Hydraulics and Pneumatics

Chapter 5
Hydraulic Actuators and Control Valves

Bachelors Program in Machine Technology
Hydraulics and Pneumatics   •   Bachelor

Hydraulic Actuators and Control Valves

Introduction and Context

Hydraulic actuators convert fluid power into controlled linear or rotary motion. Control valves regulate the direction, pressure, flow rate, and logic of hydraulic energy. Together, actuators and valves form the functional core of hydraulic machinery used in presses, machine tools, injection-moulding machines, mobile equipment, lifting systems, and automated production lines.

A sound design does more than select a cylinder or valve from a catalogue. The designer must determine force, speed, torque, power, pressure, flow, duty cycle, stability, controllability, efficiency, safety, and compatibility with the hydraulic power unit. Incorrect sizing can cause excessive energy consumption, overheating, slow operation, instability, seal failure, or dangerous uncontrolled movement.

This chapter develops the operating principles and selection methods for hydraulic cylinders, rotary actuators, hydraulic motors, and the principal valve families: directional, pressure-control, flow-control, check, cartridge, and logic valves.

Learning Objectives

By the end of this chapter, the reader should be able to:

  • distinguish among linear actuators, rotary actuators, and hydraulic motors;
  • calculate cylinder force, speed, flow requirement, and hydraulic power;
  • select cylinders using load, stroke, buckling, mounting, and duty considerations;
  • explain the construction and operation of vane, piston, and gear-type motors;
  • identify the functions and symbols of directional, pressure, flow, check, cartridge, and logic valves;
  • select valves using pressure, flow, response, leakage, and control requirements;
  • analyse a hydraulic actuator circuit and identify likely design limitations;
  • apply safe and efficient design practices to an industrial system.

1. Hydraulic Actuators: Energy Conversion

Hydraulic power is transmitted by pressurised fluid. An actuator receives flow Q at pressure p and produces mechanical output. The ideal hydraulic power is

Ph = pQ

where Ph is hydraulic power in watts, p is pressure in pascals, and Q is volumetric flow rate in cubic metres per second. In practical calculations, if pressure is in MPa and flow is in L/min,

Ph\,[kW] = \frac{p\,[MPa] × Q\,[L/min]}{60}

This relationship assumes consistent units and represents input fluid power, not useful mechanical output. Actual output is lower because of volumetric, mechanical, and hydraulic losses.

Actuators are classified as:

ActuatorOutput motionTypical use
Hydraulic cylinderReciprocating linear motionPresses, clamps, lifting and feeding
Rotary actuatorLimited-angle rotationIndexing, positioning, clamping
Hydraulic motorContinuous rotary motionConveyors, winches, wheels and tools

A complete actuator selection requires the load profile, required motion, available pressure and flow, mounting arrangement, environmental conditions, control accuracy, and safety requirements.

2. Hydraulic Cylinders

2.1 Construction

A typical double-acting cylinder consists of a barrel, piston, piston rod, piston seals, rod seal, wiper, guide or bearing, end caps, and fluid ports. The piston divides the barrel into cap-end and rod-end chambers. Pressurising either chamber produces motion in the corresponding direction.

Single-acting cylinders are powered hydraulically in one direction and return by a spring, gravity, or an external load. Double-acting cylinders are powered in both directions and are preferred where positive control of extension and retraction is required.

Common cylinder configurations include tie-rod, welded, mill-duty, telescopic, tandem, and differential cylinders. Tie-rod cylinders are convenient for maintenance and moderate industrial duty. Welded cylinders have compact construction and high resistance to external loads, making them common in mobile machinery.

2.2 Force and speed

For a cylinder with bore diameter D, rod diameter d, and pressure p, the cap-end piston area is

Ac = \frac{πD2}{4}

The annular rod-end area is

Ar = \frac{π(D2-d2)}{4}

Ignoring friction and back pressure, extension force and retraction force are respectively

Fext = pcAc - prAr
Fret = prAr - pcAc

Here, pc and pr are the pressures in the cap-end and rod-end chambers. These general equations include chamber back pressure. If the opposing chamber returns freely to tank, its pressure may be approximated as zero, giving Fext ≈ pAc or Fret ≈ pAr. Real force is reduced by seal friction and mechanical losses.

Cylinder velocity follows continuity:

v = \frac{Q}{A}

where v is piston velocity, Q is chamber flow, and A is the effective area. Thus, for equal pump flow, retraction is faster than extension because Ar < Ac. This is called differential or regenerative behaviour only when the circuit deliberately connects the rod-end return flow to the cap end; ordinary retraction is simply faster because the rod-end area is smaller.

Cylinder stroke volume is approximately

V = AL

where L is stroke length. The ideal time for a stroke is

t = \frac{AL}{Q}

Actual time may be longer because of leakage, valve pressure drop, acceleration, deceleration, and pump-flow variation.

Worked Example 1: Cylinder force, speed, and power

A double-acting cylinder has a 100 mm bore and a 60 mm rod. It extends at 10 MPa using 30 L/min. Determine ideal extension force, extension speed, and hydraulic power.

The cap-end area is

Ac = \frac{π(0.100)2}{4} = 0.007854\,m2

Therefore,

Fext = 10×106 × 0.007854 = 78.5\,kN

Convert flow:

Q = \frac{30×10-3}{60} = 0.0005\,m3/s

The ideal extension speed is

v = \frac{0.0005}{0.007854} = 0.0637\,m/s

Hydraulic power is

Ph = \frac{10×30}{60} = 5.0\,kW

These are ideal values. A practical design must allow for friction, pressure losses, and a suitable safety margin. If the required load is close to 78.5 kN, a larger cylinder or higher pressure would be necessary.

2.3 Cylinder selection

Cylinder bore is selected from the required force and allowable working pressure. A preliminary bore can be estimated from

D = \sqrt{\frac{4F}{πpηm}}

where F is required force, p is design pressure, and ηm is an allowance for mechanical efficiency. The equation is a preliminary sizing relation; catalogue selection must then consider standard bore sizes, pressure rating, cushion design, seals, and mounting.

Rod diameter cannot be selected from tensile force alone. A slender rod under compression may buckle. The designer should check Euler or manufacturer-rated buckling limits using the effective length, end conditions, material stiffness, and safety factor. A cylinder should also be guided externally when side loading is significant. The piston rod is not intended to function as a structural guide.

Important selection factors include:

  • Stroke and retracted length: the cylinder must fit the available envelope.
  • Mounting: flange, foot, trunnion, clevis, and spherical mounts accommodate different load paths.
  • Side load: external guides or bearings may be required.
  • Cushioning: adjustable cushions reduce end-of-stroke impact by restricting exhaust flow near the ends.
  • Speed: high speed may require larger ports, suitable seals, and controlled deceleration.
  • Buckling: compression loading and long extension demand a larger rod or guided arrangement.
  • Environment: temperature, dust, water, corrosion, and chemical exposure determine seal and rod materials.
  • Position feedback: magnetostrictive, linear-resolver, or other sensors may be required for closed-loop control.

2.4 Cylinder circuits and regeneration

A four-way directional valve can send pump flow to either chamber and return the opposite chamber to tank. A meter-out flow-control valve regulates exhaust flow and often gives better control of overrunning loads than meter-in control. Counterbalance valves prevent a vertical load from falling when directional control is centred or a hose fails, although they must be adjusted and piloted correctly to avoid excessive pressure and instability.

In a regenerative extension circuit, rod-end flow is redirected to the cap end. The effective driving area becomes approximately the rod area, so extension speed increases but available force decreases. Regeneration is useful for rapid approach, but it is generally unsuitable during the high-force portion of a press stroke unless the circuit changes mode.

3. Rotary Actuators and Hydraulic Motors

3.1 Limited-angle rotary actuators

Rotary actuators convert hydraulic energy into angular motion over a restricted angle, commonly 90°, 180°, or several revolutions. Rack-and-pinion units use a linear piston and rack to rotate a pinion. Vane actuators use pressure acting on one or more vanes. Helical or orbital designs can provide high torque in compact packages.

Torque is approximately

T = pVdηm/(2π)

where T is torque in N·m, Vd is displacement per revolution in m³/rev, p is pressure difference in Pa, and ηm is mechanical efficiency. For a limited-angle actuator, displacement is specified per angular movement rather than necessarily per full revolution.

Angular speed is related to flow by

ω = \frac{2πQηv}{Vd}

where ω is angular speed in rad/s and ηv is volumetric efficiency. These equations apply to positive-displacement rotary devices under approximately steady conditions.

3.2 Hydraulic motors

Hydraulic motors provide continuous rotation. Major types are:

Motor typeStrengthsTypical limitations
GearSimple, economical, tolerant of contaminationModerate efficiency and fixed displacement
VaneSmooth operation, compact designSensitive to contamination and pressure limits
Axial pistonHigh pressure, high efficiency, variable displacementHigher cost and greater cleanliness requirements
Radial pistonVery high torque and low speedLarger and more expensive
Gerotor/orbitalHigh starting torque, compactLimited high-speed and high-pressure combinations

Motor speed is approximately

n = \frac{Qηv}{Vd}

where n is rotational speed in revolutions per second. Torque is approximately

T = \frac{ΔpVdηm}{2π}

where Δp is the pressure difference between inlet and outlet. The ideal power relation is P = ΔpQ, while mechanical output is reduced by total efficiency.

Motor selection must consider continuous and intermittent pressure, speed range, starting torque, braking, direction reversal, case-drain requirements, shock loading, and allowable outlet pressure. A piston motor with an external case drain must never have its drain blocked or subjected to excessive pressure.

Worked Example 2: Motor selection

A motor must deliver 2,000 N·m at a pressure difference of 20 MPa. Assume mechanical efficiency ηm = 0.90. Required displacement is estimated from

Vd = \frac{2πT}{Δpηm}

Thus,

Vd = \frac{2π×2000}{20×106×0.90}
= 0.000698\,m3/rev
= 698\,cm3/rev

A catalogue motor with at least this displacement and suitable continuous pressure rating should be selected. If the motor must operate at 60 rpm and volumetric efficiency is 0.95, required flow is

Q = \frac{nVd}{ηv}

With n = 60\,rev/min,

Q = \frac{60×0.000698}{0.95} = 0.0441\,m3/min = 44.1\,L/min

The pump and valve must therefore supply approximately 44 L/min, before allowing for other circuit flows and pressure losses.

4. Directional-Control Valves

Directional-control valves start, stop, and reverse actuator motion. Their designation normally states the number of ports and positions. A 4/3 valve has four working ports—pressure, tank, actuator port A, and actuator port B—and three spool positions.

Valve centres have different functions:

  • Closed centre: all ports blocked; useful for stopping actuators but may cause pump pressure rise unless an unloading arrangement is provided.
  • Tandem centre: pressure connected to tank while actuator ports are blocked; suitable for fixed-displacement pumps in many circuits.
  • Float centre: actuator ports connected to tank; allows an actuator to move freely under an external force.
  • Open centre: all principal ports interconnected; common in some mobile or multiple-valve systems.

Spool valves provide flexible switching and are available as solenoid, pilot-operated, manually operated, or proportional valves. Poppet valves provide low leakage and high pressure capacity but may require pilot control for large flows. Directional valves must be selected for rated pressure, rated flow, switching time, leakage, spool overlap, and electrical duty.

Proportional and servo valves vary flow or pressure continuously. Proportional valves are appropriate for general motion control; servo valves offer high dynamic response and low hysteresis but demand cleaner fluid, precise electronics, and careful filtration.

Simplified hydraulic cylinder circuit ReservoirTank Pump 4/3 directional valveExtendRetract CylinderA/B ports Pressure flowReturn flow
Simplified hydraulic cylinder circuit with pump, directional valve and tank
Figure: Simplified hydraulic cylinder circuit with pump, directional valve and tank

Figure: Simplified circuit showing a pump, 4/3 directional valve, double-acting cylinder, and return to tank. Actual valve internal connections depend on the selected centre condition.

5. Pressure-Control Valves

Pressure valves protect equipment, limit force, sequence operations, and maintain pressure.

Relief valves

A relief valve opens when system pressure reaches its setting and diverts flow to tank. Direct-acting relief valves are simple and fast for modest flow. Pilot-operated relief valves provide more accurate control and lower pressure override at higher flows. A relief valve is a safety component, not a normal means of controlling actuator speed.

Reducing valves

A pressure-reducing valve maintains a lower downstream pressure in a branch circuit. It is normally open and closes or throttles when downstream pressure reaches its setting. A check bypass is often incorporated to permit reverse free flow.

Sequence valves

A sequence valve permits a second operation only after the first circuit reaches a specified pressure. It is used, for example, to clamp a workpiece before a drilling cylinder advances. Correct drainage and check-valve arrangements are essential.

Counterbalance valves

A counterbalance valve holds an overrunning load, such as a vertical cylinder or winch. Pilot assistance reduces the pressure needed to lower the load. Incorrect settings can cause chatter, heat generation, or uncontrolled descent; the valve must be located close to the actuator where possible.

Unloading valves

An unloading valve diverts pump flow to tank at low pressure when the circuit does not require full pressure. This reduces heat in systems using fixed-displacement pumps.

6. Flow-Control Valves

Flow-control valves regulate actuator speed by controlling flow. A fixed restrictor gives a constant resistance but does not compensate for load or pressure variation. A pressure-compensated flow-control valve maintains approximately constant flow despite changes in pressure drop, within its operating range.

  • Meter-in: restricts inlet flow. It is suitable for resistive loads but may permit runaway with overrunning loads.
  • Meter-out: restricts outlet flow. It generally provides better control of overrunning loads and is commonly used with cylinders.
  • Bleed-off: diverts part of pump flow to tank; efficient only in appropriate load conditions.

Flow-control valves cause pressure loss and therefore heat. The power dissipated across a valve is

Ploss = ΔpvQ

where Δpv is the valve pressure drop and Q is flow through it. In practical units,

Ploss\,[kW] = \frac{Δpv\,[MPa]×Q\,[L/min]}{60}

For example, 5 MPa lost at 20 L/min produces 1.67 kW of heat. This heat must be removed by the reservoir, cooler, or both.

7. Check, Cartridge, and Logic Valves

A check valve permits flow in one direction and blocks reverse flow. Applications include load holding, pump isolation, anti-drainback protection, and hydraulic locking. Cracking pressure, leakage, flow capacity, and closing shock must be considered.

Pilot-operated check valves remain closed until pilot pressure opens them. They are used to lock cylinders in position, but pilot pressure must be sufficient under the actual load condition. Thermal expansion of trapped fluid can create dangerously high pressure; a pressure-relief function may be needed.

Cartridge valves are two-stage, screw-in or slip-in elements installed in manifolds. A large poppet provides high flow capacity with low pressure loss, while a small pilot valve controls opening. Cartridge systems reduce piping, improve compactness, and allow integrated logic functions. Their performance depends strongly on manifold passages, pilot connections, contamination control, and correct cavity dimensions.

Hydraulic logic valves use pressure signals to implement functions analogous to digital logic, although the signals are continuous pressures. Examples include:

  • AND function: an actuator receives flow only when two pilot conditions are present;
  • OR function: either of two pressure sources can initiate an operation;
  • NOT or inhibit function: a pilot signal prevents another operation;
  • sequence logic: one operation is completed before the next begins.

Logic circuits are valuable in presses, clamping systems, and safety interlocks. They must be analysed for pilot pressure, spring force, leakage, timing, and failure behaviour rather than treated as ideal switches.

8. Valve Selection and Circuit Analysis

Valve selection should follow the actuator duty rather than catalogue pressure alone. The principal checks are:

  1. Pressure rating: continuous, intermittent, peak, and case-drain pressures must be within manufacturer limits.
  2. Flow rating: the valve must pass the required flow without excessive pressure drop.
  3. Control characteristic: on/off, proportional, or servo control must match accuracy and response requirements.
  4. Leakage: spool valves may permit more leakage than poppet or seated valves.
  5. Response: switching time and dynamic bandwidth affect positioning and cycle time.
  6. Mounting and ports: manifold, subplate, flange, and pipe connections must withstand vibration and installation loads.
  7. Fluid compatibility: seals, coatings, and valve materials must suit the specified fluid.
  8. Contamination tolerance: filtration must match the most sensitive component, often a servo or proportional valve.

A circuit should be analysed in each operating state: start-up, extension, retraction, holding, emergency stop, and loss of electrical power. Questions include: What supports the load? Where does pump flow go? Can trapped fluid expand? What happens if a hose ruptures? Can the actuator coast or fall? Is the relief valve correctly located and adjusted?

9. Illustrative Case: Hydraulic Clamping and Drilling Cell

Background

This illustrative case concerns a machining cell in which a hydraulic cylinder clamps a workpiece before a hydraulic motor drives a drilling spindle. The clamp must generate 25 kN, extend 150 mm in 1.5 s, and hold securely while drilling. The drilling motor requires 12 kW at 1,200 rpm.

Problem analysis

The clamp requires an average speed of

v = \frac{0.150}{1.5} = 0.100\,m/s

Assuming a design pressure of 10 MPa and ignoring losses initially, the minimum cap-end area is

A = \frac{F}{p} = \frac{25,000}{10×106} = 0.0025\,m2

The corresponding theoretical bore is

D = \sqrt{\frac{4A}{π}} = 0.0564\,m

A standard 63 mm bore would be selected provisionally. Its cap-end area is approximately 0.00312 m², giving an ideal force of 31.2 kN at 10 MPa. This provides allowance for friction, but the final design must confirm the required clamping force at the actual valve and hose pressure losses.

Required clamp flow is

Q = Av = 0.00312×0.100 = 0.000312\,m3/s ≈ 18.7\,L/min

Approach and solution

A 4/3 directional valve controls the double-acting clamp cylinder. A pressure-reducing or pressure-control branch limits clamping force if the main system pressure is higher. A pilot-operated check valve mounted close to the cylinder holds the clamp during drilling. A sequence valve permits motor operation only after clamp pressure reaches its setting. The drilling motor is selected from its required torque:

T = \frac{P}{2πn}

For P = 12,000\,W and n = 1200/60 = 20\,rev/s,

T = \frac{12,000}{2π×20} = 95.5\,N·m

The motor and pump must be selected for the required torque, speed, efficiency, and pressure difference. The clamp and motor may not operate simultaneously unless the pump has adequate flow and the reservoir and cooler can dissipate the resulting losses.

Outcome and learning points

The proposed arrangement prevents drilling before secure clamping, limits clamp force, and retains the workpiece if the directional valve returns to centre. It also demonstrates that actuator sizing, valve logic, safety, and thermal analysis must be performed together. A cylinder chosen only from force would not establish safe sequencing or holding behaviour.

10. Limitations, Safety, and Contemporary Practice

Hydraulic systems store substantial energy. Unexpected movement can result from trapped pressure, accumulator discharge, gravity loads, thermal expansion, or a failed hose. Safe practice requires isolation, lockout and tagout, pressure verification, mechanical blocking of raised loads, guarding, and use of rated hoses and fittings. Design should follow applicable machinery, pressure-equipment, electrical, and occupational-safety standards in the relevant jurisdiction.

Common technical limitations include leakage, compressibility-related compliance, temperature-dependent viscosity, valve hysteresis, contamination, noise, and heat generation. Hydraulic fluid should be filtered, sampled, and maintained according to component cleanliness requirements. Excessive viscosity increases pressure loss; low viscosity increases leakage and wear.

Modern systems increasingly use electrohydraulic proportional valves, integrated sensors, digital controllers, load-sensing pumps, and condition-monitoring systems. AI can assist with anomaly detection from pressure, temperature, vibration, and leakage data, but it does not replace pressure-rated hardware, functional safety analysis, or competent engineering judgement. Cybersecurity becomes relevant when valves and controllers are networked.

Best practice is to:

  • size actuators from the complete load and motion profile;
  • use standard catalogue ratings and verify peak as well as continuous duty;
  • minimise unnecessary throttling and pressure drop;
  • place load-holding valves close to actuators;
  • provide filtration and cleanliness control;
  • consider failure modes and emergency states;
  • validate the design by calculation, simulation, testing, and inspection;
  • document settings, maintenance intervals, and safe isolation procedures.

Chapter Summary

Hydraulic actuators transform fluid power into linear or rotary mechanical output. Cylinder force depends on pressure and effective area, while speed depends on flow and area. Extension and retraction forces differ in double-acting cylinders because the rod reduces the effective area. Cylinder selection must also address buckling, side loading, cushioning, mounting, seals, environment, and feedback.

Rotary actuators provide limited-angle motion, whereas hydraulic motors provide continuous rotation. Motor torque is related to pressure difference and displacement; speed is related to flow and volumetric efficiency. Gear, vane, axial-piston, radial-piston, and orbital motors offer different compromises among cost, efficiency, pressure, speed, torque, and contamination tolerance.

Directional valves control motion. Pressure valves limit, reduce, sequence, unload, or counterbalance pressure. Flow valves regulate speed but produce heat when pressure is dissipated. Check and pilot-operated check valves control one-way flow and load holding. Cartridge and logic valves provide compact, high-flow, manifold-based control and sequencing.

Reliable hydraulic design integrates actuator sizing, valve selection, energy efficiency, contamination control, thermal management, safety, and failure analysis. The correct component is not merely one that meets nominal pressure; it must perform safely throughout the complete operating cycle.

Key Terms

Actuator: Device that converts hydraulic energy into mechanical motion.

Annular area: Effective piston area on the rod side of a cylinder.

Cartridge valve: Insert-type hydraulic valve installed in a manifold cavity.

Check valve: Valve that permits flow in one direction and blocks reverse flow.

Counterbalance valve: Pressure-control valve that prevents uncontrolled movement of an overrunning load.

Cylinder cushion: End-of-stroke deceleration arrangement that restricts exhaust flow.

Directional-control valve: Valve that starts, stops, or reverses fluid flow.

Flow-control valve: Valve used to regulate volumetric flow and actuator speed.

Hydraulic motor: Positive-displacement actuator producing continuous rotation.

Logic valve: Valve arrangement that performs pressure-based sequencing or logical functions.

Pilot-operated valve: Valve whose main element is controlled by a smaller pilot stage.

Pressure-compensated flow control: Flow control that maintains approximately constant flow despite pressure variation.

Pressure-reducing valve: Valve that maintains lower downstream pressure.

Relief valve: Valve that limits maximum system pressure by diverting flow.

Rotary actuator: Actuator producing limited-angle rotation.

Sequence valve: Valve that initiates a secondary operation after a pressure condition is reached.

Spool valve: Directional valve using a sliding cylindrical spool.

Volumetric efficiency: Ratio of useful delivered flow or displacement to theoretical displacement.

Review Questions

Short Answer Questions

  1. Why is the retraction force of a double-acting cylinder normally lower than its extension force at equal pressure?
  2. What is the primary function of a hydraulic relief valve?
  3. Distinguish between a rotary actuator and a hydraulic motor.
  4. Why is meter-out flow control often preferred for an overrunning load?
  5. What is the purpose of a pilot-operated check valve?

Long Answer Questions

  1. Explain the construction, operation, and selection criteria of a double-acting hydraulic cylinder.
  2. Compare gear, vane, axial-piston, radial-piston, and orbital hydraulic motors.
  3. Explain the operating principles and applications of relief, reducing, sequence, counterbalance, and unloading valves.
  4. Describe the centre conditions of a 4/3 directional-control valve and their circuit implications.
  5. Discuss the advantages and limitations of cartridge and hydraulic logic valves in industrial systems.

Analytical / Application Questions

  1. A cylinder must produce 40 kN at 12 MPa. Determine its theoretical bore and recommend additional checks before final selection.
  2. A vertical cylinder lowers an overrunning load and exhibits oscillation. Analyse possible causes involving flow control, counterbalance setting, pilot pressure, and trapped air.
  3. Design a conceptual hydraulic circuit in which a workpiece is clamped, drilling begins only after clamping pressure is reached, and the clamp remains secure during a power failure. Identify the required valves and explain each safety function.

Multiple Choice Questions with Answers

Question 1

A double-acting cylinder has a 100 mm bore. Ignoring losses, what extension force is produced at 10 MPa?

A. 7.85 kN

B. 31.4 kN

C. 78.5 kN

D. 100 kN

Correct Answer: C. 78.5 kN

Question 2

Which valve primarily limits maximum hydraulic system pressure?

A. Relief valve

B. Flow-control valve

C. Check valve

D. Sequence valve

Correct Answer: A. Relief valve

Question 3

For a cylinder controlling an overrunning load, which arrangement generally provides better speed control?

A. Meter-in control

B. Meter-out control

C. Unrestricted inlet flow

D. Open-centre control only

Correct Answer: B. Meter-out control

Question 4

A hydraulic motor produces continuous rotary motion, while a rotary actuator normally produces:

A. Only reciprocating linear motion

B. Limited-angle rotary motion

C. Electrical motion

D. Thermal motion

Correct Answer: B. Limited-angle rotary motion

Question 5

What is the ideal hydraulic power when pressure is 10 MPa and flow is 30 L/min?

A. 0.5 kW

B. 3 kW

C. 5 kW

D. 30 kW

Correct Answer: C. 5 kW

Question 6

Which valve permits flow in one direction and blocks reverse flow?

A. Check valve

B. Reducing valve

C. Sequence valve

D. Servo valve

Correct Answer: A. Check valve

Question 7

A pressure-reducing valve is intended to:

A. Increase downstream pressure above supply pressure

B. Maintain lower downstream pressure

C. Convert linear motion to rotary motion

D. Measure flow directly

Correct Answer: B. Maintain lower downstream pressure

Question 8

What is a principal advantage of cartridge valves?

A. They require no contamination control

B. They provide compact, high-flow manifold construction

C. They cannot be pilot operated

D. They always eliminate pressure losses

Correct Answer: B. They provide compact, high-flow manifold construction

Question 9

For a motor, increasing displacement at constant flow generally causes rotational speed to:

A. Increase

B. Decrease

C. Remain exactly unchanged

D. Become independent of flow

Correct Answer: B. Decrease

Question 10

Which component is especially appropriate for holding a vertical load and preventing uncontrolled descent?

A. Counterbalance valve

B. Fixed restrictor only

C. Open-centre valve only

D. Unloading valve

Correct Answer: A. Counterbalance valve

Hydraulics and Pneumatics
Chapter 5 of 15