Fluid Mechanics and Machinery

Chapter 5
Flow Measurement, Experimentation, and Uncertainty

Bachelors Program in Machine Technology
Fluid Mechanics and Machinery   •   Bachelor

Flow Measurement, Experimentation, and Uncertainty

Introduction

The measurement of pressure, velocity, discharge, and fluid level is central to the design and operation of pumps, turbines, pipelines, process equipment, hydraulic structures, and automated manufacturing systems. Although conservation equations provide theoretical predictions, engineering decisions depend on measured data. A flowmeter that is poorly installed, incorrectly calibrated, or used outside its operating range can produce errors large enough to invalidate an otherwise sound design.

Flow measurement therefore combines fluid mechanics, instrumentation, experimental method, calibration, statistics, and engineering judgement. This chapter examines conventional instruments—including pressure gauges, manometers, Pitot tubes, Venturi meters, orifice meters, nozzles, rotameters, and weirs—and introduces modern electronic sensors. It also develops methods for calibration, uncertainty estimation, and assessment of data quality.

Learning Objectives

After studying this chapter, students should be able to:

  1. Explain the operating principles and limitations of common pressure and flow instruments.
  2. Select an appropriate instrument for a specified fluid, flow range, accuracy, and installation.
  3. Apply continuity, Bernoulli, momentum, and calibration relationships to measured flow.
  4. Design and interpret a basic flow-measurement experiment.
  5. Distinguish accuracy, precision, sensitivity, resolution, repeatability, and uncertainty.
  6. Estimate combined uncertainty using sensitivity coefficients and root-sum-square methods.
  7. Identify systematic and random errors and recommend methods for reducing them.
  8. Evaluate data quality and communicate measurement results professionally.

1. Measurement Foundations

1.1 Flow variables

The volumetric flow rate is the volume passing a section per unit time:

Q = dV/dt = A V̄

Here, Q is volumetric flow rate in m³/s, V is volume in m³, t is time in s, A is cross-sectional area in m², and V̄ is the area-averaged velocity in m/s. The mass flow rate is:

ṁ = ρQ

where ṁ is mass flow rate in kg/s and ρ is fluid density in kg/m³. For an incompressible fluid in steady flow, conservation of mass gives:

A₁V₁ = A₂V₂

For compressible flow, the more general relation is ρ₁A₁V₁ = ρ₂A₂V₂.

1.2 Pressure measurement

Absolute pressure is measured relative to a perfect vacuum. Gauge pressure is measured relative to local atmospheric pressure:

pabs = pg + patm

A vacuum pressure is commonly reported as a negative gauge pressure. Pressure instruments must be selected according to range, fluid compatibility, temperature, pulsation, and required accuracy.

A piezometer measures pressure head in a liquid open to the atmosphere. A differential manometer measures the pressure difference between two points. For a simple water manometer connected to points at the same elevation, a measured liquid-column difference h gives:

∆p = ρg h

where ∆p is pressure difference in Pa, ρ is the manometer-fluid density in kg/m³, and g is gravitational acceleration, approximately 9.81 m/s². If the pressure taps have different elevations or the pipe fluid and manometer fluid differ, hydrostatic pressure changes in both fluids must be included.

Mechanical Bourdon gauges convert pressure-induced tube deformation into pointer movement. Diaphragm and bellows instruments are useful for low pressures and differential measurements. Electronic pressure transducers commonly use strain gauges, piezoresistive elements, capacitive diaphragms, or resonant sensing elements. Their output may be voltage, current—often 4–20 mA—or a digital signal.

Important performance terms are:

  • Range: minimum to maximum measurable value.
  • Span: upper range value minus lower range value.
  • Resolution: smallest discernible change.
  • Sensitivity: output change per unit input change.
  • Accuracy: closeness to the accepted reference value.
  • Precision: closeness of repeated readings to one another.
  • Hysteresis: different readings for increasing and decreasing input.
  • Drift: change in indication over time under unchanged conditions.

Accuracy and precision are not interchangeable. A sensor may be precise but biased because of an incorrect calibration.

2. Velocity and Flow-Rate Instruments

2.1 Pitot and Pitot-static tubes

A Pitot tube brings fluid to rest at an opening facing the flow. The resulting stagnation pressure is compared with static pressure. Applying Bernoulli’s equation between the free stream and stagnation point, under steady, incompressible, inviscid conditions along a streamline:

V = Cp √(2∆p/ρ)

Here, V is local velocity, ∆p is stagnation-to-static pressure difference, ρ is density, and Cp is the Pitot coefficient. For an ideal tube, Cp = 1; a calibrated instrument may have a coefficient close to, but not exactly, unity.

A Pitot-static tube measures local velocity rather than directly measuring discharge. To obtain discharge, the velocity distribution across the section must be known or sampled. This makes Pitot tubes useful for air-flow surveys, duct testing, and velocity profiling, but less convenient than an integrated flowmeter in a small liquid pipeline. They require alignment with the flow and are sensitive to blockage, turbulence, and placement near walls.

2.2 Venturi meter

A Venturi meter consists of a converging section, throat, and gradual diffuser. The pressure decreases as velocity increases through the throat. For horizontal, steady, incompressible flow, combining continuity with Bernoulli’s equation gives the ideal discharge. The actual discharge is:

Q = Cd A₂ √[2∆p / {ρ(1 − β⁴)}]

where A₂ is throat area, β = d₂/d₁ is the throat-to-inlet diameter ratio, ∆p = p₁ − p₂ is the measured pressure difference, ρ is density, and Cd is the discharge coefficient. The equation assumes negligible elevation difference, a single-phase fluid, and a sufficiently developed flow. For nonhorizontal installation, the pressure term must be corrected for elevation:

∆pe = (p₁ − p₂) + ρg(z₁ − z₂)

where z denotes elevation. Venturi meters have low permanent pressure loss and good repeatability, but they are relatively large and costly.

2.3 Orifice meters

An orifice meter uses a thin plate with a sharp-edged opening. Flow contracts downstream of the plate, forming a vena contracta. The same general relationship is used:

Q = Cd Ao √[2∆p / {ρ(1 − β⁴)}]

where Ao is orifice area and β = do/d1. The discharge coefficient depends on Reynolds number, diameter ratio, pressure-tap arrangement, plate geometry, and edge condition. Orifice meters are inexpensive and compact, but they cause substantial permanent head loss and are sensitive to incorrect installation, fouling, and plate wear.

A differential-pressure transmitter often measures the pressure difference. Since flow is approximately proportional to the square root of differential pressure, the transmitter or control system must apply square-root extraction:

Q ∝ √∆p

Using a linear relationship between indicated flow and ∆p produces serious errors, especially at low flow.

2.4 Flow nozzles

A flow nozzle has a smooth converging profile and is intermediate between a Venturi meter and an orifice plate. It tolerates higher velocity and temperature than many orifice installations and generally has a lower pressure loss than an orifice, though greater cost and loss than a Venturi meter. Nozzles are common in high-speed water and steam systems.

2.5 Rotameters

A rotameter is a variable-area meter consisting of a tapered transparent or metal tube and a float. As flow rises, the float moves upward until upward fluid force, weight, and buoyancy balance. The float position is read against a calibrated scale.

A rotameter must normally be installed vertically with upward flow. Its scale is specific to fluid density, viscosity, pressure, temperature, float material, and tube geometry. It is simple, provides local visual indication, and requires little energy, but it is less suitable for dirty fluids, pulsating flow, remote monitoring, or highly accurate custody measurement. A rotameter should not be assumed to read correctly merely because the float is moving.

2.6 Weirs and open-channel measurement

A sharp-crested rectangular weir measures flow by relating upstream head above the crest to discharge. For an ideal rectangular weir of width b, with head H measured upstream and sufficiently away from the drawdown region:

Qideal = (2/3)b√(2g)H^(3/2)

Actual discharge is represented by:

Q = Cd (2/3)b√(2g)H^(3/2)

The coefficient incorporates contraction, viscosity, approach conditions, and crest geometry. The relation applies only when the crest is sharp and the upstream and downstream conditions satisfy the required free-discharge assumptions. Submergence, sediment, waves, poor approach flow, and an incorrectly located head gauge can cause large errors.

A triangular or V-notch weir is especially useful for smaller discharges. For an ideal V-notch of angle θ,

Qideal = (8/15)√(2g) tan(θ/2) H^(5/2)

The actual relation again requires a calibrated discharge coefficient and controlled approach conditions.

3. Modern Flow Sensors

Electromagnetic flowmeters use Faraday’s law: a conductive fluid moving through a magnetic field generates a voltage proportional to velocity. They have no obstruction and are effective for conductive liquids, slurries, and corrosive fluids, but cannot measure insulating liquids and require a full pipe.

Ultrasonic meters use transit-time or Doppler principles. Transit-time meters compare upstream and downstream travel times and are suited to relatively clean liquids. Doppler meters depend on reflections from particles or bubbles and are useful where suspended material is present. Clamp-on ultrasonic meters simplify installation but depend strongly on pipe material, wall thickness, coupling, and sensor placement.

Vortex meters infer flow from vortex-shedding frequency behind a bluff body. They are useful for liquids, gases, and steam, but require adequate Reynolds number and are sensitive to vibration and pulsation.

Coriolis meters measure mass flow from tube deflection caused by Coriolis forces. They can provide highly accurate mass flow and density, although they are comparatively expensive and may introduce pressure loss.

Thermal mass meters measure heat transfer from a heated element to a moving gas. They are primarily used for gases and require compensation for gas composition, pressure, and temperature.

Modern installations frequently connect sensors to programmable logic controllers, supervisory systems, and industrial networks. Digital recording improves traceability, but it does not remove errors caused by poor installation, unsuitable process conditions, or incorrect configuration.

4. Experimental Method and Installation

A credible experiment begins with a measurement objective. The investigator should specify the measurand—for example, steady volumetric flow of water at a stated temperature—the expected range, allowable uncertainty, sampling interval, and reference method.

A typical flow-meter experiment includes a reservoir, pump, straight test section, flowmeter, pressure taps, control valve, and collection or reference system. Flow disturbances from elbows, valves, reducers, pumps, and partially open valves can produce asymmetric velocity profiles. Manufacturer instructions and relevant standards should be followed for minimum straight lengths and installation orientation.

Before collecting data, inspect fittings, remove air from liquid systems, check for leaks, confirm that the pipe is full, verify sensor zero, and allow readings to stabilize. Change the flow in several steps across the operating range. At each point, record indicated flow, reference flow, pressure, temperature, density, time, and relevant environmental conditions. Repeating measurements at selected points reveals random variation and hysteresis.

For a volumetric tank calibration, the reference flow is determined by collecting a known volume over a measured time:

Qref = Vc/tc

where Vc is collected volume and tc is collection time. The start and stop timing should be synchronized with the flow-diversion mechanism; otherwise reaction time becomes a significant error.

A calibration curve may be represented by a linear model when justified:

y = a + bx

Here, x is the instrument indication, y is the reference value, a is an offset, and b is sensitivity. A linear model should not be imposed if residuals show curvature. For many differential-pressure meters, a model involving √∆p is physically more appropriate.

5. Error, Uncertainty, and Data Quality

5.1 Error versus uncertainty

Measurement error is the difference between a measured value and the unknown true value. Since the true value is not normally known exactly, error cannot usually be determined directly. Uncertainty is a quantified indication of doubt associated with a measurement result.

Systematic effects produce bias and include zero offset, calibration error, installation error, leakage, incorrect density, and thermal drift. Repeated measurements do not eliminate bias. Random effects cause readings to scatter and can be reduced, though not entirely eliminated, by repetition and averaging.

A result should be reported as:

x = x̄ ± U

where x̄ is the best estimate and U is an expanded uncertainty associated with a stated coverage level, commonly approximately 95% when a suitable coverage factor is used.

5.2 Type A and Type B evaluation

Type A uncertainty is evaluated statistically from repeated observations. For n observations xi, the mean is:

x̄ = (1/n)∑xi

The experimental standard deviation is:

s = √[∑(xi − x̄)²/(n − 1)]

The standard uncertainty of the mean is:

uA = s/√n

This reduction applies to independent random variation. It does not remove a common calibration bias.

Type B uncertainty is evaluated from specifications, calibration certificates, resolution, previous data, or engineering judgement. If an error limit of ±a is assumed equally likely throughout the interval, the standard uncertainty is:

uB = a/√3

Other probability distributions require different divisors; the assumed distribution must be documented.

5.3 Propagation of uncertainty

If a result y depends on independent input quantities x₁, x₂, …, xn, the combined standard uncertainty is approximated by:

uc(y) = √[∑(∂y/∂xi)²u²(xi)]

The derivatives are sensitivity coefficients. Correlation terms must be added when inputs are correlated.

For a product or power law, y = Cx₁a x₂b, the relative uncertainty approximation is:

[uc(y)/y]² ≈ a²[u(x₁)/x₁]² + b²[u(x₂)/x₂]²

provided the inputs are independent and uncertainties are sufficiently small.

Worked Example: uncertainty in a tank calibration

A tank calibration collects Vc = 0.500 ± 0.001 m³ over tc = 20.0 ± 0.1 s. The uncertainties are standard uncertainties and are independent. The reference flow is:

Q = Vc/tc = 0.500/20.0 = 0.0250 m³/s

For Q = Vc/tc, the relative combined uncertainty is:

uc(Q)/Q = √[(0.001/0.500)² + (0.1/20.0)²]
= √[(0.002)² + (0.005)²]
= 0.00539

Therefore:

uc(Q) = 0.0250 × 0.00539 = 0.000135 m³/s

The result may be reported as Q = (0.02500 ± 0.00014) m³/s for approximately one standard uncertainty, subject to appropriate rounding and a stated confidence or coverage convention. The timing uncertainty dominates because its relative value is 0.5%, compared with 0.2% for volume.

5.4 Assessing data quality

Useful quality indicators include repeatability, percentage error relative to a reference, residual plots, drift, signal stability, and uncertainty relative to the engineering tolerance. Percentage error against a reference is:

% error = 100(ymeas − yref)/yref

This is an observed comparison, not a complete uncertainty statement. A calibration plot should show measured and reference values, fitted relation, residuals, and uncertainty bands where available. Residuals randomly scattered around zero support a model; curvature, trends, or sudden changes indicate model inadequacy, drift, or operating faults.

Resolution must be distinguished from uncertainty. A digital display reading to 0.01 L/s may still have an uncertainty of 0.10 L/s. Conversely, reporting many decimal places does not create accuracy.

6. Worked Flow-Meter Example

Water flows through a horizontal Venturi meter with inlet diameter d₁ = 0.100 m, throat diameter d₂ = 0.050 m, pressure difference ∆p = 18.0 kPa, density ρ = 998 kg/m³, and discharge coefficient Cd = 0.98.

The area ratio is β = 0.050/0.100 = 0.50, and the throat area is:

A₂ = πd₂²/4 = π(0.050)²/4 = 0.001963 m²

Thus:

Q = 0.98(0.001963)√[2(18,000)/{998(1 − 0.50⁴)}]

Since 1 − 0.50⁴ = 0.9375,

Q ≈ 0.98(0.001963)√(36,000/935.6)
≈ 0.98(0.001963)(6.20)
≈ 0.0119 m³/s

The corresponding mass flow is:

ṁ = ρQ = 998(0.0119) ≈ 11.9 kg/s

The calculation assumes steady, single-phase flow, a full pipe, correct pressure-tap locations, negligible elevation difference, and a valid discharge coefficient. If these assumptions are not met, numerical precision in the calculation does not imply measurement accuracy.

7. Illustrative Case: Diagnosing a Disagreement Between Flowmeters

Background

A manufacturing plant uses water to cool a machining line. A newly installed electromagnetic flowmeter indicates 42 m³/h, while a calibrated tank-and-stopwatch test indicates 38 m³/h. Production staff initially suspect a defective electronic meter.

Problem analysis

The engineering team verifies that the liquid is electrically conductive and that the pipe is full. The electromagnetic meter has a valid calibration certificate. However, the meter is installed immediately downstream of a partially open control valve, with only two pipe diameters of straight length. The manufacturer recommends a substantially longer undisturbed section.

A zero check with the pump stopped is satisfactory. Repeated tank tests give 38.0, 38.2, 37.9, and 38.1 m³/h. The mean is 38.05 m³/h and the scatter is small. This indicates good repeatability of the reference method. Inspection also finds air bubbles entering intermittently through a leaking suction connection.

Approach and solution

The meter is relocated to a full-pipe section downstream of a straightener, the suction leak is repaired, and the line is vented. After stabilization, the electromagnetic meter reads 38.1 m³/h while the tank reference reads 38.0 m³/h. The remaining difference is within the combined uncertainty of the two methods.

Outcome and learning points

The original disagreement was caused by installation and two-phase effects rather than a simple electronic failure. The case demonstrates that:

  • instrument selection cannot be separated from installation;
  • repeatability does not prove correctness;
  • a reference measurement is essential for diagnosis;
  • air entrainment can affect both hydraulic behaviour and sensor indication;
  • calibration certificates do not guarantee performance in every installation.

8. Limitations, Safety, and Professional Practice

Flow experiments involve pressurized systems, rotating pumps, hot fluids, electrical supplies, and sometimes hazardous chemicals. Pressure ratings, isolation procedures, guarding, spill control, and electrical protection are mandatory. Never loosen a pressure connection before depressurizing and draining the system.

Standards and manufacturer procedures should be used for meter installation, calibration, uncertainty evaluation, and traceability. A professional report should state the instrument identity, range, calibration status, fluid properties, environmental conditions, method, raw observations, calculations, uncertainty, deviations from procedure, and final conclusion.

Ethically, data must not be selectively omitted merely because it disagrees with a preferred result. Outliers may be rejected only with a documented physical or procedural reason. Automated systems and AI-based analytics can detect drift, classify abnormal signals, and estimate soft-sensor values, but they require validated models, traceable reference data, cybersecurity controls, and human oversight. A prediction is not a substitute for an independently verified measurement when safety or regulatory compliance is involved.

Best-Practice Checklist

  1. Define the measurand and required accuracy before selecting an instrument.
  2. Match the instrument to fluid properties, range, temperature, pressure, and conductivity.
  3. Follow installation requirements for orientation, pipe fullness, grounding, and straight length.
  4. Check zero, leaks, air entrainment, and signal stability before recording data.
  5. Use a traceable reference method for calibration.
  6. Collect repeated observations across the operating range.
  7. Separate bias investigation from random-error analysis.
  8. Propagate important input uncertainties and identify the dominant contributors.
  9. Examine residuals and document deviations from assumptions.
  10. Report units, significant figures, uncertainty, and coverage information clearly.

Chapter Summary

Flow measurement applies conservation of mass, Bernoulli’s equation, hydrostatics, and calibration principles to determine pressure, velocity, volumetric flow, mass flow, and open-channel discharge. Pressure gauges and manometers provide direct pressure information, while Pitot tubes measure local velocity. Venturi meters, nozzles, and orifice meters infer discharge from differential pressure; rotameters use variable area; weirs relate head to open-channel flow. Electromagnetic, ultrasonic, vortex, Coriolis, and thermal meters extend measurement capability for specialized fluids and industrial automation.

Reliable experimentation requires defined measurands, suitable installation, stable operating conditions, traceable reference methods, repeated observations, and complete documentation. Error describes deviation from a reference, whereas uncertainty quantifies doubt in the result. Type A uncertainty comes from statistical analysis of repeated data; Type B uncertainty comes from specifications, calibration information, resolution, and engineering judgement. Sensitivity coefficients and root-sum-square propagation combine uncertainty contributions. Sound engineering practice reports both the measured value and its uncertainty and treats data quality, safety, ethics, and traceability as integral parts of measurement.

Key Terms

Accuracy: Closeness of a measurement to an accepted reference value.

Calibration: Comparison and, when appropriate, adjustment of an instrument against a traceable reference.

Cavitation: Formation and collapse of vapour cavities when local pressure falls sufficiently low.

Discharge coefficient: Ratio accounting for the difference between actual and ideal flow through a device.

Drift: Change in instrument indication with time under unchanged conditions.

Expanded uncertainty: Combined standard uncertainty multiplied by a stated coverage factor.

Hysteresis: Difference in indication at the same input during increasing and decreasing cycles.

Mass flow rate: Mass transported per unit time, ṁ = ρQ.

Precision: Closeness of repeated measurements to one another.

Random error: Unpredictable variation that produces scatter in repeated readings.

Resolution: Smallest change that an instrument can distinguish.

Rotameter: Variable-area flowmeter using the equilibrium position of a float.

Sensitivity: Change in output per unit change in input.

Systematic error: Repeatable bias caused by an identifiable influence.

Type A uncertainty: Uncertainty evaluated using statistical analysis of observations.

Type B uncertainty: Uncertainty evaluated from specifications, certificates, resolution, or judgement.

Uncertainty: Quantified doubt associated with a measurement result.

Vena contracta: Region downstream of an orifice where the jet reaches minimum area.

Volumetric flow rate: Volume transported per unit time, Q = dV/dt.

Weir: Open-channel structure that relates upstream head to discharge.

Review Questions

5 Short Answer Questions

  1. Distinguish gauge pressure from absolute pressure.
  2. What is the function of a discharge coefficient?
  3. Why must a rotameter normally be installed vertically?
  4. State one difference between Type A and Type B uncertainty.
  5. Why does an orifice meter usually have greater permanent pressure loss than a Venturi meter?

5 Long Answer Questions

  1. Explain the operating principle, assumptions, advantages, and limitations of a Pitot-static tube.
  2. Derive the ideal differential-pressure flow relation for a horizontal incompressible meter using continuity and Bernoulli’s equation, and explain why a discharge coefficient is required in practice.
  3. Compare Venturi meters, orifice meters, nozzles, and electromagnetic flowmeters for an industrial water system.
  4. Describe a complete calibration experiment using a weighing or volumetric tank as the reference method.
  5. Explain how systematic error, random error, resolution, repeatability, and uncertainty influence engineering decisions.

3 Analytical / Application Questions

  1. A pipeline operator observes that a differential-pressure flowmeter reads twice the actual flow after a transmitter configuration change. Diagnose the likely square-root extraction problem and propose verification tests.
  2. Design an experimental plan to determine whether a disagreement between an ultrasonic meter and a reference tank is caused by sensor calibration, air entrainment, or inadequate installation.
  3. A flow result depends on pipe diameter, pressure difference, density, and discharge coefficient. Identify the likely dominant uncertainty contributors and explain how you would reduce the combined uncertainty.

Multiple Choice Questions with Answers

Question 1

Which instrument measures local fluid velocity from the difference between stagnation and static pressure?

A. Pitot-static tube

B. Rotameter

C. Sharp-crested weir

D. Coriolis meter

Correct Answer: A. Pitot-static tube

Question 2

For a horizontal incompressible differential-pressure flowmeter, discharge is generally proportional to which quantity?

A. ∆p

B. 1/∆p

C. √∆p

D. (∆p)²

Correct Answer: C. √∆p

Question 3

A Venturi meter is generally preferred over an orifice meter when the primary requirement is:

A. Maximum permanent pressure loss

B. Low permanent pressure loss

C. Operation with an empty pipe

D. Measurement of nonconductive liquids using electrodes

Correct Answer: B. Low permanent pressure loss

Question 4

A rotameter operates primarily by measuring:

A. The frequency of vortex shedding

B. The float position in a variable-area tube

C. The magnetic voltage induced in a liquid

D. The transit time of an ultrasonic pulse

Correct Answer: B. The float position in a variable-area tube

Question 5

Which statement about Type A uncertainty is correct?

A. It is obtained only from a manufacturer’s specification

B. It is evaluated statistically from repeated observations

C. It is always equal to instrument resolution

D. It represents only calibration bias

Correct Answer: B. It is evaluated statistically from repeated observations

Question 6

A tank collects 0.240 m³ of water in 12.0 s. What is the reference volumetric flow rate?

A. 0.0020 m³/s

B. 0.0200 m³/s

C. 0.200 m³/s

D. 2.88 m³/s

Correct Answer: B. 0.0200 m³/s

Question 7

For independent input quantities, the usual root-sum-square uncertainty method combines contributions using:

A. The algebraic sum of signed errors only

B. The largest input uncertainty only

C. Sensitivity coefficients and squared standard uncertainties

D. The product of all measured values

Correct Answer: C. Sensitivity coefficients and squared standard uncertainties

Question 8

Which flowmeter generally requires the fluid to have sufficient electrical conductivity?

A. Electromagnetic flowmeter

B. Vortex meter

C. Mechanical rotameter

D. Sharp-crested weir

Correct Answer: A. Electromagnetic flowmeter

Question 9

If repeated readings are close together but consistently different from a reference value, the measurement is best described as:

A. Precise but biased

B. Inaccurate and random only

C. Neither measurable nor repeatable

D. Perfectly accurate

Correct Answer: A. Precise but biased

Question 10

For an ideal rectangular sharp-crested weir, discharge varies with upstream head approximately as:

A. H^(1/2)

B. H

C. H^(3/2)

D. H²

Correct Answer: C. H^(3/2)

Fluid Mechanics and Machinery
Chapter 5 of 15