Introduction to Mechatronics Systems

Chapter 6
Actuators, Drives and Power Systems

Bachelor Program in Mechatronics Engineering
Introduction to Mechatronics Systems   •   Bachelor

Actuators, Drives and Power Systems

Introduction

A mechatronic system converts information into physical action. Sensors measure variables, controllers compute decisions, and actuators produce force, torque, displacement, flow, heat, or another physical effect. The actuator is therefore the energy-conversion interface between a control system and the mechanical process. Its performance depends not only on the actuator itself but also on the drive, power converter, transmission, energy source, control algorithm, thermal environment, and safety system.

For example, a robotic joint may use a permanent-magnet synchronous motor, an inverter, a gearbox, an encoder, a brake, and a DC-link power supply. A pneumatic pick-and-place machine may use a compressor, valves, cylinders, flow controls, and pressure regulators. Selecting an actuator is consequently a system-design problem rather than a simple comparison of catalogue ratings.

This chapter examines electric, pneumatic, hydraulic, thermal, and smart-material actuators; introduces drive and power-electronic principles; develops basic sizing equations; and evaluates efficiency, transmission, operating constraints, safety, and contemporary design practice.

Learning Objectives

By the end of this chapter, students should be able to:

  1. Explain the energy-conversion principles of major actuator families.
  2. Compare actuator technologies using performance, cost, control, safety, and environmental criteria.
  3. Calculate approximate motor torque, speed, power, and drive requirements.
  4. Explain the functions of power converters, motor drives, transmissions, and protection systems.
  5. Evaluate efficiency, duty cycle, thermal limits, regeneration, and operating constraints.
  6. Propose and justify an actuator subsystem for a practical mechatronic application.

1. Actuators as Energy-Conversion Elements

An actuator receives an input energy or control signal and produces a controlled physical output. Important outputs include:

  • rotational torque and speed;
  • linear force and velocity;
  • fluid pressure and flow;
  • temperature or heat flow;
  • strain, displacement, or vibration.

The control signal does not usually supply the main energy. A low-power controller commands a power stage that draws energy from an electrical, pneumatic, hydraulic, or thermal source. This distinction is central to safe and reliable design.

For rotational motion, mechanical power is

Pmech = Tω

where Pmech is mechanical power in watts, T is torque in newton-metres, and ω is angular velocity in radians per second. Since radians are dimensionless, the units are N·m/s, equivalent to watts. If speed is specified in revolutions per minute, n, then

ω = 2πn/60

For linear motion,

Pmech = Fv

where F is force in newtons and v is linear velocity in metres per second. These equations describe useful mechanical output; losses in the actuator and transmission require a larger input power.

A general efficiency definition is

η = Pout/Pin

where η is efficiency, Pout is useful output power, and Pin is input power. For passive losses and ordinary operating conditions, 0 < η < 1. Efficiency varies with speed, load, temperature, pressure, switching frequency, and operating point.

Dynamic requirements

Static load calculations are insufficient when acceleration matters. For a rigid rotating body,

T = Jα + Tload + Tfriction

where J is total reflected moment of inertia in kg·m², α is angular acceleration in rad/s², Tload is external resisting torque, and Tfriction is friction torque. The equation assumes a rigid body and a one-dimensional rotational model. Gravity torque, disturbance torque, and gearbox effects may need to be added explicitly.

For translation,

F = ma + Fload + Ffriction + Fgravity

where m is moving mass and a is linear acceleration. On a slope, the gravity component is mg sin θ, with θ measured from the horizontal. Vertical lifting has a gravity force of mg.

2. Electric Actuators

Electric actuators are widely used because electrical energy is readily distributed, control is precise, and electronic drives can regulate torque, speed, and position rapidly. Common types include brushed DC motors, brushless DC motors, permanent-magnet synchronous motors, induction motors, stepper motors, and solenoids.

2.1 Brushed DC motors

A brushed DC motor uses a commutator and brushes to switch current in the rotor winding. Its approximate steady-state relationships are

T = kT I

and

e = keω

where T is electromagnetic torque, I is armature current, kT is torque constant, e is back electromotive force, ke is back-emf constant, and ω is angular speed. In coherent SI units, the numerical values of kT and ke are closely related, although their units differ.

The armature voltage equation is

V = RI + L(dI/dt) + keω

where V is applied voltage, R is winding resistance, and L is inductance. This model neglects brush voltage variation and magnetic saturation. Brushed motors are inexpensive and easy to control, but brush wear, electrical noise, and limited high-speed life are disadvantages.

2.2 Brushless and synchronous motors

Brushless DC and permanent-magnet synchronous motors replace mechanical commutation with electronic commutation. Rotor magnets provide the field, while an inverter controls stator currents. These motors offer high power density, efficiency, and reliability. They require rotor-position information or sensorless estimation and careful control of current and commutation.

A field-oriented controller resolves three-phase currents into torque-producing and flux-producing components. In simplified operation, torque is primarily controlled by the q-axis current. This permits smooth operation and rapid torque response, but increases software, sensing, and inverter complexity.

2.3 Induction motors

Induction motors produce rotor current through electromagnetic induction and do not require permanent magnets. They are robust, economical, and common in pumps, fans, compressors, and industrial machines. Variable-frequency drives control their voltage and frequency. Their disadvantages include lower power density than many permanent-magnet motors and more complicated control when high dynamic performance is required.

2.4 Stepper motors and solenoids

A stepper motor moves in discrete angular increments. It is useful for moderate-speed positioning where open-loop operation is acceptable. However, missed steps can occur if commanded acceleration or load torque exceeds the available torque. Microstepping improves smoothness but does not necessarily increase maximum static torque.

A solenoid produces linear motion by electromagnetic attraction. It is appropriate for latching, switching, and short-stroke mechanisms, but its force varies strongly with air gap and coil temperature. Continuous operation may require thermal derating.

3. Pneumatic Actuators

Pneumatic systems use compressed air to create force and motion. Their principal components are a compressor, receiver, filter, regulator, lubricator where appropriate, directional valve, flow-control valve, actuator, and exhaust system.

For an ideal pressure-driven piston, the extension force is approximately

F = pA

where p is gauge pressure acting across the piston and A is effective piston area. During retraction of a single-rod cylinder, the effective area is

Aret = π(D² - d²)/4

where D is bore diameter and d is rod diameter. Actual force is lower because of seal friction, pressure losses, leakage, and acceleration. A design calculation therefore uses a force efficiency or safety factor.

Pneumatics are clean at the point of use, relatively inexpensive, fast, and tolerant of overload. Air compressibility provides compliance, which can be advantageous in gripping but reduces positional stiffness. Compressors and leaks make pneumatic systems energetically inefficient for many applications. Exhaust noise, moisture, pressure hazards, and variable force with pressure are important constraints.

Pneumatic cylinders are excellent for two-position or limited-position motion. Servo-pneumatic systems can achieve intermediate positioning, but require proportional valves, position feedback, and sophisticated control because of air compressibility and friction.

4. Hydraulic Actuators

Hydraulic systems use pressurized liquid, usually oil, to transmit power. A hydraulic cylinder produces force approximately equal to pressure multiplied by effective area. A hydraulic motor produces torque related to pressure difference and displacement per revolution. Hydraulic power is

Phyd = pQ

where p is pressure in pascals and Q is volumetric flow rate in cubic metres per second. The product has units of watts.

Hydraulics provide very high force and power density, smooth motion, and good overload capability. They are used in mobile machinery, presses, aircraft systems, injection moulding, and heavy automation. Limitations include leakage, contamination sensitivity, pump noise, heat generation, fire or environmental risk from fluids, and more demanding maintenance.

A pressure-relief valve is essential because it limits excessive system pressure. Filtration, correct hose ratings, guarding against injection injuries, and safe energy isolation are mandatory professional practices. Hydraulic accumulators store hazardous energy and must be depressurized before maintenance.

5. Thermal and Smart-Material Actuators

5.1 Thermal actuators

Thermal actuators create motion through heating, expansion, phase change, or temperature-dependent pressure. Examples include bimetallic strips, wax motors, thermostatic elements, and shape-memory alloys. Their advantages include simplicity and high force for compact devices. Their major limitations are slow response, heat transfer delay, hysteresis, and difficulty removing heat.

For a uniform material undergoing free thermal expansion,

∆L = αL0∆T

where ∆L is change in length, α is the coefficient of thermal expansion in K⁻¹, L0 is original length, and ∆T is temperature change in kelvins or degrees Celsius for a temperature difference. The equation assumes small strain and uniform temperature.

If expansion is fully constrained, thermal stress may be approximated by

σ = Eα∆T

where σ is stress and E is Young’s modulus. This ideal relation neglects plasticity, creep, temperature-dependent properties, and partial constraint.

5.2 Shape-memory alloys

Shape-memory alloys, such as nickel–titanium, can recover a programmed shape when heated through a transformation range. They are compact and nearly silent, but generally have modest bandwidth, limited cycle life under high strain, and significant thermal-management requirements. They are useful in miniature valves, medical devices, adaptive structures, and compact latches.

5.3 Piezoelectric and electroactive materials

Piezoelectric actuators deform when an electric field is applied. They provide extremely fine displacement, high stiffness, and high bandwidth, but usually small stroke. Mechanical amplifiers or flexures can increase stroke while reducing force and bandwidth. Hysteresis, creep, insulation requirements, and fracture sensitivity must be considered.

6. Comparing Actuator Technologies

CriterionElectricPneumaticHydraulicThermalSmart material
Control precisionHighLow to highMedium to highLow to mediumHigh for small motion
Power densityMedium to highMediumVery highMediumHigh in niche uses
Response speedHighHighHighLowLow to high, technology-dependent
CleanlinessHighHigh at point of useFluid-dependentHighHigh
Energy efficiencyHigh to very highOften low at system levelMediumOften lowApplication-dependent
MaintenanceLow to mediumMediumHighLowLow to medium
Overload toleranceLimited thermallyGoodGood with relief systemLimited thermallyCycle-dependent
Typical strengthPrecise programmable motionFast simple motionLarge forceCompact thermal motionSmall precise or adaptive motion

No technology is universally superior. Selection should begin with required force or torque, stroke, speed, acceleration, accuracy, duty cycle, environment, available energy, safety requirements, lifecycle cost, and maintenance capability.

7. Motor and Drive Sizing

7.1 Torque and speed

Suppose a motor drives a load through a reduction gearbox with ratio

i = ωm/ωL

where ωm is motor speed and ωL is load speed. For an ideal gearbox, load torque is multiplied by the ratio. With gearbox efficiency ηg, the motor torque required for a resisting load torque TL is

Tm = TL/(iηg)

when i > 1 denotes speed reduction. The load inertia reflected to the motor is

Jref = JL/i²

where JL is load inertia. This relation assumes an ideal rigid ratio and neglects gearbox inertia and compliance.

The motor must satisfy both peak and continuous requirements. Peak torque is associated with acceleration, transient loads, and disturbances. Continuous or root-mean-square torque is associated with heating. For a periodic duty cycle with constant torque segments,

Trms = √[(Σ Tk²tk)/(Σ tk)]

where Tk is torque during segment k and tk is its duration. This approximation is useful when copper loss is proportional to torque squared and motor cooling conditions are reasonably constant.

Worked Example 1: Gearbox and acceleration

An actuator must accelerate a load inertia of 0.18 kg·m² from rest to 120 rpm in 0.40 s. A gearbox has ratio i = 6 and efficiency ηg = 0.90. Ignore external load torque and motor inertia.

First, convert load speed:

ωL = 2π(120)/60 = 12.57 rad/s

The angular acceleration is

αL = 12.57/0.40 = 31.42 rad/s²

Load acceleration torque is

TL = JLαL = 0.18×31.42 = 5.65 N·m

The motor speed is six times the load speed, while the motor torque is

Tm = 5.65/(6×0.90) = 1.05 N·m

The motor must therefore supply at least 1.05 N·m during the idealized acceleration. A practical selection adds a margin for friction, uncertainty, thermal conditions, and transient overload. The motor speed at the target load speed is 720 rpm.

7.2 Electrical and thermal sizing

For a DC link or low-voltage motor, approximate electrical input power is

Pin = VI

where V is voltage and I is current. In a real drive, converter losses, motor copper loss, iron loss, mechanical friction, and switching loss make the actual input power greater than useful mechanical power.

Motor ratings must be checked against:

  • peak current and peak torque;
  • continuous current and thermal dissipation;
  • speed limit and back-emf;
  • voltage margin at maximum speed;
  • regenerative energy during deceleration;
  • ambient temperature and enclosure cooling;
  • bearing, insulation, and gearbox limits.

A motor that meets peak torque but overheats under continuous duty is incorrectly sized. Conversely, a large motor operated far below its efficient region may increase cost and reduce system efficiency.

8. Drives and Power Electronics

A drive is the controlled power interface between a source and an actuator. It may include rectifiers, DC-link capacitors, choppers, inverters, switching devices, current sensors, gate drivers, feedback circuits, and protective functions.

8.1 DC motor drive

A DC motor can be controlled by varying armature voltage, commonly using pulse-width modulation (PWM). For an ideal buck converter in continuous conduction,

Vavg ≈ DVdc

where D is duty ratio between 0 and 1 and Vdc is supply voltage. This simplified relation assumes ideal switches, negligible ripple effects, and operation within the converter’s voltage range.

8.2 Inverters and AC drives

An inverter synthesizes variable-frequency and variable-amplitude AC from a DC link. Three-phase voltage-source inverters use six controlled switches, commonly insulated-gate bipolar transistors or silicon-carbide MOSFETs, arranged in three half-bridges. PWM controls the fundamental voltage while limiting current ripple.

Induction-motor drives often use volts-per-hertz control for basic applications or vector control for improved torque response. Permanent-magnet motors commonly use sinusoidal current control and field-oriented control. The selected method depends on cost, dynamic performance, speed range, and available feedback.

8.3 Regeneration and braking

When a motor decelerates, mechanical energy can flow back through the drive. If the DC link cannot return energy to the source, the voltage rises. A braking resistor and chopper may dissipate the energy as heat; an active front end may return it to the electrical supply; or a battery or supercapacitor may absorb it.

For a decelerating inertia, the recoverable kinetic energy is

Ek = ½Jω²

where Ek is rotational kinetic energy. The practical recovered energy is lower because of motor, inverter, transmission, and storage losses.

8.4 Protection and electromagnetic compatibility

Power systems require overcurrent, short-circuit, overvoltage, undervoltage, overtemperature, ground-fault, and loss-of-feedback protection as appropriate. Fuses and circuit breakers protect wiring and equipment but do not replace control-system safety functions. EMC design includes shielding, grounding, filtering, controlled switching edges, physical separation of power and signal wiring, and correct cable termination.

9. Mechanical Transmission

Transmission elements adapt actuator speed, torque, force, and motion. Gears provide precise ratios and high torque density. Belts are quiet and tolerate misalignment but may stretch or slip. Lead screws provide high force and can be self-locking, but often have lower efficiency than ball screws. Ball screws are efficient and precise but may back-drive. Rack-and-pinion systems convert rotation to translation over long travel. Harmonic and planetary gearboxes offer high ratio and compact packaging, with trade-offs in efficiency, backlash, stiffness, cost, and life.

Transmission compliance affects control bandwidth. Elastic shafts and belts can create resonances, while backlash produces dead zones and positioning error. A controller designed using only rigid-body assumptions may become unstable when flexible modes are present. Mechanical stiffness, damping, sensor location, and load inertia must therefore be considered together with the drive controller.

10. Operating Constraints and System Evaluation

Duty cycle

Actuator selection must distinguish continuous, intermittent, peak, and standby operation. A duty cycle with frequent acceleration may be limited by peak current, while a long holding period may be limited by thermal loss. Holding a vertical load electrically can consume power continuously; a brake, counterbalance, or self-locking transmission may reduce energy use, subject to safety analysis.

Environment

Temperature, dust, moisture, corrosive chemicals, vibration, radiation, altitude, and explosive atmospheres influence actuator selection. Pneumatic equipment may be preferred in some hazardous areas, while electrical equipment requires suitable ingress protection and explosion-rated certification. Hydraulic fluids may be unacceptable in food or medical environments unless an approved fluid and containment strategy are used.

Safety

Stored electrical, pneumatic, hydraulic, gravitational, and thermal energy can injure personnel. Safe design includes guarding, emergency stopping, safe torque-off where applicable, pressure relief, isolation and lockout/tagout, mechanical load retention, and verification of residual energy removal. A motor drive’s emergency stop command is not automatically equivalent to safe isolation.

Lifecycle and sustainability

Evaluation should include purchase cost, installation, energy, maintenance, consumables, downtime, disposal, and environmental impact. Efficient electric drives may reduce operating cost, while pneumatic systems may remain preferable when rapid simple motion and inherent compliance outweigh energy cost. Lifecycle analysis should use realistic duty cycles rather than nominal peak ratings.

11. Illustrative Case: Automated Packaging Axis

Background

A packaging machine moves a 12 kg carriage horizontally over 0.50 m. It must complete the move in 0.80 s using a trapezoidal velocity profile: 0.20 s acceleration, 0.40 s constant speed, and 0.20 s deceleration. A belt transmission has efficiency 0.85 and a 40 mm effective pulley diameter. The estimated constant resistance is 25 N.

Problem analysis

For a symmetric triangular acceleration and deceleration pattern, the constant-speed distance is found after selecting a peak speed. Let acceleration magnitude be a and peak speed be vp = a(0.20). The distance during acceleration and deceleration is each ½a(0.20)², while the constant-speed distance is vp(0.40). Thus total distance is

s = a(0.20)² + a(0.20)(0.40) = 0.12a

Setting s = 0.50 m gives a = 4.17 m/s² and vp = 0.833 m/s.

The translational acceleration force is

Fa = ma = 12×4.17 = 50.0 N

During acceleration, total belt force is approximately F = 50.0 + 25 = 75.0 N. The pulley radius is 0.020 m, so the load-side pulley torque is Tp = Fr = 1.50 N·m. With belt efficiency 0.85, motor torque is approximately

Tm = 1.50/0.85 = 1.76 N·m

The pulley angular speed at peak linear velocity is

ω = vp/r = 0.833/0.020 = 41.7 rad/s

or approximately 398 rpm. Acceleration power at peak speed is approximately P = Fv = 75×0.833 = 62.5 W on the load side, before accounting for transmission and motor losses.

Approach and solution

A suitable motor must exceed 1.76 N·m peak torque at approximately 400 rpm and satisfy the repeated-duty thermal requirement. A servo motor with encoder feedback is appropriate if accurate stopping and disturbance rejection are required. A stepper motor could be considered for a low-cost axis, but the acceleration torque margin and risk of missed steps would need testing. The drive should provide current limiting, controlled deceleration, position feedback, overtravel protection, and a safe torque-off function where required.

Outcome and learning points

The example demonstrates that the required motor torque depends on acceleration, resistance, transmission radius, and efficiency. It also shows why speed and torque must be evaluated together: a motor may meet torque at low speed but lack the power or voltage margin at high speed. Final selection would require manufacturer curves, duty-cycle thermal data, belt tension limits, positioning accuracy, emergency stopping distance, and machine risk assessment.

12. Contemporary Developments and Professional Practice

Modern actuator systems increasingly integrate sensors, drives, and communication. Smart servo drives estimate load torque, detect bearing or insulation abnormalities, and report energy use. Digital twins and model-based design can predict thermal loading, resonance, and regenerative energy before hardware is built. Artificial intelligence can assist anomaly detection and predictive maintenance, but it should not replace deterministic safety functions without appropriate validation.

Wide-bandgap semiconductor devices based on silicon carbide or gallium nitride can reduce switching losses and increase switching frequency, enabling smaller filters and higher power density. Integrated motor-drive units reduce wiring and cabinet space but may increase repair complexity and thermal concentration. Electromechanical alternatives to hydraulics are expanding in mobile machinery, although force density, shock loading, and environmental sealing remain important challenges.

Professional engineering decisions should be traceable. Requirements, assumptions, calculations, test results, component ratings, software revisions, and safety decisions should be documented. Actuator systems should be validated under worst-case load, voltage, temperature, friction, and fault conditions rather than only under nominal laboratory conditions.

Chapter Summary

Actuators convert supplied energy into controlled physical action and must be selected as parts of complete mechatronic subsystems. Electric actuators provide precise and efficient control; pneumatics provide fast, compliant, simple motion; hydraulics provide very high force and power density; thermal actuators provide compact but generally slow motion; and smart materials offer specialized high-resolution or adaptive behavior.

Motor sizing requires simultaneous consideration of torque, speed, acceleration, inertia, transmission ratio, efficiency, peak current, continuous heating, duty cycle, regeneration, and environmental limits. Drives and power electronics regulate energy flow using converters, inverters, sensors, switching devices, and protection systems. Transmissions alter speed and torque but introduce efficiency loss, backlash, compliance, and resonance. Safe design must control stored energy and include appropriate isolation, guarding, protection, and validation. The best actuator is the one that satisfies performance, safety, lifecycle, environmental, and maintainability requirements as a balanced system.

Key Terms

Actuator: A device that converts energy into controlled physical motion or another physical output.

Back electromotive force: Voltage generated by a motor that opposes the applied voltage.

Duty cycle: The timing pattern of load, motion, rest, and repetition in operation.

Efficiency: Ratio of useful output power to input power.

Field-oriented control: Control method that resolves AC-machine currents into flux-producing and torque-producing components.

Gear ratio: Ratio relating input and output speed or displacement in a transmission.

Hydraulic actuator: Actuator powered by pressurized liquid.

Inverter: Power converter that produces controlled AC from a DC source.

Moment of inertia: Measure of resistance to angular acceleration.

Pneumatic actuator: Actuator powered by compressed gas, usually air.

PWM: Pulse-width modulation used to control average voltage or power through switching.

Regeneration: Energy flow from a decelerating mechanical system back into an electrical or storage system.

Servo drive: Closed-loop drive that controls motion variables such as torque, speed, or position.

Smart material: Material whose mechanical behavior changes predictably with an applied field or stimulus.

Thermal actuator: Actuator that uses heating, cooling, expansion, or phase change to create motion.

Torque constant: Proportionality constant relating motor current to electromagnetic torque in a simplified model.

Transmission: Mechanical mechanism that transfers and transforms motion and power.

Variable-frequency drive: Drive that controls AC-motor speed by varying electrical frequency and voltage.

Review Questions

5 Short Answer Questions

  1. Why must actuator selection be treated as a system-level decision?
  2. State the relationship between rotational mechanical power, torque, and angular velocity.
  3. Give two advantages and two limitations of pneumatic actuators.
  4. What is the purpose of a braking resistor in a motor drive?
  5. Why can a motor with adequate peak torque still be unsuitable for an application?

5 Long Answer Questions

  1. Compare electric, pneumatic, hydraulic, thermal, and smart-material actuators for an industrial automation application.
  2. Explain the main components and functions of a variable-frequency motor drive.
  3. Derive the approximate motor torque requirement for a geared rotary load and explain the assumptions used.
  4. Discuss how duty cycle, cooling, regenerative braking, and ambient temperature influence motor selection.
  5. Explain how backlash, compliance, and resonance in a transmission affect motion-control performance.

3 Analytical / Application Questions

  1. A vertical axis must lift a 20 kg load at 0.25 m/s. Explain how you would determine motor torque, speed, power, gearbox ratio, braking requirements, and safety provisions.
  2. A factory is considering replacing a hydraulic actuator with an electric servo axis. Develop a decision framework covering force density, energy use, contamination, control accuracy, lifecycle cost, and fail-safe behavior.
  3. Design an initial actuator subsystem for a high-speed pick-and-place mechanism. Justify the actuator type, transmission, drive, feedback, protection, and validation tests using quantitative requirements of your choice.

Multiple Choice Questions with Answers

Question 1

Which equation gives rotational mechanical power?

A. P = Tω

B. P = T/ω

C. P = Jα

D. P = p/A

Correct Answer: A. P = Tω

Question 2

A load inertia is 0.18 kg·m² and angular acceleration is 10 rad/s². What acceleration torque is required, neglecting other torques?

A. 0.018 N·m

B. 0.18 N·m

C. 1.8 N·m

D. 18 N·m

Correct Answer: C. 1.8 N·m

Question 3

Which actuator technology generally provides the highest force density for heavy industrial machinery?

A. Piezoelectric

B. Hydraulic

C. Thermal bimetallic

D. Small stepper motor

Correct Answer: B. Hydraulic

Question 4

For a pneumatic piston, ideal extension force is primarily determined by which relationship?

A. F = pA

B. F = mv

C. F = Jω

D. F = V/I

Correct Answer: A. F = pA

Question 5

What is the main function of an inverter in an AC motor drive?

A. To convert mechanical energy directly into heat

B. To produce controlled AC from a DC link

C. To remove all motor feedback

D. To increase gearbox backlash

Correct Answer: B. To produce controlled AC from a DC link

Question 6

A gearbox has ratio 5 and efficiency 0.8. If load torque is 20 N·m, what motor torque is approximately required for steady operation?

A. 0.625 N·m

B. 4 N·m

C. 5 N·m

D. 125 N·m

Correct Answer: C. 5 N·m

Question 7

Why is motor RMS torque useful in duty-cycle analysis?

A. Copper heating is approximately related to current squared, and current is related to torque

B. It always equals peak torque

C. It ignores all thermal effects

D. It determines gearbox backlash

Correct Answer: A. Copper heating is approximately related to current squared, and current is related to torque

Question 8

What can happen when a motor decelerates and regenerated energy has no available absorption path?

A. The DC-link voltage can rise excessively

B. The motor becomes frictionless

C. The load inertia becomes zero

D. The supply frequency automatically becomes zero

Correct Answer: A. The DC-link voltage can rise excessively

Question 9

Which is a significant limitation of pneumatic positioning compared with many electric servo systems?

A. Compressed air cannot produce force

B. Air compressibility reduces positional stiffness

C. Pneumatic systems require permanent magnets

D. Pneumatic cylinders cannot move linearly

Correct Answer: B. Air compressibility reduces positional stiffness

Question 10

For a thermal expansion calculation, what does α represent in ∆L = αL0∆T?

A. Angular acceleration

B. Electrical resistivity

C. Coefficient of thermal expansion

D. Hydraulic pressure

Correct Answer: C. Coefficient of thermal expansion