and structural integrity.
1. Physical Foundations of Coupled Design1.1 Conservation lawsAll reliable thermofluid models are based on conservation principles. Mass conservation. For a continuum with density ρ and velocity vector u, the differential continuity equation is ∂ρ/∂t + ∇·(ρu) = 0 For incompressible flow with constant density, this reduces to ∇·u = 0 The equation applies when mass is neither created nor destroyed within the control volume. In a one-dimensional steady passage, the mass flow rate is ṁ = ρAu where ṁ is mass flow rate (kg/s), A is cross-sectional area (m²), and u is mean velocity (m/s). Momentum conservation. For a Newtonian fluid, neglecting body forces for simplicity, the momentum equation is ρ(∂u/∂t + u·∇u) = −∇p + μ∇²u where p is pressure (Pa) and μ is dynamic viscosity (Pa·s). The left side represents local and convective acceleration; the right side represents pressure-gradient and viscous forces. Gravity or other body forces must be added when relevant. Energy conservation. A general thermal-fluid energy equation may be expressed as ρcp(∂T/∂t + u·∇T) = ∇·(k∇T) + q̇ where T is temperature (K), cp is specific heat capacity (J/(kg·K)), k is thermal conductivity (W/(m·K)), and q̇ is volumetric heat generation (W/m³). This form assumes constant properties and negligible viscous dissipation. For compressible, high-speed or strongly heated flows, the total-energy equation is more appropriate. 1.2 Modes of heat transferConduction is energy transfer through a temperature gradient. Fourier’s law is q = −kA(dT/dx) where q is heat-transfer rate (W), A is area normal to the heat flow (m²), and x is the conduction coordinate (m). For a plane wall of thickness L with constant k, q = kA(T₁ − T₂)/L Convection transfers energy between a surface and a moving fluid: q = hA(Ts − T_∞) Here h is the convection coefficient (W/(m²·K)), Ts is surface temperature and T∞ is bulk-fluid temperature. Unlike k, h is not generally a material constant; it depends on geometry, velocity, fluid properties and flow regime. Radiation between an opaque surface and large surroundings is approximated by q = εσA(Ts⁴ − Tsur⁴) where ε is emissivity, σ = 5.670 × 10⁻⁸ W/(m²·K⁴) is the Stefan–Boltzmann constant, and absolute temperatures must be used. Radiation becomes particularly important at elevated temperature. 1.3 Thermal resistance networksFor steady one-dimensional heat transfer, conduction and convection can be represented by resistances. A plane-wall conduction resistance is Rcond = L/(kA) and a convection resistance is Rconv = 1/(hA) For series resistances, q = (Thot − Tcold)/ΣR This method assumes steady conditions, one-dimensional heat flow, known and approximately constant properties, and negligible contact-resistance variation. It is valuable for preliminary sizing but cannot replace a field solution when geometry is three-dimensional or local hot spots matter. 2. Fluid-Flow Analysis for Mechanical Design2.1 Flow regimes and dimensionless groupsThe Reynolds number compares inertial and viscous effects: Re = ρuL/μ = uL/ν where L is a characteristic length and ν = μ/ρ is kinematic viscosity (m²/s). Low Reynolds number generally indicates viscous-dominated flow; high Reynolds number indicates stronger inertial effects. The exact transition depends on geometry and disturbances. For internal flow in a smooth circular pipe, transition commonly occurs in the approximate range Re = 2,300–4,000. The Prandtl number compares momentum and thermal diffusivity: Pr = μcp/k = ν/α where α = k/(ρcp) is thermal diffusivity (m²/s). The Nusselt number represents dimensionless convection: Nu = hL/kf where kf is fluid thermal conductivity. The pressure-loss coefficient is K = Δp/(ρu²/2) and the Darcy friction factor for fully developed pipe flow is related to pressure loss by Δp = fD(L/D)(ρu²/2) where D is pipe diameter and fD is the Darcy friction factor. Confusing Darcy and Fanning friction factors produces a factor-of-four error because fD = 4fF. The Biot number is important in transient thermal analysis: Bi = hLc/ks where Lc is a characteristic solid length and ks is solid conductivity. If Bi < approximately 0.1, internal conduction resistance is small relative to surface convection and the lumped-capacitance approximation may be acceptable. This criterion must be applied with an appropriate characteristic length, often volume-to-surface-area ratio. 2.2 Internal-flow designFor a uniform pipe, the total pressure loss includes distributed and local losses: Δptotal = [fD(L/D) + ΣK]ρu²/2 The equation assumes incompressible flow and uses a consistent velocity reference for the local-loss coefficients. Pump power required to deliver volumetric flow rate Q is Ppump = Δptotal Q/ηp where ηp is pump efficiency. In actual systems, elevation change and changes in kinetic energy may also be included through the mechanical-energy equation. For turbulent flow in a smooth pipe, the Blasius approximation fD ≈ 0.3164 Re^(−0.25) is useful approximately for 4,000 ≲ Re ≲ 10⁵. For rough or broader turbulent conditions, the Colebrook–White relation is more appropriate: 1/√fD = −2 log₁₀[(εr/3.7D) + 2.51/(Re√fD)] where εr is absolute roughness. The equation is implicit and is normally solved iteratively or with a validated explicit approximation. 2.3 External flow and separationIn external flow, drag and lift are commonly expressed as FD = CD(ρu²A/2) and FL = CL(ρu²A/2) where CD and CL are dimensionless coefficients. Their values depend on Reynolds number, surface roughness, geometry and, when relevant, Mach number. Flow separation generates wakes, pressure drag and unsteady loads. A design based only on inviscid pressure distribution may therefore be unsafe or inefficient. 3. Thermal Stress and Thermomechanical BehaviourA temperature field produces thermal strain even when no external force is applied. For isotropic material under uniform temperature change, εth = αT∆T where αT is the coefficient of thermal expansion (K⁻¹) and ΔT is temperature change (K). If expansion is completely restrained in a simple uniaxial elastic member, the induced stress is approximately σth = EαT∆T where E is Young’s modulus (Pa). This expression is a special case: it assumes linear elasticity, uniform temperature, complete restraint, small strain and temperature-independent properties. In three-dimensional constrained structures, the stress state must be obtained from compatibility and constitutive equations. For isotropic linear thermoelasticity, σ = C : (ε − εth) where σ is the stress tensor, ε is total strain, εth is the thermal-strain tensor and C is the fourth-order elastic stiffness tensor. For isotropic materials, εth = αTΔT I, with I denoting the identity tensor. Thermal gradients are often more critical than mean temperature. A thin plate heated uniformly may expand with little stress if unconstrained, whereas a thick plate with a hot surface and cold interior develops bending and membrane stresses. At high temperature, creep, plasticity, temperature-dependent strength and oxidation must be considered. Elastic thermal-stress calculations are then only an initial screening tool. 4. Multiphysics Coupling Strategies4.1 One-way and two-way couplingIn one-way coupling, one field affects another, but the second field does not significantly alter the first. For example, a CFD solution may determine convection coefficients, which are then transferred to a structural thermal model. This is efficient when deformation is small and temperature does not appreciably change flow properties. In two-way coupling, fields influence one another. A heated flexible wall changes density and viscosity, which alters the flow; the changed flow modifies heat transfer; the new temperature field changes wall deformation. Strong two-way coupling requires simultaneous or iteratively exchanged solutions. Typical couplings include: | Coupled fields | Mechanism | Example |
|---|
| Fluid–thermal | Advection and convection | Cooling channel | | Thermal–structural | Expansion and temperature-dependent stiffness | Turbine casing | | Fluid–structural | Pressure loading and deformation | Flexible valve | | Electromagnetic–thermal | Joule or magnetic losses | Motor winding | | Rotordynamic–thermal | Frictional heat and clearances | Bearing | | Chemical–thermal–fluid | Reaction heat and species transport | Combustor |
4.2 Governing model hierarchyA useful design model is not necessarily the most detailed model. A hierarchy may include: - Hand calculations and resistance networks for feasibility.
- One-dimensional network models for flow distribution and system pressure loss.
- Reduced-order thermal models for control and optimization.
- Steady RANS CFD for average turbulent flow performance.
- Transient CFD, LES or DNS for unsteady phenomena when justified.
- Finite-element thermal and structural analysis for local temperature and stress.
- Fully coupled multiphysics analysis for strong feedback.
The model should be selected according to the design question, required accuracy, available data and computational cost. A high-fidelity model with uncertain boundary conditions may be less reliable than a simpler model with well-characterized inputs. 4.3 Boundary conditions and interfacesBoundary conditions frequently dominate the result. Thermal boundaries may be prescribed temperature, heat flux, convection, radiation or conjugate fluid–solid heat transfer. Fluid boundaries may specify velocity, mass flow, pressure, turbulence quantities or wall conditions. Structural boundaries must represent actual supports, contacts, bolt preload and symmetry. At a fluid–solid interface, temperature and heat flux continuity require Tf = Ts and −kf∇Tf·n = −ks∇Ts·n where n is the interface normal. If a contact resistance exists, the temperature jump may be approximated by q'' = (T1 − T2)/R''c where Rc″ is contact thermal resistance per unit area (m²·K/W). Assuming perfect contact when an interface is rough, bolted or separated by an imperfect layer can substantially underpredict temperature. 5. Numerical Methods and Verification5.1 DiscretizationFinite-volume methods integrate conservation equations over control volumes and naturally preserve flux balances. Finite-element methods approximate field variables using shape functions and are especially effective for complex structural and coupled-field domains. Finite-difference methods are conceptually simple but less flexible for irregular geometry. A mesh must resolve physical length scales: boundary layers, thermal gradients, wakes, contact regions and stress concentrations. Refining the mesh globally is inefficient if the important gradients are local. Inflation or boundary-layer meshes are usually needed for wall-bounded CFD, while local refinement is essential near fillets, holes and interfaces in structural models. 5.2 Convergence and verificationA residual reduction alone does not establish correctness. A credible analysis should examine: - conservation imbalance of mass, momentum and energy;
- monitored engineering quantities such as pressure drop, outlet temperature and maximum stress;
- mesh independence;
- time-step independence for transient problems;
- sensitivity to turbulence, material and boundary-condition models;
- comparison with analytical solutions, experiments or benchmark problems.
For a computed quantity φ at successive mesh sizes, a grid-convergence study can estimate whether the result approaches a limiting value. The formal order of accuracy is useful, but practical convergence may be limited by modelling error and geometric approximation. 5.3 Uncertainty and validationVerification asks, “Was the equation solved correctly?” Validation asks, “Does the model represent reality adequately?” Sources of uncertainty include material properties, roughness, turbulence closure, contact conductance, sensor error, manufacturing variation and operating conditions. For design decisions, reporting a single value without uncertainty is misleading. A maximum temperature of 180 °C may be acceptable if the limit is 200 °C, but not if combined modelling and measurement uncertainty is ±30 °C. Sensitivity analysis identifies influential variables and supports robust design. 6. Worked Example: Cooling of a Heated WallA flat electronic module dissipates 120 W through a surface of area 0.020 m². Cooling air has a bulk temperature of 25 °C, and the estimated convection coefficient is 35 W/(m²·K). The wall is aluminium, 4 mm thick, with thermal conductivity 180 W/(m·K). The rear surface is assumed adiabatic, and radiation is neglected. Estimate the surface temperature and check whether lumped conduction through the wall is important. The convection resistance is Rconv = 1/(hA) = 1/[35 × 0.020] = 1.429 K/W The temperature rise across the convection boundary is ∆Tconv = qRconv = 120 × 1.429 = 171.5 K Therefore, Ts = 25 + 171.5 ≈ 196.5 °C The wall conduction resistance is Rcond = L/(kA) = 0.004/(180 × 0.020) = 0.00111 K/W Its temperature drop is only ∆Tcond = 120 × 0.00111 ≈ 0.13 K Thus, under the stated assumptions, convection dominates the thermal resistance. The result also exposes a design issue: the predicted surface temperature is high. Increasing area, increasing airflow, using fins or employing liquid cooling would be more effective than modestly increasing the aluminium conductivity. Radiation, which has been neglected, would reduce the actual temperature somewhat, but it should be included in a final design if the surface is hot and exposed. 7. Applied Case: Thermal Management of a High-Speed Electric-Motor HousingBackgroundConsider an illustrative design case involving a 75 kW permanent-magnet motor for an industrial vehicle. Copper, iron and mechanical losses produce approximately 6 kW of heat at peak operation. The motor must operate for 20 minutes without exceeding a winding temperature of 155 °C, while the housing must remain below a specified touch-temperature limit. Problem definitionThe motor includes a water jacket around the cylindrical housing. The design team must determine whether the proposed jacket provides sufficient cooling without excessive pumping power or unacceptable thermal stress. The main uncertainties are the distribution of heat among the windings, stator and rotor, the thermal contact between stator and housing, and the local flow distribution in the jacket. Analysis approachA staged analysis is appropriate: - Use loss estimates from electromagnetic and mechanical models to define volumetric heat sources.
- Construct a lumped thermal network to estimate winding, stator and housing temperatures.
- Solve the jacket flow to obtain mass-flow distribution and pressure drop.
- Perform conjugate heat-transfer CFD for the fluid and housing.
- Transfer the transient temperature field to a structural model.
- Evaluate thermal expansion, bolt loads, bearing alignment and fatigue-sensitive regions.
- Validate predicted coolant temperature rise and housing temperatures using instrumented testing.
For a coolant stream, the energy balance is Q̇ = ṁcp(Tout − Tin) If 6 kW were removed by water with cp = 4,180 J/(kg·K), and a permitted coolant rise of 10 K were selected, the required mass flow would be ṁ = Q̇/[cp∆T] = 6000/(4180 × 10) ≈ 0.144 kg/s This is an idealized average requirement. It does not guarantee adequate local cooling because hot spots depend on contact conductance, circumferential flow distribution and local heat flux. Suppose the jacket CFD model predicts a pressure drop of 35 kPa at this flow rate and pump efficiency is 60%. With Q ≈ ṁ/ρ ≈ 1.44 × 10⁻⁴ m³/s for water of density approximately 1,000 kg/m³, Ppump = ∆pQ/ηp = 35,000 × 1.44×10^(−4)/0.60 ≈ 8.4 W The pumping power is small compared with motor output, but this estimate must be checked against the full circuit, including fittings, heat exchanger and control-valve losses. Solution and interpretationThe coupled model identifies a hot region near the end-winding connections where the local thermal resistance is high. Increasing average coolant flow produces limited improvement because the controlling resistance is between the copper winding and the housing. The design is therefore changed by improving impregnation, adding a thermally conductive interface material and modifying the end-winding support. A moderate jacket-flow increase is retained to reduce housing temperature, but it is not used as the sole remedy. The structural analysis predicts thermal expansion of the housing and a small reduction in bearing alignment. A revised support arrangement permits radial expansion while maintaining axial location. Fatigue assessment uses the combined mechanical and thermally induced stress range rather than the mechanical load alone. OutcomeThe final design satisfies the winding-temperature target in the validated duty cycle, reduces the predicted peak thermal stress and maintains acceptable pumping power. Testing shows that the original model underpredicted interface resistance; updating the model improves agreement with measured temperatures. Learning points- Average heat-removal capacity does not establish local temperature safety.
- Contact resistance and heat-source distribution can dominate results.
- Thermal deformation may affect alignment and clearance even when stresses are below yield.
- Validation should include temperatures, flow rate and pressure drop rather than a single measurement.
- Design changes should target the dominant resistance or coupling mechanism, not merely increase an easily controlled variable.
8. Practical Design WorkflowA disciplined workflow is as follows: Define the question. Is the objective maximum temperature, pressure loss, fatigue life, efficiency, noise, reliability or all of these? Identify physics. Include only mechanisms that can affect the decision, but justify exclusions such as radiation, compressibility, turbulence or contact resistance. Estimate scales. Calculate Reynolds, Prandtl, Biot, Mach and Fourier numbers where relevant. Estimate characteristic times, temperature differences and deformation magnitudes. Build a reduced model. Use balances and resistance networks to establish expected magnitudes and detect implausible simulation results. Create the numerical model. Use appropriate geometry, material data, boundary conditions, interfaces and solver settings. Verify. Check conservation, mesh and time-step sensitivity, and limiting cases. Validate. Compare with experiments, published correlations or trusted benchmark solutions. Assess uncertainty. Vary uncertain inputs and report ranges or confidence bounds where possible. Make the design decision. Compare alternatives using performance, safety, manufacturing, maintenance, cost and environmental criteria. 9. Limitations, Governance and Emerging PracticeThermofluid simulations can create false confidence. Common errors include prescribing an unrealistically uniform heat-transfer coefficient, using an outlet pressure that conflicts with the physical system, neglecting radiation at high temperature, treating turbulent flow as laminar for convenience, over-constraining structural supports and interpreting a singular peak stress at a sharp corner as a physical failure prediction. Engineering governance requires traceable assumptions, version-controlled models, documented material data, independent review and configuration control. Safety-critical applications may require compliance with sector standards, certified software procedures, design margins and experimental qualification. AI-assisted surrogate models and optimization can accelerate design exploration, but they do not remove the need for conservation-law checks, validation and human responsibility. A machine-learning model trained on narrow operating data may fail under transients, fouling, degradation or geometry changes. Contemporary developments include conjugate heat-transfer solvers, immersed-boundary methods, reduced-order models, topology optimization with thermal and fluid constraints, digital twins and uncertainty-aware design optimization. Additive manufacturing enables lattice heat exchangers and conformal cooling channels, but introduces roughness, anisotropy, porosity and inspection challenges. Sustainable design increasingly evaluates not only peak performance but also pumping energy, refrigerant or coolant selection, material use, repairability and end-of-life impacts. Chapter SummaryThermal, fluid and multiphysics design analysis treats mechanical products as interacting physical systems rather than isolated components. Conservation of mass, momentum and energy provides the governing foundation. Dimensionless groups such as Reynolds, Prandtl, Nusselt and Biot numbers support model selection and scaling. Thermal resistance methods are effective for preliminary estimates, while CFD, finite-element analysis and conjugate-field methods resolve complex spatial behaviour. Temperature fields produce expansion and, when constrained or nonuniform, thermal stress. Coupling may be one-way or strongly two-way, and the correct level of fidelity depends on the design question and uncertainty in the inputs. Credible analysis requires appropriate boundary conditions, interface treatment, mesh and time-step studies, conservation checks, validation and uncertainty assessment. In practice, the best design targets dominant thermal resistances and feedback mechanisms while balancing performance, reliability, manufacturability, energy use and safety. Key TermsAdvection: Transport of a quantity by bulk fluid motion. Biot number: Ratio of internal conduction resistance to surface convection resistance. Conjugate heat transfer: Simultaneous solution of heat transfer in a fluid and an adjoining solid. Convection: Heat transfer between a surface and a moving fluid. Coupled-field analysis: Analysis in which two or more physical fields interact. Friction factor: Dimensionless measure used to calculate distributed pipe-flow pressure loss. Heat flux: Heat-transfer rate per unit area, measured in W/m². Nusselt number: Dimensionless measure of convective heat transfer. Prandtl number: Ratio of momentum diffusivity to thermal diffusivity. Radiation: Electromagnetic thermal-energy transfer, often proportional to absolute temperature to the fourth power. Reynolds number: Ratio of inertial to viscous effects in fluid flow. Thermal contact resistance: Resistance to heat flow across an imperfect interface. Thermal conductivity: Material property describing conductive heat-transfer capability. Thermal expansion: Dimensional change caused by temperature change. Thermal stress: Stress generated by constrained or nonuniform thermal expansion. Turbulence model: Mathematical closure used to represent unresolved turbulent motions. Verification: Demonstration that equations have been implemented and solved correctly. Validation: Demonstration that a model adequately represents the physical system. Review QuestionsShort Answer Questions- What physical mechanisms are represented by the mass, momentum and energy conservation equations?
- Distinguish between one-way and two-way multiphysics coupling.
- Define Reynolds number and explain its significance in flow analysis.
- Under what condition may lumped-capacitance thermal analysis be appropriate?
- Why can thermal gradients be more important than average temperature in structural design?
Long Answer Questions- Explain how a conjugate heat-transfer model is formulated at a fluid–solid interface, including the required continuity conditions.
- Discuss the assumptions, benefits and limitations of thermal resistance networks compared with numerical field methods.
- Describe a rigorous CFD and finite-element verification and validation strategy for a cooled mechanical component.
- Explain the sources of thermally induced stress in a constrained three-dimensional structure and discuss when elastic analysis becomes inadequate.
- Develop a multidisciplinary workflow for designing a high-temperature rotating component exposed to internal cooling flow.
Analytical / Application Questions- A coolant removes 4.5 kW with a mass flow rate of 0.10 kg/s and specific heat capacity of 4,000 J/(kg·K). Calculate the coolant temperature rise and state the assumptions in using the steady energy balance.
- A pipe has Re = 20,000 and relative roughness sufficiently small for the Blasius approximation. Estimate the Darcy friction factor and explain why the approximation should not be used indiscriminately outside its stated range.
- A steel bracket with αT = 12 × 10⁻⁶ K⁻¹, E = 200 GPa and a uniform temperature rise of 80 K is completely restrained in one direction. Estimate the idealized thermal stress and discuss at least three reasons why the actual stress may differ.
Multiple Choice Questions with AnswersQuestion 1Which equation represents mass conservation for an incompressible fluid? A. ∇·u = 0 B. ∇×u = 0 C. ρcp∂T/∂t = q̇ D. σ = Eε Correct Answer: A. ∇·u = 0 Question 2The Reynolds number primarily compares which effects? A. Radiative and conductive effects B. Inertial and viscous effects C. Elastic and plastic effects D. Pressure and temperature effects Correct Answer: B. Inertial and viscous effects Question 3For a plane wall with constant conductivity, which expression gives conduction resistance? A. R = hA B. R = kA/L C. R = L/(kA) D. R = ρu²/2 Correct Answer: C. R = L/(kA) Question 4A coolant removes 4,000 W at 0.20 kg/s with cp = 4,000 J/(kg·K). What is its temperature rise? A. 2 K B. 5 K C. 20 K D. 80 K Correct Answer: B. 5 K Question 5The Biot number compares A. Inertial force to viscous force B. Momentum diffusivity to thermal diffusivity C. Internal conduction resistance to surface convection resistance D. Pressure loss to pumping power Correct Answer: C. Internal conduction resistance to surface convection resistance Question 6Which condition is required at an ideal fluid–solid thermal interface? A. Equal pressure and zero heat flux B. Equal temperature and continuous normal heat flux C. Equal velocity and equal density D. Zero temperature and equal viscosity Correct Answer: B. Equal temperature and continuous normal heat flux Question 7In a fully restrained, uniform, linear-elastic member, idealized thermal stress is A. σ = EαT∆T B. σ = hA∆T C. σ = ρu²/2 D. σ = kA/L Correct Answer: A. σ = EαT∆T Question 8Which statement best distinguishes validation from verification? A. Validation checks coding; verification checks experiments B. Validation checks physical adequacy; verification checks solution implementation C. They are identical activities D. Validation concerns only mesh size Correct Answer: B. Validation checks physical adequacy; verification checks solution implementation Question 9For a pump delivering volumetric flow rate Q against pressure difference Δp, the ideal hydraulic power is A. ∆p/Q B. ∆pQ C. Q/∆p D. ρQ² Correct Answer: B. ∆pQ Question 10Which design change directly targets a high thermal contact resistance between a winding and housing? A. Reducing coolant density only B. Improving the thermal interface or impregnation C. Increasing structural restraint D. Reducing the measurement frequency Correct Answer: B. Improving the thermal interface or impregnation
|