Chapter 14
Fluid-System Design, Operation, and Asset Decisions
Bachelors Program in Machine Technology
Fluid Mechanics and Machinery
•
Bachelor
Fluid-System Design, Operation, and Asset Decisions
Introduction and context
Fluid machinery does not operate in isolation. A pump, fan, turbine, compressor, valve, pipe network, storage vessel, and control system form an interacting fluid system. The machine supplies energy, while the system determines how much flow can be delivered at a particular pressure or head. Consequently, selecting a pump from a catalogue without first defining the system curve is a common and costly engineering error.
Fluid-system design also extends beyond hydraulic sizing. A technically adequate installation must be operable, controllable, safe, maintainable, energy-efficient, compliant with applicable codes, and economically defensible over its complete life. Decisions made during layout and procurement influence decades of energy use, failure risk, environmental impact, and maintenance expenditure.
This chapter develops a structured approach to matching machines with systems, designing piping and controls, managing transients, and making asset decisions.
Learning objectives
By the end of this chapter, the reader should be able to:
Construct and interpret a system head curve and match it with a machine characteristic curve.
Select practical pipe sizes, valves, fittings, controls, and equipment arrangements.
Explain the causes and consequences of water hammer and other hydraulic transients.
Compare fixed-speed, throttled, bypassed, and variable-speed operation.
Evaluate reliability, maintainability, safety, regulatory compliance, lifecycle cost, and energy efficiency.
Recommend an asset decision using technical, economic, and operational evidence.
1. The system as an energy-and-flow model
1.1 Energy equation for a real fluid system
For steady, incompressible flow between section 1 and section 2, the extended Bernoulli equation is
Here, p is pressure, ρ is fluid density, g is gravitational acceleration, V is mean velocity, z is elevation, hp is pump head added, ht is turbine head removed, and hL is total head loss. The kinetic-energy correction factor α accounts for a non-uniform velocity profile. For turbulent flow in a reasonably developed pipe, it is often close to 1; for fully developed laminar flow in a circular pipe, it is 2.
The equation assumes a single-phase fluid, identifiable inlet and outlet sections, and time-averaged conditions. It must be modified for compressible flow, strongly unsteady flow, multiphase flow, or substantial heat and mass transfer.
If a pump transfers fluid from a suction reservoir to a discharge reservoir, both reservoir velocities are approximately zero and reservoir pressures may be atmospheric. The required pump head becomes
Hsys = Hstatic + hf + hm
where Hstatic is the elevation and pressure difference expressed as head, hf is distributed pipe friction loss, and hm is minor loss through entrances, exits, bends, valves, strainers, and fittings.
For a pipe of length L and diameter D, the Darcy–Weisbach friction loss is
hf = f (L/D) V2/(2g)
where f is the Darcy friction factor. It depends on Reynolds number and relative roughness. The Reynolds number is
Re = ρVD/μ = VD/ν
where μ is dynamic viscosity and ν is kinematic viscosity. For laminar flow in a circular pipe, f = 64/Re. For turbulent flow, f should be obtained from a validated correlation or the Moody diagram; the Colebrook–White relation is
1/√f = -2 log10(ε/(3.7D) + 2.51/(Re√f))
where ε is absolute roughness. This relation is implicit and applies to fully developed turbulent flow in commercial pipes.
Minor losses are commonly represented by
hm = ΣK V2/(2g)
where K is the dimensionless loss coefficient for each component. The velocity used must correspond to the pipe section for which that coefficient was obtained. Manufacturer data are preferable for valves, filters, check valves, and complex fittings.
1.2 The system curve
For a fixed layout and fluid, system head normally increases with flow because friction varies approximately with the square of velocity. A useful engineering representation is
Hsys(Q) = Hstatic + Ksys Q2
where Q is volumetric flow rate and Ksys is an aggregate resistance coefficient. This is an approximation: viscosity, valve position, flow regime, equipment characteristics, and parallel branches can make the curve depart from a simple quadratic form.
The static head is independent of flow in a reservoir-to-reservoir system, whereas friction and minor losses are flow-dependent. In a closed circulating loop with no elevation or pressure difference between endpoints, Hstatic may be zero, although pump head is still required to overcome friction.
1.3 The operating point
A machine characteristic curve gives the head supplied by a pump or fan at each flow rate under stated speed, impeller, fluid, and test conditions. The operating point is the intersection of the machine curve and system curve:
Hmachine(Q) = Hsys(Q)
At this point, the machine and system are in hydraulic equilibrium. The flow is not necessarily the design flow, because changes in fouling, valve position, fluid temperature, speed, or system configuration move one or both curves.
A pump should normally operate near its best efficiency point (BEP), while allowing for the required operating envelope. Operation far to the left of BEP can cause recirculation, vibration, heating, and radial thrust; operation far to the right can cause cavitation, motor overload, excessive velocity, or inadequate developed head.
Pump and system curves intersecting at the operating point
Figure: Pump and system curves intersecting at the operating point
Figure: The operating point is the intersection of the machine characteristic and system resistance curves.
2. Machine selection and system matching
2.1 Establishing the design envelope
Before selecting a machine, define:
normal, minimum, and maximum flow;
static elevation and pressure requirements;
fluid density, viscosity, temperature, solids, corrosiveness, and toxicity;
suction conditions and available net positive suction head;
expected future capacity and turndown;
operating hours and duty cycle;
installation environment, electrical supply, noise limits, and hazardous-area classification.
The selected machine should satisfy the worst credible duty without being grossly oversized. Oversizing often leads to throttling, inefficient operation, unstable control, and higher capital cost.
For pumps, available net positive suction head is commonly expressed as
NPSHA = pabs,s/(ρg) + Vs2/(2g) - pv/(ρg)
where pabs,s is absolute pressure at the pump suction reference, Vs is suction velocity, and pv is vapour pressure. The pump manufacturer provides NPSHR, the head required by the pump at a specified flow. A safe design requires NPSHA > NPSHR by an appropriate margin, considering uncertainty, temperature variation, and transient conditions. Pressure must be absolute in the vapour-pressure comparison.
2.2 Affinity laws
For geometrically similar centrifugal pumps operating with the same fluid and approximately similar efficiency,
Q ∝ N D3
H ∝ N2 D2
P ∝ ρ N3 D5
where N is rotational speed, D is impeller diameter, and P is shaft power. For the same pump with fixed impeller diameter, these reduce to Q2/Q1 = N2/N1, H2/H1 = (N2/N1)2, and P2/P1 = (N2/N1)3. These are approximation laws, not substitutes for manufacturer curves, especially over wide speed ranges or where viscosity and Reynolds-number effects are important.
Hydraulic power and shaft power are related by
Ph = ρgQH
Pshaft = ρgQH/ηp
where ηp is pump efficiency. Motor and drive losses must be included when estimating electrical input.
2.3 Parallel and series operation
Identical pumps in parallel increase available flow at a given head, while pumps in series increase head at a given flow. For parallel operation, heads are equal and flows add; for series operation, flows are equal and heads add. Real systems require checks for unequal pump characteristics, minimum-flow requirements, check-valve behavior, and control interaction.
A standby pump improves availability only if the suction and discharge arrangement, isolation valves, automatic start logic, power supply, and testing program are also reliable. Redundancy without maintainability can create false security.
3. Layout, pipe sizing, valves, and controls
3.1 Layout principles
A good layout minimizes unnecessary fittings, supports safe access, avoids air pockets in liquid lines, provides drains at low points and vents at high points where appropriate, and permits isolation of maintainable equipment. Pump suction piping deserves special attention: it should be short and direct, with adequate submergence, no abrupt reducers immediately at the suction flange, and a configuration that avoids swirl and uneven velocity distribution.
Pipe diameter is an economic decision. A larger pipe raises capital cost but reduces friction, noise, erosion, and pumping energy. A smaller pipe reduces initial cost but may produce high velocities, severe losses, water hammer sensitivity, and future capacity limitations. Design velocity limits depend on fluid, material, pressure, noise, erosion, and local standards; they should not be selected from a universal rule.
3.2 Valve functions
Valves should be selected by function rather than merely by nominal size:
Function
Typical equipment
Principal design concern
Isolation
Gate, ball, butterfly valve
Tight shutoff and maintainability
Throttling
Globe, characterized ball, control valve
Predictable controllability and cavitation
Non-return
Swing, lift, axial check valve
Closing dynamics and reverse flow
Pressure protection
Relief or safety valve
Set pressure, capacity, discharge routing
Air management
Air-release and vacuum valves
Air removal and vacuum prevention
Flow measurement
Orifice, magnetic, ultrasonic meter
Accuracy, range, installation conditions
A control valve is a deliberate resistance element. Its sizing should consider required flow coefficient, pressure drop, rangeability, noise, cavitation, actuator force, and failure position. A valve that is almost closed during normal operation may indicate an oversized pump or poor control strategy.
3.3 Control strategies
Fixed-speed throttling is simple and robust but dissipates excess energy across the valve. Bypass control protects minimum flow but can waste substantial energy and heat the fluid. Variable-frequency drives alter speed and can reduce energy use substantially in variable-flow applications, but they introduce harmonics, electromagnetic compatibility issues, motor insulation stresses, cooling concerns at low speed, and dependence on instrumentation and software.
Control design should specify the controlled variable, manipulated variable, sensor location, operating range, failure response, alarm limits, interlocks, and manual fallback. A control loop must not be judged only by its ability to reach a set point; stability, response time, actuator authority, and safe failure behavior are equally important.
4. Water hammer and hydraulic transients
4.1 Physical mechanism
Water hammer occurs when fluid velocity changes rapidly. A valve closure, pump trip, check-valve slam, column separation, or rapid demand change generates pressure waves that travel through the fluid and pipe wall. Consequences include pipe rupture, flange leakage, support damage, vibration, reverse rotation, and repeated fatigue.
For a sufficiently rapid change in velocity, the ideal Joukowsky pressure rise is
∆p = ρa∆V
or, in head form,
∆H = a∆V/g
where a is the pressure-wave speed and ∆V is the change in mean velocity. The wave speed depends on fluid compressibility, pipe elasticity, wall thickness, restraint, and geometry. The formula estimates the initial surge for a rapid change; it does not by itself model reflections, friction, cavitation, branched networks, or gradual valve motion.
The round-trip wave travel time for a pipeline of length L is approximately
tc = 2L/a
A closure time substantially shorter than this characteristic time is often treated as rapid for preliminary assessment. The distinction is not absolute in complex systems, and transient simulation is required for important or hazardous installations.
4.2 Mitigation
Risk-reduction measures include controlled valve closure, pump ramp-down, non-slam check valves, surge vessels, air chambers, relief valves, vacuum breakers, flywheels, soft starters, and properly located accumulators. The remedy must address both positive pressure and negative pressure. A device that limits a pressure spike may not prevent column separation or vacuum collapse.
Transient studies should define credible scenarios: power failure, emergency shutdown, valve malfunction, pump start, check-valve closure, loss of control signal, and blocked discharge. Results should be compared with pipe pressure ratings, support loads, equipment limits, and allowable vacuum conditions.
5. Reliability, maintenance, and safety
5.1 Reliability framework
Reliability is the probability that an item performs its required function for a stated time under stated conditions. Availability additionally depends on repair time and logistics. A useful operational approximation is
A = MTBF/(MTBF + MTTR)
where MTBF is mean time between failures and MTTR is mean time to repair. This expression assumes a stable renewal process and excludes planned downtime; it is a planning metric, not a complete reliability model.
Failure modes should be identified through failure modes and effects analysis (FMEA), hazard and operability studies (HAZOP), or reliability-centred maintenance (RCM). Typical pump failure modes include seal leakage, bearing damage, impeller erosion, cavitation, coupling misalignment, motor insulation failure, and blockage. Each should be linked to causes, consequences, detection methods, preventive tasks, and responsible personnel.
5.2 Maintenance strategy
Corrective maintenance is appropriate for non-critical, low-cost items where failure consequences are limited. Preventive maintenance uses time or usage intervals. Predictive or condition-based maintenance uses vibration, bearing temperature, motor current, oil analysis, seal leakage, pressure, and flow trends. Effective programs avoid both neglect and unnecessary intervention.
Spare parts should be classified by criticality, lead time, obsolescence risk, and interchangeability. A cheap seal with a long procurement delay may deserve more attention than an expensive bearing available locally.
5.3 Safety and governance
Design must address pressure containment, rotating machinery guarding, electrical isolation, confined spaces, chemical exposure, hot surfaces, noise, lifting, and stored energy. Lockout/tagout or an equivalent energy-isolation process is essential before maintenance. Relief discharge must be routed to a safe location, and drain or vent points must not expose personnel to hazardous fluid.
Regulatory compliance may involve pressure-vessel rules, electrical and hazardous-area requirements, environmental discharge permits, water-quality legislation, occupational safety law, fire codes, and machinery standards. The exact obligations depend on jurisdiction and service. Compliance is not achieved by citing a standard alone; design records, inspection, testing, certification, operating procedures, and management of change are also required.
6. Lifecycle cost and energy decisions
Initial purchase price is only one component of asset cost. A lifecycle-cost model may be expressed as
where the terms represent initial, installation, energy, maintenance, downtime, environmental, disposal, and residual-value costs. For alternatives with costs occurring at different times, discounted present value is more appropriate:
PV = Σ(Ct/(1+r)t)
where Ct is the cost in year t, r is the discount rate, and the summation covers the analysis period. Energy prices, operating hours, discount rate, inflation treatment, and residual value must be stated clearly.
For a pump operating at constant duty, annual electrical energy is approximately
E = Pe t
where Pe is electrical input power and t is operating time. If power is measured in kilowatts and time in hours, E is in kilowatt-hours. Small efficiency differences can dominate lifecycle cost in continuously operated systems.
Energy efficiency should be pursued at system level. Reducing unnecessary pressure drop, selecting an appropriate pipe diameter, eliminating bypass flow, improving pump control, repairing leaks, cleaning strainers, and maintaining correct alignment can be more effective than replacing a machine with a marginally more efficient model.
7. Worked design example
An illustrative water-transfer system moves water from an open reservoir to a second reservoir. The static elevation difference is 18 m. The design flow is 0.060 m³/s through 120 m of commercial steel pipe with internal diameter 0.20 m. Assume total minor-loss coefficient ΣK = 5.0, water density 998 kg/m³, dynamic viscosity 1.0 × 10⁻³ Pa·s, g = 9.81 m/s², and friction factor f = 0.020.
The pipe area is
A = πD2/4 = π(0.20)2/4 = 0.0314 m2
Thus velocity is
V = Q/A = 0.060/0.0314 = 1.91 m/s
The Reynolds number is approximately
Re = ρVD/μ = (998)(1.91)(0.20)/(0.001) ≈ 3.81 × 105
so the flow is turbulent. Distributed loss is
hf = 0.020(120/0.20)(1.912/(2×9.81)) ≈ 2.23 m
Minor loss is
hm = 5.0(1.912/(2×9.81)) ≈ 0.93 m
Required pump head is therefore
H = 18 + 2.23 + 0.93 = 21.16 m
If pump efficiency is 78%, hydraulic power is
Ph = ρgQH = (998)(9.81)(0.060)(21.16) ≈ 12.43 kW
and shaft power is
Pshaft = 12.43/0.78 ≈ 15.9 kW
A motor would normally be selected after considering motor efficiency, service factor, starting conditions, maximum-flow power, ambient conditions, and applicable electrical standards. The pump catalogue must be checked at the actual system intersection, not merely at the nominal design point.
8. Illustrative case: modernization of a municipal booster station
Background
A fictional municipal booster station contains two fixed-speed centrifugal pumps. Operators report fluctuating discharge pressure, frequent seal failures, high electricity consumption, and occasional pipeline vibration after power interruptions. One pump is normally operated while the second is a standby.
Problem and analysis
Field measurements show that the installed pumps are substantially oversized for normal demand. Operators control pressure by throttling a discharge valve. The standby check valve closes abruptly after trips. The suction pipe contains a high point where air accumulates, and the emergency generator causes rapid restart after some outages. Maintenance records are incomplete, so failures cannot be correlated reliably with operating conditions.
A system-curve study confirms that the normal operating point lies far from BEP. A transient calculation identifies a pressure rise during rapid check-valve closure and a low-pressure event at the suction high point. The risk is therefore not a single faulty component but an interacting design, control, and maintenance problem.
Approach and solution
The utility adopts a staged intervention:
install calibrated pressure and flow measurement;
replace the abrupt-closing check valve with a hydraulically suitable non-slam design;
add controlled pump acceleration and deceleration;
convert one pump to variable-speed operation while retaining the second for peak demand and standby service;
install an air-release device at the high point after verifying safe discharge arrangements;
revise minimum-flow protection and emergency shutdown logic;
establish vibration, seal-leakage, and motor-current condition monitoring;
update isolation, lockout, inspection, and management-of-change procedures.
Outcome
In this illustrative case, the revised system reduces throttling losses and pressure fluctuation, while the transient protection reduces mechanical stress. The actual financial result depends on tariffs, operating hours, equipment cost, and financing assumptions; it should be demonstrated with measured baseline and post-project data rather than assumed savings.
Learning points
The case demonstrates that an energy project can also be a reliability and safety project. Instrumentation is valuable not only for control but also for diagnosing degradation. Finally, a variable-speed drive is not a universal remedy: it must be integrated with appropriate hydraulic protection, motor compatibility, controls, cybersecurity, and maintenance capability.
9. Contemporary tools and professional practice
Digital twins, supervisory control and data acquisition (SCADA), wireless sensors, and machine-learning models can support anomaly detection and remaining-useful-life estimation. Their value depends on sensor quality, representative failure data, secure communications, transparent alarm logic, and competent human review. Artificial intelligence should assist engineering judgement rather than silently override safety interlocks or statutory requirements.
A defensible design process maintains a traceable basis of design: assumptions, fluid properties, design cases, calculations, equipment curves, valve data, transient scenarios, standards, risk assessments, drawings, test results, and approval records. Commissioning should include flushing, pressure testing, rotation checks, instrument calibration, control-loop testing, performance verification, and operator training. Changes after commissioning should be controlled because altered valves, set points, pipe routes, or software can invalidate the original analysis.
Challenges and limitations
System curves may be uncertain because roughness, fouling, valve coefficients, demand, and fluid properties change with time. Manufacturer curves may be based on test conditions that differ from site conditions. Simplified water-hammer formulas are useful for screening but cannot replace network transient analysis in critical systems. Lifecycle-cost calculations are sensitive to energy prices, discount rates, operating hours, and failure assumptions. Reliability metrics can be misleading when failure reporting is incomplete. Finally, compliance requirements vary by jurisdiction and service, so engineers must verify current legal and standard-setting requirements rather than relying on outdated lists.
Best-practice design checklist
Define normal, minimum, maximum, upset, and future operating cases.
Draw the complete hydraulic boundary, including valves, instruments, drains, vents, bypasses, and standby equipment.
Calculate static head, distributed losses, minor losses, and equipment losses consistently.
Match the system curve with a machine curve and check the full operating envelope.
Verify NPSH, minimum flow, motor power, pressure ratings, and transient loads.
Design controls for normal operation, failure, manual operation, and safe shutdown.
Consider maintainability, access, isolation, lifting, spares, and inspection.
Compare alternatives using lifecycle cost and measured energy demand.
Document assumptions, standards, verification tests, and management of change.
Chapter Summary
Fluid machinery and its piping network must be designed as one system. The extended Bernoulli equation, Darcy–Weisbach loss model, minor-loss coefficients, and machine characteristic curves provide the foundation for predicting operating points. Pumps should be selected for the actual duty envelope, acceptable NPSH margin, efficient operation, and realistic future demand.
Layout and valve choices affect friction, controllability, safety, and maintenance. Fixed-speed throttling, bypassing, and variable-speed control have different energy and reliability consequences. Rapid changes in velocity generate pressure waves; water-hammer assessment must consider both positive surge and low-pressure events. Reliability-centred maintenance, condition monitoring, proper isolation, and well-designed redundancy improve availability.
Asset decisions should use lifecycle cost rather than purchase price alone. Energy, downtime, maintenance, environmental impact, compliance, and disposal all matter. Digital monitoring and AI can strengthen decisions when supported by sound data, secure systems, and accountable engineering judgement. The professional objective is not merely a machine that works, but a fluid system that remains safe, efficient, controllable, maintainable, and compliant throughout its life.
Key Terms
System curve: Relationship between required system head and flow rate.
Machine characteristic curve: Relationship between machine head or pressure rise and flow rate.
Operating point: Intersection of the machine curve and system curve.
Static head: Elevation and pressure difference independent of flow in the defined system.
Darcy–Weisbach equation: Relation used to calculate distributed pipe-friction loss.
Minor loss: Local loss caused by fittings, valves, entrances, exits, and equipment.
Reynolds number: Dimensionless ratio indicating the relative importance of inertial and viscous effects.
Best efficiency point (BEP): Pump operating condition at which hydraulic efficiency is greatest.
NPSH available: Suction pressure head available above liquid vapour-pressure head.
NPSH required: Suction head required by a pump to avoid unacceptable cavitation at a stated duty.
Affinity laws: Approximate scaling relationships for geometrically similar turbomachines.
Water hammer: Pressure transient produced by rapid fluid-velocity change.
Joukowsky relation: Approximate pressure-rise relation for rapid velocity change in an elastic pipeline.
Control valve: Variable-resistance device used to regulate flow, pressure, level, or temperature.
FMEA: Structured analysis of failure modes, effects, causes, and controls.
Availability: Fraction of required time during which an asset is capable of performing its function.
Lifecycle cost: Total discounted or undiscounted cost of owning and operating an asset.
Condition-based maintenance: Maintenance initiated by evidence of equipment condition or degradation.
Management of change: Formal process for evaluating and authorizing modifications to a system.
Review Questions
Short Answer Questions
What is the physical meaning of the intersection of a pump curve and a system curve?
Distinguish static head from friction head.
Why must absolute pressure be used when evaluating NPSH?
State two causes of water hammer.
What is the purpose of a non-return valve?
Long Answer Questions
Explain how the Darcy–Weisbach equation and minor-loss coefficients are used to construct a system curve.
Discuss the advantages and limitations of fixed-speed throttling, bypass control, and variable-speed control.
Explain the design and operational factors that determine pump reliability.
Describe a systematic approach to water-hammer assessment and mitigation.
Explain why lifecycle cost can justify a higher initial equipment price.
Analytical / Application Questions
A pump curve intersects a system curve below the required design flow. Identify at least three technically different remedies and explain the consequences of each.
A long water pipeline experiences a power-failure trip and subsequent check-valve slam. Using the Joukowsky relation conceptually, identify the variables that control the pressure surge and propose a verification plan.
Compare two pump alternatives: one has lower purchase cost but lower efficiency and no speed control; the other has higher purchase cost, higher efficiency, and a variable-frequency drive. Specify the operating, economic, reliability, and compliance data required before making the asset decision.
Multiple Choice Questions with Answers
Question 1
What defines the operating point of a pump in a piping system?
A. The point of maximum motor speed
B. The intersection of the machine curve and system curve
C. The point of zero friction loss
D. The rated flow printed on the pump nameplate
Correct Answer: B. The intersection of the machine curve and system curve
Question 2
Which equation is used for distributed friction loss in a pipe?
A. Darcy–Weisbach equation
B. Joukowsky equation
C. Affinity law for power
D. Continuity equation alone
Correct Answer: A. Darcy–Weisbach equation
Question 3
In the relation ∆p = ρa∆V, what does a represent?
A. Pipe cross-sectional area
B. Pump acceleration
C. Pressure-wave speed
D. Valve opening angle
Correct Answer: C. Pressure-wave speed
Question 4
For a centrifugal pump with fixed impeller diameter, if speed is increased by 10%, approximate head changes by a factor of:
A. 1.10
B. 1.21
C. 1.33
D. 0.91
Correct Answer: B. 1.21
Question 5
Which condition most directly increases the risk of cavitation at a pump suction?
A. Higher available absolute suction pressure
B. Lower fluid vapour pressure
C. NPSH available falling below NPSH required
D. Reduced suction-pipe velocity with no other change
Correct Answer: C. NPSH available falling below NPSH required
Question 6
Which control method generally dissipates excess pump head as pressure loss across a valve?
A. Discharge throttling
B. Impeller trimming only
C. Reservoir elevation reduction
D. Improved pipe alignment
Correct Answer: A. Discharge throttling
Question 7
A pipeline of length L has pressure-wave speed a. The approximate round-trip wave travel time is:
A. L/a
B. a/L
C. 2L/a
D. 2aL
Correct Answer: C. 2L/a
Question 8
Which measure is most directly associated with condition-based maintenance?
A. Replacing every bearing after exactly one month
B. Inspecting vibration and bearing-temperature trends
C. Ignoring low-level alarms
D. Increasing nominal pipe diameter
Correct Answer: B. Inspecting vibration and bearing-temperature trends
Question 9
If hydraulic power is 12 kW and pump efficiency is 0.75, approximate shaft power is:
A. 9 kW
B. 12 kW
C. 16 kW
D. 24 kW
Correct Answer: C. 16 kW
Question 10
Which statement best describes lifecycle cost?
A. It is only the equipment purchase price
B. It includes relevant ownership, energy, maintenance, downtime, and disposal costs
C. It excludes energy because energy is an operating issue
D. It is always equal to discounted capital cost
Correct Answer: B. It includes relevant ownership, energy, maintenance, downtime, and disposal costs