Hydraulic Pumps, Power Units and AccumulatorsIntroduction and ContextA hydraulic system converts mechanical energy into controlled fluid power. The pump is the primary energy-conversion device: it receives mechanical torque from an electric motor, internal-combustion engine, or other prime mover and produces a flow of pressurized hydraulic fluid. Pressure is not created by the pump alone; pressure develops when flow encounters resistance in actuators, valves, piping, and the load. This distinction is fundamental to safe analysis and design. A complete hydraulic power unit (HPU) normally includes a pump, prime mover, reservoir, filtration, pressure-control devices, heat-management equipment, instrumentation, and connecting hardware. An accumulator may be added to store energy, absorb shock, compensate for leakage, or supply short-duration peak flow. The engineer must select a pump not only by nominal flow and pressure, but also by displacement, speed range, efficiency, noise, contamination tolerance, control method, duty cycle, cost, and maintainability. Learning ObjectivesAfter completing this chapter, the student should be able to: - Explain the operating principles and applications of gear, vane, fixed-piston, and variable-displacement pumps.
- Calculate theoretical displacement, flow rate, torque, hydraulic power, and efficiency.
- Distinguish volumetric, mechanical, and overall efficiency.
- Design the principal elements of a hydraulic power unit.
- Explain accumulator construction, pre-charge, sizing, and safety requirements.
- Select pressure-control devices and identify common causes of pump and power-unit failure.
- Evaluate a practical hydraulic-power application using engineering assumptions and constraints.
1. Hydraulic Pump Fundamentals1.1 Positive-displacement operationMost industrial hydraulic pumps are positive-displacement machines. Each shaft revolution traps a nearly defined volume of fluid and transports it from inlet to outlet. The ideal flow is therefore proportional to displacement and rotational speed. Qt = Vd n Here, Qt is theoretical flow (m³/s), Vd is displacement per revolution (m³/rev), and n is rotational speed (rev/s). If speed is given in revolutions per minute, n = N/60, where N is in r/min. Actual flow differs from theoretical flow because of internal leakage, fluid compressibility, aeration, and filling limitations. Volumetric efficiency is ηv = Qa / Qt where Qa is actual delivery flow. Thus, Qa = ηv Vd n This relation applies to a positive-displacement pump operating within its specified speed, pressure, viscosity, and inlet conditions. The pump produces flow; the system resistance determines operating pressure. A relief valve, load-sensing control, or other pressure-control device establishes the pressure limit or operating condition. 1.2 Displacement and flow conversionsA useful engineering conversion is: Q(L/min) = Vd(cm³/rev) × N(r/min) × ηv / 1000 The factor 1000 arises because 1 L = 1000 cm³. For a non-leaking theoretical calculation, set ηv = 1. For SI calculations, pressure should be expressed in pascals and flow in cubic metres per second. For practical hydraulic calculations, the following equivalent power relation is convenient: Ph(kW) = p(bar) × Q(L/min) / 600 where p is pressure in bar and Q is actual flow in L/min. This is hydraulic output power, not motor input power. 1.3 Torque and pressureThe ideal torque required by a positive-displacement pump follows from work per revolution. Pressure multiplied by displacement is energy per revolution: Tt = p Vd / (2π) where Tt is theoretical torque (N·m), p is pressure difference across the pump (Pa), and Vd is displacement per revolution (m³/rev). Actual shaft torque is greater because of mechanical losses: Ts = p Vd / (2π ηm) where ηm is mechanical efficiency. This expression assumes pressure is the pump differential pressure, rather than an absolute pressure reading. Shaft power is Ps = 2π n Ts and, using actual flow, ηo = Ph / Ps = ηv ηm where ηo is overall efficiency. The product relationship is a useful engineering model when volumetric and mechanical losses are treated separately. Worked Example 1: Pump flow, power, and torqueA pump has a displacement of 25 cm³/rev and rotates at 1,500 r/min. Its volumetric efficiency is 0.92, mechanical efficiency is 0.88, and it operates at 140 bar differential pressure. Determine actual flow, hydraulic power, shaft torque, and shaft power. The actual flow is Q = 25 × 1500 × 0.92 / 1000 = 34.5 L/min Hydraulic power is Ph = 140 × 34.5 / 600 = 8.05 kW Theoretical torque is Tt = (14,000,000 × 25 × 10⁻⁶)/(2π) = 55.7 N·m The shaft torque is Ts = 55.7/0.88 = 63.3 N·m Shaft power is Ps = 2π(1500/60)(63.3) = 9.94 kW The overall efficiency is 8.05/9.94 = 0.81, also equal to 0.92 × 0.88 = 0.8096. A motor rated only at 8 kW would be unsuitable because it would not provide an adequate allowance for losses, starting, temperature, and service duty. 2. Principal Pump Types2.1 External and internal gear pumpsAn external gear pump uses two meshing gears. The gears carry fluid around the outer casing from the inlet to the outlet; fluid does not normally pass through the meshing region because the teeth and pressure plates form a sealing boundary. One gear is driven and the other is driven through the mesh. Advantages include simple construction, low cost, compactness, good contamination tolerance relative to close-clearance designs, and reliable operation. Limitations include fixed displacement in common designs, pulsation, gear-mesh noise, and decreasing efficiency at high pressure or low viscosity. Internal gear pumps use an internal gear and a smaller pinion, often with a crescent-shaped separator. They can operate quietly and provide relatively smooth flow. Gerotor pumps are a related form in which an inner rotor and outer rotor create fluid chambers. Gear pumps are common in mobile machinery, lubrication systems, machine tools, and auxiliary circuits. They are often appropriate where constant flow and moderate pressure are required. 2.2 Vane pumpsA vane pump contains a rotor mounted eccentrically within a cam ring. Sliding vanes move radially in rotor slots and maintain contact with the cam ring. As the chamber volume increases, fluid enters; as it decreases, fluid is discharged. Balanced vane pumps use opposed inlet and outlet regions to reduce radial bearing loads. Vane pumps generally provide lower noise and smoother flow than many gear pumps. They offer good efficiency at moderate pressures and are widely used in industrial power units. They require suitable fluid cleanliness and viscosity because vane-tip contact and close clearances are sensitive to contamination and wear. Fixed-displacement vane pumps are simple, whereas pressure-compensated variable-displacement vane pumps can reduce flow when system demand falls. A variable vane pump is particularly useful in systems with extended idle periods, because it can reduce throttling losses and heat generation. 2.3 Axial-piston pumpsIn an axial-piston pump, several pistons move parallel to the drive shaft. A swash plate or bent-axis mechanism converts rotary motion into reciprocating piston motion. Each piston draws in and discharges fluid through port plates or valve arrangements. Axial-piston pumps can operate at high pressure and provide high power density. They may be fixed or variable displacement. Their disadvantages include higher cost, tighter contamination requirements, more complex controls, and potentially greater sensitivity to incorrect installation or inadequate lubrication. In a swash-plate pump, displacement is related to piston area, number of pistons, and stroke. A simplified model for a pump with z pistons, piston area Ap, and stroke L is: Vd ≈ z Ap L This is a geometric approximation. Actual manufacturer displacement depends on the detailed porting and piston arrangement; the rating supplied by the manufacturer must be used for final design. 2.4 Variable-displacement pumpsA variable-displacement pump changes Vd while the shaft speed may remain nearly constant. The most important control modes are: - Pressure compensation: reduces displacement when outlet pressure reaches a set value.
- Load sensing: adjusts displacement so that pump pressure remains a controlled margin above the highest actuator load pressure.
- Power limiting: reduces displacement as pressure increases so that shaft power remains within a specified limit.
- Proportional or electronic control: uses electrical commands and feedback to regulate displacement.
A variable pump can substantially reduce energy loss in systems with changing demand. However, control instability, incorrect compensator adjustment, inadequate signal lines, and contamination can impair performance. Pump comparison| Pump type | Main strengths | Typical limitations | Common applications |
|---|
| External gear | Simple, economical, robust | Fixed displacement, noise, moderate pressure | Mobile auxiliaries, lubrication | | Internal gear | Quiet, smooth, reliable | Costlier than external gear | Industrial power units | | Vane | Low noise, smooth flow | Clean-fluid requirement, moderate pressure | Machine tools, industrial systems | | Fixed axial piston | High pressure and power density | Cost and contamination sensitivity | High-pressure circuits | | Variable axial piston | Efficient under changing demand | Complex and expensive | Injection molding, mobile drives |
3. Pump Selection and Operating LimitsPump selection must begin with the required actuator speed, force or torque, pressure, duty cycle, and control response. The pump must also be checked against: - maximum and continuous pressure;
- minimum and maximum shaft speed;
- inlet pressure and suction-line velocity;
- fluid viscosity and temperature;
- permitted contamination level;
- noise and vibration limits;
- shaft, coupling, and mounting requirements;
- serviceability and spare-parts availability.
A pump rated for a short peak pressure should not be operated continuously at that pressure. Similarly, nominal displacement does not guarantee rated flow: actual output depends on pressure, speed, viscosity, and wear. Inlet conditions and cavitationCavitation occurs when local fluid pressure falls below the fluid vapor pressure, producing vapor bubbles that collapse in higher-pressure regions. Symptoms include crackling noise, vibration, erratic flow, surface pitting, and rapid failure. Causes include a restricted suction filter, undersized inlet line, excessive fluid temperature, low reservoir level, high speed, or excessively viscous fluid. The pump inlet must maintain an adequate absolute pressure margin. The available net positive suction head may be expressed conceptually as: NPSHa = pabs,inlet/(ρg) − pv/(ρg) + v²/(2g) where pabs,inlet is absolute inlet pressure, pv is vapor pressure, ρ is fluid density, g is gravitational acceleration, and v is inlet velocity. The precise acceptance criterion is manufacturer-specific; NPSHa must exceed the pump’s required inlet margin with an appropriate safety allowance. Never diagnose cavitation solely by increasing pressure-compensator settings. The inlet circuit must be inspected first. 4. Hydraulic Power-Unit Design4.1 Functional architectureA typical HPU consists of the following flow path: Reservoir → suction strainer or clean inlet → pump → check valve and pressure-control manifold → directional and flow-control valves → actuators → return filtration and cooler → reservoir. The reservoir performs several functions: it stores sufficient fluid, permits heat dissipation, allows entrained air to separate, provides a location for contamination settlement, and accommodates thermal expansion. It must be baffled so that returning fluid does not immediately travel to the pump inlet. A common preliminary reservoir estimate for industrial circuits is a volume of approximately two to four times the pump delivery per minute, but this is a design guideline rather than a universal rule. Actual sizing depends on duty cycle, heat rejection, air release, machine geometry, and manufacturer requirements. 4.2 Prime mover and couplingThe motor must supply the required shaft power continuously and tolerate peak loading. A practical selection includes a service margin for efficiency changes, acceleration, cold-fluid viscosity, and transient loads. Direct couplings must be aligned accurately; flexible couplings do not compensate for gross misalignment. The pump shaft must not carry external radial or axial loads unless specifically designed for them. 4.3 Pressure-control devicesThe principal pressure-control devices are: - Relief valve: limits maximum system pressure by diverting flow to the reservoir.
- Pressure-reducing valve: maintains lower pressure in a branch circuit.
- Sequence valve: permits one operation after a preset pressure is reached.
- Counterbalance valve: controls overrunning loads and prevents uncontrolled actuator motion.
- Unloading valve: diverts pump flow at low pressure when the circuit is idle or an accumulator is charged.
- Pressure-compensator control: changes pump displacement in response to pressure.
A relief valve is a safety and limiting device, not a substitute for correct pump sizing. Continuous flow across a relief valve converts input power into heat. For example, the heat generated by bypassing Q through a valve at pressure p is approximately Ploss = pQ with pressure in Pa and flow in m³/s. In practical units, Ploss(kW) = p(bar)Q(L/min)/600. 4.4 Filtration, cooling, and instrumentationFilters should be selected by cleanliness target, flow capacity, pressure drop, collapse strength, and bypass-valve behavior. A return filter protects the reservoir and pump, while a pressure-line filter protects sensitive valves and actuators. Excessively fine filtration can cause unacceptable pressure drop if the element is undersized. Temperature must remain within the fluid and seal manufacturer’s limits. Heat input comes from pump and motor losses, throttling, leakage, and relief-valve operation. Heat rejection occurs through the reservoir, piping, and cooler. Pressure gauges should be installed at diagnostically useful points, and pressure switches or transducers may provide control and condition monitoring. 4.5 Cleanliness and fluid compatibilityWater contamination, particles, air, and incorrect viscosity are major causes of hydraulic failure. Good practice includes filtered filling, sealed containers, clean hoses, capped open ports, correct filter replacement, and documented cleanliness inspections. Fluid, seal, hose, paint, and electrical-component compatibility must be verified before commissioning. 5. Accumulators5.1 Purpose and constructionAn accumulator stores hydraulic energy by compressing a gas, usually nitrogen. Common types are bladder, piston, and diaphragm accumulators. Oxygen or compressed air must not be used where it could create a fire or explosion hazard with hydraulic oil. Applications include: - supplying short-duration peak flow;
- absorbing pressure pulsations and shocks;
- compensating for leakage;
- maintaining pressure during brief power loss;
- dampening pump ripple;
- storing energy for emergency movement;
- reducing pump cycling.
A gas-charged accumulator is a pressure vessel and must be selected, installed, inspected, and tested according to applicable pressure-equipment regulations and manufacturer instructions. 5.2 Gas-law modelFor a sufficiently rapid process with limited heat transfer, the gas may be approximated as polytropic: p Vk = constant where p is absolute gas pressure, V is gas volume, and k is the polytropic exponent. For approximately isothermal operation, k ≈ 1; for rapid adiabatic behavior in nitrogen, k is commonly approximated near 1.4. Actual accumulator performance lies between these idealizations and depends on cycle time, heat transfer, and gas condition. Between two states: p1 V1k = p2 V2k Pressures in this gas-law equation must be absolute. Gauge pressure must be converted using pabs = pgauge + patmospheric. If the gas is pre-charged to pressure p0 at gas volume V0, and the hydraulic pressure changes from p1 to p2, the usable fluid volume is ∆V = V0[(p0/p2)^(1/k) − (p0/p1)^(1/k)] provided p0 < p1 < p2, with all pressures absolute and the accumulator operating within its mechanical limits. This formula represents gas expansion from the higher hydraulic pressure state to the lower hydraulic pressure state. Worked Example 2: Accumulator usable volumeA bladder accumulator has a nominal gas volume of 10 L. It is pre-charged to 70 bar gauge. It must supply fluid as system pressure falls from 140 bar gauge to 100 bar gauge. Assume an isothermal process. Atmospheric pressure is 1 bar. Convert to absolute pressure: p0 = 71 bar, p1 = 141 bar, and p2 = 101 bar. With k = 1, ∆V = 10[(71/101) − (71/141)] = 2.11 L Thus, the ideal usable volume is approximately 2.11 L. Real delivered volume may be lower because of bladder limits, valve geometry, temperature effects, gas dissolution, and required safety margins. The pre-charge must be checked at the specified gas temperature and with the hydraulic side safely depressurized. 5.3 Accumulator installation and safetyAn accumulator should normally have an isolation valve, pressure-relief protection, a safe means of depressurization, and a clearly identified gas-charging connection. A suitable block may include a gauge, shutoff valve, bleed valve, and relief device. The accumulator must be mounted securely and protected from impact and excessive temperature. Incorrect pre-charge can cause poor performance. Excessive pre-charge may cause bladder damage, loss of fluid delivery, and unstable operation; insufficient pre-charge reduces stored energy and may permit bladder collapse or piston impact. Maintenance records should identify pre-charge pressure, inspection date, fluid compatibility, and regulatory test status. 6. Worked Design Example: Clamping Power UnitBackgroundConsider an illustrative machine-tool clamping circuit requiring a cylinder flow of 30 L/min at a maximum working pressure of 120 bar. The clamp operates intermittently, with periods of holding pressure and low-flow standby. The design objective is to provide reliable clamping while limiting heat generation. AnalysisA fixed-displacement pump delivering 30 L/min continuously would send much of its flow across a relief or unloading path during the holding period. At 120 bar, continuous bypass power would be P = 120 × 30 / 600 = 6.0 kW before considering efficiency. This is undesirable if the clamp spends significant time at pressure. Approach and solutionA suitable preliminary design uses a variable-displacement pressure-compensated pump rated above 120 bar, with a maximum displacement selected to provide at least 30 L/min at the intended motor speed. A relief valve is set above the normal compensator setting but below the safe rating of the weakest component. A pressure-reducing or clamp-control valve may be used if the cylinder requires a pressure lower than the main circuit. The reservoir must provide adequate deaeration and heat rejection. Return filtration, a suction arrangement with low pressure loss, and a pressure gauge near the clamp valve are specified. If rapid clamping is needed but the pump motor is limited, an accumulator may provide peak flow while the pump recharges it during the non-clamping interval. A check valve prevents reverse flow through the pump. For example, if the accumulator supplies 12 L during rapid clamping and the required flow is 30 L/min, its ideal support time is t = ∆V/Q = 12/30 = 0.4 min = 24 s assuming both quantities use litres and minutes. The accumulator must then be sized using the gas-law relation, not merely by equating nominal volume to delivered volume. OutcomeThe variable pump reduces standby losses, while the relief valve provides overpressure protection. Instrumentation permits verification of pump pressure, clamp pressure, filter condition, and accumulator pre-charge. The final design would require detailed thermal analysis, component ratings, risk assessment, and validation testing. Learning points- The required actuator flow determines pump delivery, but the duty cycle determines the appropriate control strategy.
- A relief valve set point does not by itself make every component safe.
- Accumulator nominal volume is not equal to usable fluid volume.
- Energy efficiency depends on avoiding unnecessary throttling and bypass flow.
- Commissioning measurements are essential because actual efficiencies and leakage differ from catalog values.
7. Troubleshooting, Limitations, and Professional PracticeCommon symptoms should be interpreted systematically: | Symptom | Likely causes | Initial checks |
|---|
| Low flow | Worn pump, low speed, inlet restriction, low volumetric efficiency | Measure speed, pressure, temperature, and flow | | Excessive noise | Cavitation, aeration, misalignment, mechanical wear | Inspect suction line, fluid level, coupling | | Overheating | Relief bypass, excessive leakage, undersized cooler | Measure pressure, flow, temperature, and bypass time | | Pressure instability | Air, compensator fault, contaminated valve, incorrect pre-charge | Bleed air, inspect controls, test accumulator | | Slow actuator | Insufficient pump flow, leakage, restrictive valve | Test flow at pump and actuator | | Premature failure | Contamination, wrong viscosity, overload, poor installation | Review maintenance and operating records |
The principal limitations of simplified calculations are that efficiencies vary with pressure and speed, fluid properties vary with temperature, and transient behavior can be important. Manufacturer performance curves and system tests must replace preliminary equations during final selection. Professional practice requires guarding rotating couplings, preventing unexpected actuator motion, locking out electrical and hydraulic energy, and discharging accumulators before maintenance. Hydraulic injection injuries can occur through apparently small leaks and require urgent medical treatment. Designers must comply with applicable machinery, pressure-vessel, electrical, environmental, and occupational-safety regulations. Contemporary systems increasingly use electronic displacement controls, pressure and temperature sensors, digital condition monitoring, and networked diagnostics. Data analytics or AI may identify trends in temperature, pressure ripple, filter differential pressure, and efficiency, but sensor validation, cybersecurity, explainability, and human authorization remain necessary. Automated diagnosis must never override a physical safety relief function or a safe isolation procedure. Best-Practice Design Checklist- Define required pressure, flow, speed, duty cycle, and environmental conditions.
- Select pump displacement from actual flow requirements and expected volumetric efficiency.
- Check shaft torque and motor power using differential pressure.
- Protect the system with correctly rated relief and isolation devices.
- Minimize suction losses and verify inlet pressure against cavitation risk.
- Size the reservoir, filters, cooler, and piping for the actual duty cycle.
- Use compatible, clean fluid and document contamination-control procedures.
- Size accumulators with absolute pressures and an appropriate gas-law model.
- Provide safe accumulator isolation, depressurization, and inspection facilities.
- Commission the HPU by measuring pressure, flow, temperature, speed, noise, and leakage.
Chapter SummaryHydraulic pumps convert mechanical input into fluid flow, while system resistance and control devices determine pressure. Positive-displacement pump flow is based on displacement and speed, corrected by volumetric efficiency. Differential pressure and displacement determine theoretical torque; mechanical efficiency determines actual shaft torque. Hydraulic power equals pressure multiplied by actual flow, and overall efficiency is approximately the product of volumetric and mechanical efficiencies. Gear pumps are simple and robust, vane pumps provide smooth and quiet operation, and piston pumps provide high pressure and power density. Variable-displacement pumps improve efficiency when demand changes, but require careful control and contamination management. A hydraulic power unit integrates the pump, prime mover, reservoir, filtration, pressure controls, cooling, instrumentation, and safe piping. Accumulators store energy through gas compression and must be sized using absolute pressure and an appropriate polytropic model. Good design combines calculation, manufacturer data, cleanliness control, thermal analysis, commissioning, and regulatory safety practice. Key TermsPositive-displacement pump: A pump that transports a defined volume of fluid per shaft revolution. Displacement: The theoretical fluid volume moved per revolution. Volumetric efficiency: Actual pump flow divided by theoretical flow. Mechanical efficiency: Theoretical pump torque divided by actual shaft torque. Overall efficiency: Hydraulic output power divided by shaft input power. Gear pump: A pump that transports fluid using meshing gears. Vane pump: A pump using sliding vanes and a cam ring to vary chamber volume. Axial-piston pump: A pump whose pistons move parallel to the drive shaft. Variable displacement: A pump characteristic allowing displacement to be changed during operation. Pressure compensator: A control that reduces pump displacement at a selected pressure. Load sensing: A control method that adjusts pump pressure and flow in relation to load demand. Cavitation: Vapor-bubble formation and collapse caused by inadequate local absolute pressure. Reservoir: A tank that stores, cools, and deaerates hydraulic fluid. Relief valve: A valve that limits maximum pressure by diverting flow. Accumulator: A pressure vessel that stores hydraulic energy using compressed gas. Pre-charge: Initial gas pressure in an accumulator before hydraulic fluid is admitted. Polytropic process: A gas process represented by pVk = constant. Hydraulic power unit: An integrated assembly supplying controlled hydraulic power. NPSH: Net positive suction head, a measure of inlet pressure margin against vaporization. Pressure differential: The pressure difference between pump outlet and inlet. Review Questions5 Short Answer Questions- Why does pressure develop in a hydraulic system even though the pump primarily produces flow?
- Define volumetric efficiency and state how it affects pump delivery.
- State two advantages and two limitations of axial-piston pumps.
- What functions does a hydraulic reservoir perform?
- Why must accumulator gas-law calculations use absolute pressure?
5 Long Answer Questions- Explain the construction, operation, advantages, limitations, and applications of gear, vane, and piston pumps.
- Derive the relationship between pump differential pressure, displacement, and theoretical shaft torque.
- Describe the major components of a hydraulic power unit and explain how they interact during normal operation.
- Explain cavitation, its causes, symptoms, consequences, and prevention methods.
- Compare fixed-displacement and variable-displacement pump systems from energy, control, cost, and maintenance perspectives.
3 Analytical / Application Questions- A pump has a displacement of 32 cm³/rev, operates at 1,200 r/min, and has volumetric efficiency 0.90. Calculate its actual flow in L/min. If it operates at 160 bar, calculate hydraulic power.
- A machine requires 25 L/min for 15 s during each cycle, while the pump can provide only 15 L/min. Determine the missing fluid volume and explain what additional accumulator information is needed before selecting its nominal gas volume.
- A power unit overheats while maintaining a load. Develop a diagnostic sequence involving pressure, flow, temperature, relief-valve operation, pump efficiency, filtration, and reservoir cooling.
Multiple Choice Questions with AnswersQuestion 1A positive-displacement pump has a displacement of 20 cm³/rev, speed of 1,500 r/min, and volumetric efficiency of 0.90. What is its actual flow? A. 27 L/min B. 30 L/min C. 33.3 L/min D. 36 L/min Correct Answer: A. 27 L/min Question 2Which statement most accurately describes a hydraulic pump? A. It creates pressure independently of system resistance. B. It produces fluid flow, while resistance produces pressure. C. It converts hydraulic power directly into mechanical torque. D. It prevents all leakage in a hydraulic circuit. Correct Answer: B. It produces fluid flow, while resistance produces pressure. Question 3A pump operates at 100 bar and delivers 24 L/min. Its hydraulic output power is approximately: A. 2.4 kW B. 4.0 kW C. 6.0 kW D. 14.4 kW Correct Answer: B. 4.0 kW Question 4Which pump type is generally most associated with high pressure and high power density? A. External gear pump B. Fixed vane pump C. Axial-piston pump D. Centrifugal fan pump Correct Answer: C. Axial-piston pump Question 5What is the principal purpose of a hydraulic relief valve? A. To increase pump displacement B. To remove dissolved air from fluid C. To limit maximum system pressure D. To measure reservoir temperature Correct Answer: C. To limit maximum system pressure Question 6Which condition most directly increases the risk of pump cavitation? A. A large, unrestricted suction line B. A low fluid temperature within specification C. A restricted suction filter D. A properly baffled reservoir Correct Answer: C. A restricted suction filter Question 7A pump has theoretical torque of 50 N·m and mechanical efficiency of 0.80. Its approximate actual shaft torque is: A. 40 N·m B. 50 N·m C. 62.5 N·m D. 80 N·m Correct Answer: C. 62.5 N·m Question 8What gas is normally specified for charging a hydraulic accumulator? A. Oxygen B. Nitrogen C. Hydrogen D. Compressed natural gas Correct Answer: B. Nitrogen Question 9In an accumulator gas-law calculation, which pressure must be used? A. Gauge pressure only B. Vacuum pressure only C. Absolute pressure D. Pressure drop across the return filter Correct Answer: C. Absolute pressure Question 10Which control strategy adjusts pump displacement so pressure remains a controlled margin above load pressure? A. Load sensing B. Manual throttling only C. Reservoir baffling D. Return filtration Correct Answer: A. Load sensing
|