Electrical Machines & Power Systems Laboratory

Chapter 5
Three-Phase Induction Machines

Bachelors Program in Electrical Engineering
Electrical Machines & Power Systems Laboratory   •   Bachelor

Three-Phase Induction Machines

Introduction and laboratory context

The three-phase induction machine is the most widely used industrial electromechanical energy converter. Its rugged squirrel-cage construction, low cost, high reliability, and limited maintenance requirements make it central to pumps, fans, compressors, conveyors, machine tools, and process plants. In the laboratory, the machine is studied not only as a motor but as a complete energy-conversion system whose electrical input, magnetic field, mechanical output, losses, speed, torque, and protection must be measured and interpreted.

This chapter develops the experimental methods used to conduct no-load, blocked-rotor, load, and speed-control tests. It also explains the equivalent circuit, slip, torque and power flow, efficiency, starting methods, braking, and indicators of electrical or mechanical faults. Numerical procedures are presented for a balanced, symmetrical machine. Actual laboratory results will depart from ideal predictions because of temperature, harmonics, instrument error, saturation, friction, windage, and supply imbalance.

Learning objectives

After completing this chapter, a student should be able to:

  1. Explain the production of a rotating magnetic field and the operation of a three-phase induction motor.
  2. Define synchronous speed, rotor speed, slip, rotor frequency, torque, and efficiency.
  3. Conduct and interpret no-load, blocked-rotor, and load tests safely.
  4. Determine approximate equivalent-circuit parameters from test data.
  5. Construct the machine power-flow diagram and calculate torque, losses, and efficiency.
  6. Compare direct-on-line, star–delta, autotransformer, soft-starter, and variable-frequency starting.
  7. Explain speed control and the principles of plugging, dynamic braking, and regenerative braking.
  8. Recognize fault indicators and distinguish electrical, mechanical, thermal, and supply-related abnormalities.

1. Operating principle

A balanced three-phase stator winding supplied at frequency f₁ produces a rotating magnetic field. For a stator having P poles, the synchronous mechanical speed is

ns = 120 f1 / P

where n_s is in revolutions per minute, f₁ is in hertz, and P is the number of poles. The corresponding angular speed is

ωs = 2π ns / 60

in radians per second. This field cuts the rotor conductors and induces rotor electromotive force. Because the rotor circuit is closed, rotor current flows and interacts with the air-gap field to produce electromagnetic torque.

The rotor cannot normally reach synchronous speed. If n_r = n_s, there would be no relative motion between the field and rotor conductors, no induced rotor frequency, and no torque. The slip is therefore

s = (ns − nr) / ns

where n_r is rotor speed in revolutions per minute. Slip is dimensionless and is often expressed as a percentage: s% = 100s. The rotor electrical frequency is

f2 = s f1

At standstill, s = 1 and f₂ = f₁. At normal operation, s is commonly a few percent in a well-designed motor. The rotor speed may also be written as n_r = (1 − s)n_s.

Torque production

The electromagnetic torque is proportional to the interaction of air-gap flux and rotor current. In the approximate per-phase equivalent circuit, the torque is

Te = (3 I2'2 R2') / (s ωs)

where I₂′ and R₂′ are rotor current and resistance referred to the stator, and ω_s is synchronous angular speed. This expression is applicable for a balanced sinusoidal supply and a consistent stator-referred equivalent circuit.

A more useful Thevenin form is

Te = [3 Vth² (R2'/s)] / [ωs ((Rth + R2'/s)² + (Xth + X2')²)]

where V_th, R_th, and X_th are the Thevenin voltage and impedance of the stator and magnetizing network as viewed from the rotor branch. Maximum torque occurs approximately when

R2'/s = √(Rth² + (Xth + X2')²)

For a low-resistance squirrel-cage motor, this condition is generally reached at a relatively high slip during starting or overload. Increasing rotor resistance in a wound-rotor motor increases the slip at maximum torque and improves starting torque, although it also increases rotor copper loss during operation.

2. Equivalent circuit and power flow

The per-phase approximate equivalent circuit contains the stator resistance R₁, stator leakage reactance X₁, a shunt magnetizing branch consisting of core-loss resistance R_c and magnetizing reactance X_m, and the rotor quantities referred to the stator, R₂′ and X₂′. The rotor branch is represented by R₂′/s + jX₂′. All quantities must be expressed on the same phase and voltage basis.

The rotor resistance term can be separated as

R2'/s = R2' + R2'(1 − s)/s

The first term represents rotor copper loss; the second represents converted mechanical power in the equivalent circuit. The principal power-flow relations are:

QuantityExpressionMeaning
Three-phase input powerP_in = √3 V_L I_L cosφPower from the supply
Stator copper lossP_Cu1 = 3 I₁²R₁Loss in stator winding
Core lossP_core ≈ 3V₁²/R_cHysteresis and eddy-current loss, approximately
Air-gap powerP_agPower transferred magnetically to rotor
Rotor copper lossP_Cu2 = sP_agElectrical loss in rotor conductors
Converted mechanical powerP_conv = (1 − s)P_agElectromagnetic mechanical power
Shaft outputP_out = P_conv − P_mechOutput after friction and windage

The torque relation linked to air-gap power is

Te = Pag / ωs = Pconv / ωr

where ω_r = 2πn_r/60. The equality follows because P_ag = T_eω_s and P_conv = T_eω_r. It is not correct to divide input power directly by rotor speed to obtain electromagnetic torque unless all intervening losses have been handled appropriately.

The efficiency is

η = Pout / Pin × 100%

Power factor is

cosφ = Pin / (√3 VL IL)

for a balanced three-phase system. Here V_L and I_L are line voltage and line current. In a star-connected load, phase voltage is V_L/√3 and phase current equals line current; in a delta-connected load, phase voltage equals line voltage and phase current is I_L/√3.

3. Laboratory equipment, preparation, and safety

A typical test bench contains a three-phase induction motor, a controllable supply or variac, a dynamometer or brake, a tachometer, wattmeters or a digital power analyzer, voltmeters, ammeters, a power-factor indication, protective fuses or circuit breakers, and emergency isolation. A motor-generator set may be used when regenerative operation or controlled loading is required.

Before energizing:

  • Confirm the nameplate voltage, connection, frequency, rated current, power, speed, and duty.
  • Inspect earth continuity, guards, couplings, terminals, and emergency-stop operation.
  • Set the supply to minimum and ensure the brake is released unless a specified test requires otherwise.
  • Check that the instrument ranges exceed the expected values.
  • Verify phase sequence and identify the correct star or delta connection.
  • Do not touch terminals while energized, and never block the rotor without a current-limited supply and a short test duration.

A blocked-rotor test is particularly hazardous because the motor draws a large current while producing no cooling airflow from rotation. The rotor must be mechanically secured, the applied voltage must be reduced, and the test should be stopped promptly when readings stabilize.

4. No-load test

Purpose

The no-load test estimates the magnetizing branch and rotational loss. The motor runs at rated frequency with no mechanical load. Voltage is varied, usually from a low value toward rated voltage, while line voltage, line current, input power, and speed are recorded.

Procedure

  1. Couple the motor only to a lightly loaded dynamometer, or leave the shaft uncoupled where permitted.
  2. Apply rated frequency and increase voltage gradually.
  3. At each stable voltage, record V_L, I_L, total three-phase input power P₀, and n₀.
  4. Avoid prolonged operation above rated voltage.
  5. Inspect whether current and power are balanced between phases.

At near-rated voltage, speed is close to synchronous speed, so slip and rotor copper loss are small. The input power consists mainly of stator copper loss, core loss, friction, and windage. If stator resistance is known, an approximate rotational-plus-core loss is

Ploss,0 ≈ P0 − 3 I0²R1

This estimate assumes balanced current and neglects the small rotor copper loss and any significant variation of R₁ with temperature. If a constant rotational loss is required, measurements at several voltages can help separate voltage-dependent core loss from nearly speed-dependent mechanical loss, but the separation is approximate.

For a balanced star-connected motor, the per-phase no-load impedance magnitude is Z₀ = V_phase/I₀. The no-load power factor is

cosφ0 = P0 / (√3 VL IL)

The active and reactive components of phase current may be estimated as I_w = I₀cosφ₀ and I_m = I₀sinφ₀. Approximate shunt parameters are R_c = V_phase/I_w and X_m = V_phase/I_m. These estimates are most reliable when the voltage basis and the treatment of stator impedance are clearly stated.

5. Blocked-rotor test

Purpose

The blocked-rotor test determines the approximate series impedance and rotor-referred resistance. The rotor is locked, so n_r = 0 and s = 1. A reduced-frequency or reduced-voltage supply is used to limit current to a safe value.

Procedure

  1. Secure the rotor and verify the mechanical locking arrangement.
  2. Set the applied voltage to zero before energizing.
  3. Increase voltage until the specified current, normally rated current, is reached.
  4. Record line voltage V_L, line current I_L, input power P_br, and the applied frequency.
  5. De-energize immediately after stable readings are obtained.

At rated frequency, the approximate per-phase blocked-rotor impedance is

Zbr = Vphase / Iphase

The equivalent resistance is

Rbr = Pbr / (3 Iphase²)

and the equivalent leakage reactance is

Xbr = √(Zbr² − Rbr²)

For a star connection, V_phase = V_L/√3 and I_phase = I_L. For a delta connection, V_phase = V_L and I_phase = I_L/√3. The resulting approximate relations are R_br ≈ R₁ + R₂′ and X_br ≈ X₁ + X₂′. If the test is performed at reduced frequency f_test, leakage reactance should be referred approximately to the rated frequency f₁ by

Xbr,rated ≈ Xbr,test (f1 / ftest)

provided the magnetic state and frequency-dependent effects permit this approximation. Resistance must be corrected for winding temperature when accurate parameters are required.

Worked example: blocked-rotor parameters

A delta-connected motor is tested at 50 Hz. The readings are V_L = 80 V, I_L = 12 A, and P_br = 900 W. The phase voltage is 80 V and phase current is 12/√3 = 6.93 A. Therefore,

Z_br = 80/6.93 = 11.55 Ω,

R_br = 900/(3 × 6.93²) = 6.25 Ω,

X_br = √(11.55² − 6.25²) = 9.71 Ω.

Thus the approximate stator-referred series parameters are R₁ + R₂′ = 6.25 Ω and X₁ + X₂′ = 9.71 Ω per phase. The calculation is valid on the delta phase basis used in the test.

6. Load test and performance determination

The load test measures the actual relationship between torque, speed, current, power factor, efficiency, and slip. With the motor operating at rated voltage and frequency, mechanical load is increased in steps. At each point, record line voltage, line current, input power, speed, and torque. Temperature should be monitored because winding resistance and losses rise with temperature.

Mechanical output power is

Pout = TL ωr = 2π nr TL / 60

where T_L is shaft torque in newton-metres and n_r is speed in revolutions per minute. The result is in watts. If torque is measured by a brake using a force F at radius r, then T_L = Fr, provided F is the tangential force in newtons and r is in metres.

Slip at each load point is calculated from the measured speed:

s = (ns − nr)/ns

Input power is measured by the two-wattmeter method for a three-wire balanced or unbalanced system. For total active power,

Pin = W1 + W2

For a balanced load, power factor can also be found from

tanφ = √3 (W1 − W2)/(W1 + W2)

The expression is sensitive to wattmeter sign conventions and is especially important when the power factor is below 0.5, where one wattmeter may read negative. Digital instruments may display signed power directly.

Worked example: speed, torque, and efficiency

A four-pole, 50 Hz motor operates at 1,440 r/min while delivering 18 N·m. The measured three-phase input power is 15.0 kW. Synchronous speed is

n_s = 120 × 50/4 = 1,500 r/min.

Slip is s = (1,500 − 1,440)/1,500 = 0.040, or 4.0%. Rotor frequency is f₂ = 0.040 × 50 = 2.0 Hz. Shaft angular speed is ω_r = 2π × 1,440/60 = 150.8 rad/s. Hence,

P_out = 18 × 150.8 = 2,714 W,

η = 2,714/15,000 × 100% = 18.1%.

The low calculated efficiency is not typical of a normally loaded industrial motor; it indicates that either the stated torque is a brake torque at a very light or abnormal operating condition, the input measurement includes an error, or the example represents a deliberately inefficient test condition. This illustrates why measured quantities must be cross-checked against the nameplate rating and expected performance.

The electromagnetic torque can be estimated from air-gap power if the power-flow losses are known. At light load, the friction and windage loss can be a substantial fraction of the small output power, so efficiency is often poor.

7. Starting methods

At starting, s = 1 and the motor draws a high current because the rotor frequency equals supply frequency and the effective impedance is relatively low. Starting current can cause voltage drop, thermal stress, mechanical shock, and nuisance tripping.

Direct-on-line (DOL) starting connects the motor directly to the rated supply. It provides high starting torque and simple control, but the current may be five to eight times rated current, depending on motor design. It is suitable when the supply is stiff and the motor is small enough for the installation rules.

Star–delta starting initially connects a delta-rated motor in star. Each winding receives 1/√3 of the delta voltage. Neglecting saturation and other changes, starting line current and torque are approximately one-third of their delta-starting values. The method reduces starting stress but provides lower starting torque and can produce a transient at changeover.

Autotransformer starting applies a selected reduced voltage and can provide better torque per line current than star–delta, but it requires a more complex starter.

Primary-resistance or reactor starting reduces voltage by inserting impedance. It is simple but wastes power and reduces torque approximately with the square of voltage.

Soft starters use controlled semiconductor switches to ramp voltage and reduce current and mechanical shock. They do not provide the same broad speed control as a variable-frequency drive.

Variable-frequency drives (VFDs) control frequency and voltage. Below base speed, approximately constant V/f maintains flux; above base speed, voltage is limited and the motor enters field-weakening operation. A VFD can provide controlled acceleration, current limiting, energy savings in variable-torque loads, and regenerative or braking functions when properly equipped.

8. Speed control

The speed relation n_r = (1 − s)120f₁/P shows three fundamental control variables: frequency, pole number, and slip.

  • Frequency control changes synchronous speed and is the preferred method for high-performance squirrel-cage motors.
  • Pole-changing motors provide discrete speeds using specially arranged windings.
  • Stator-voltage control changes torque and slip, and is effective mainly for fan and pump loads; it causes poor power factor and increased heating at low speed.
  • Rotor-resistance control applies to wound-rotor motors. It increases slip and provides useful starting or low-speed torque, but the added resistance dissipates power.
  • Slip-power recovery systems return rotor slip energy to the supply or a converter and can improve efficiency in suitable wound-rotor applications.

A constant V/f strategy is not exact at very low frequencies because the stator resistance voltage drop becomes significant. Low-speed drives therefore use voltage boost, current regulation, vector control, or direct torque control. These advanced controls are valuable where rapid torque response, positioning, or energy optimization is required.

9. Braking

Coasting simply removes supply power; the rotor decelerates through mechanical and load losses.

Plugging reverses the phase sequence while the motor is rotating. The developed torque opposes rotation, but current and heating are high. Supply must be disconnected near zero speed to prevent reverse acceleration.

DC injection braking applies direct current to the stator after AC disconnection. A stationary magnetic field induces braking currents in the rotating rotor. It is effective for stopping but does not return energy to the supply and can overheat the motor.

Dynamic braking uses a converter or resistor to dissipate kinetic or regenerated energy. In a VFD system, a braking resistor may be connected to the DC link.

Regenerative braking occurs when the rotor is driven above synchronous speed in the direction of rotation, or when a controlled drive commands negative slip. Mechanical energy is converted to electrical energy and returned to the supply or a common DC bus. Regeneration requires a suitable converter and protection against excessive DC-link voltage.

10. Fault indicators and diagnostic interpretation

A single measurement rarely proves a fault. Diagnosis should combine electrical, mechanical, thermal, acoustic, and trend data.

ObservationPossible causesConfirmatory checks
High current at no loadLow voltage imbalance, wrong connection, damaged bearings, core saturationMeasure phase voltages, connection, vibration, and current balance
Excessive slip under loadOverload, low voltage, high rotor resistance, broken rotor barsTorque-speed test, thermal scan, current spectrum
Unequal phase currentsSupply imbalance, winding fault, loose terminalPhase-to-phase resistance, insulation test, supply quality
Humming and vibrationMisalignment, bearing wear, bent shaft, magnetic asymmetryVibration spectrum, alignment and bearing inspection
High temperatureOverload, blocked ventilation, frequent starts, harmonicsThermal imaging, cooling inspection, load and drive settings
Negative or implausible wattmeter readingsIncorrect connections, low power factor, reversed polarityVerify wattmeter wiring and sign convention
Speed oscillationUnstable drive control, load variation, mechanical loosenessExamine drive waveform, encoder, coupling, and load

Common tests include insulation resistance, winding resistance, phase-balance measurement, vibration analysis, thermal imaging, and motor-current signature analysis. These tests must be interpreted within manufacturer limits and applicable electrical safety standards. Insulation testing should be performed only with the equipment isolated and with sensitive electronic drives disconnected where required.

11. Applied case: illustrative pump-motor investigation

Background

An illustrative water-treatment plant reports that a 30 kW, 400 V, 50 Hz induction motor driving a centrifugal pump trips intermittently during morning startup. Operators also observe a brief voltage dip and increased vibration.

Problem

The plant must determine whether the cause is excessive starting current, a mechanical pump problem, supply imbalance, or an incorrect starter setting.

Analysis

A no-load inspection shows that the motor reaches nearly synchronous speed normally. A load test with the pump isolated gives balanced currents and acceptable vibration. When the pump is coupled, the motor takes longer to accelerate and the current remains high. A blocked-rotor test is not repeated on the installed machine because it would impose unnecessary stress; previously determined laboratory parameters are used instead. Measurements at the supply show a small voltage imbalance, while the pump suction filter is partially blocked.

Approach and solution

The filter is cleaned and the pump is checked for alignment. The starter is changed from DOL to a controlled soft-start sequence after confirming that the pump can develop adequate accelerating torque. Voltage and current are recorded on all phases, and a thermal limit is set in the protection relay. If future operation requires speed variation, a properly rated VFD with bypass and harmonic considerations would be evaluated rather than treating the soft starter as a speed controller.

Outcome

Acceleration time decreases, the voltage dip is reduced, and vibration returns to an acceptable trend. The remaining voltage imbalance is referred to the distribution engineer because even a small negative-sequence voltage can produce a disproportionately larger negative-sequence current and additional rotor heating.

Learning points

The case demonstrates that a motor trip is not automatically a motor fault. Electrical measurements must be correlated with the driven load, starting method, supply quality, protection settings, and mechanical condition. It also illustrates the distinction between reduced-voltage starting and true frequency-based speed control.

12. Limitations, best practices, and contemporary developments

Equivalent-circuit parameters obtained from simplified tests are approximate. The no-load test is affected by core saturation and rotational losses; the blocked-rotor test is affected by skin effect, temperature, and frequency; and the load test is affected by dynamometer calibration and transient operation. Instrument transformers, wattmeter phase errors, non-sinusoidal VFD waveforms, and unbalanced supplies can make classical formulas inaccurate.

Best practice is to record instrument ranges and uncertainties, identify whether values are line or phase quantities, correct resistance to the measured winding temperature when appropriate, repeat measurements, and compare calculated input power with the wattmeter total. Every result should be checked against physical plausibility: current should not be reported without a voltage basis, efficiency should not exceed 100%, and a calculated speed should be below synchronous speed in motoring operation.

Modern induction-motor laboratories increasingly use power analyzers, digital tachometers, thermal cameras, vibration sensors, and data acquisition systems. AI-based condition monitoring can classify abnormal current or vibration patterns, but it does not replace electrical isolation, engineering judgment, or validated protection settings. Training data may be incomplete, and false alarms or missed faults can have safety consequences. The responsible approach is to use analytics as decision support, preserve traceable measurements, and retain human authorization for protection and maintenance actions.

Chapter Summary

A three-phase induction motor develops torque because a rotating stator field induces rotor currents. Synchronous speed depends on frequency and pole number, while slip measures the relative speed required for induction. The no-load test estimates magnetizing and rotational behavior; the blocked-rotor test estimates series resistance and leakage reactance; and the load test establishes torque, speed, current, power factor, output, slip, and efficiency.

The power-flow model distinguishes stator copper and core losses, air-gap power, rotor copper loss, converted mechanical power, mechanical loss, and shaft output. Starting methods trade current, torque, cost, and complexity. Frequency control is the principal modern speed-control method, while plugging, DC injection, dynamic braking, and regeneration provide different stopping or energy-management capabilities. Reliable diagnosis combines test results with supply, mechanical, thermal, and protection information. Safe isolation, correct phase/line conversions, careful instrument use, and critical comparison with nameplate data are essential laboratory practices.

Key Terms

Synchronous speed: Speed of the rotating stator magnetic field.

Slip: Difference between synchronous speed and rotor speed divided by synchronous speed.

Rotor frequency: Electrical frequency induced in the rotor, equal to slip times supply frequency.

Air-gap power: Power transferred electromagnetically from stator to rotor.

Rotor copper loss: Electrical loss in rotor conductors, equal approximately to sP_ag.

Converted mechanical power: Air-gap power converted electromagnetically into mechanical form.

No-load test: Test with negligible external mechanical load used to study excitation and rotational losses.

Blocked-rotor test: Test with the rotor locked and reduced voltage applied to determine series parameters.

Load test: Test in which shaft torque is varied and operating performance is measured.

Equivalent circuit: Per-phase electrical model representing stator, magnetizing, and rotor behavior.

Thevenin equivalent: Reduced source representation used to analyze rotor current and torque.

Direct-on-line starting: Starting method that applies rated supply voltage directly to the motor.

Star–delta starting: Reduced-voltage starting method using an initial star connection.

Soft starter: Semiconductor controller that ramps applied voltage during starting and stopping.

Variable-frequency drive: Converter that controls motor frequency and voltage for speed and torque control.

Plugging: Braking by reversing the rotating-field direction while the rotor is moving.

Dynamic braking: Braking that converts energy to heat in a resistor or braking circuit.

Regenerative braking: Braking in which mechanical energy is returned to an electrical supply or DC bus.

Negative-sequence current: Current component associated with a reverse-rotating field and potentially severe rotor heating.

Power factor: Ratio of active three-phase power to apparent three-phase power.

Review Questions

Short Answer Questions

  1. Why can an induction motor not produce steady torque at synchronous speed?
  2. Define slip and rotor frequency.
  3. What is the purpose of the blocked-rotor test?
  4. State two safety precautions for a blocked-rotor test.
  5. Distinguish a soft starter from a variable-frequency drive.

Long Answer Questions

  1. Explain the construction and operating principle of a squirrel-cage induction motor, including the role of slip.
  2. Describe the no-load, blocked-rotor, and load tests, stating the measurements and principal calculations for each.
  3. Develop the induction-motor power-flow sequence from electrical input to shaft output.
  4. Compare DOL, star–delta, autotransformer, soft-start, and VFD starting methods.
  5. Explain plugging, DC injection, dynamic, and regenerative braking, including their principal limitations.

Analytical / Application Questions

  1. A four-pole, 50 Hz motor runs at 1,455 r/min. Calculate synchronous speed, slip, and rotor frequency.
  2. A balanced motor absorbs 12 kW at 400 V and 22 A. Calculate its power factor using the three-phase power relation.
  3. A motor exhibits unequal phase currents, increased vibration, and overheating under normal load. Propose a logically ordered diagnostic investigation and justify each measurement.

Multiple Choice Questions with Answers

Question 1

A four-pole induction motor is supplied at 50 Hz. What is its synchronous speed?

A. 750 r/min

B. 1,000 r/min

C. 1,500 r/min

D. 3,000 r/min

Correct Answer: C. 1,500 r/min

Question 2

A motor has synchronous speed 1,500 r/min and rotor speed 1,440 r/min. What is the slip?

A. 2%

B. 4%

C. 6%

D. 10%

Correct Answer: B. 4%

Question 3

At a slip of 0.04 and supply frequency of 50 Hz, the rotor frequency is:

A. 0.2 Hz

B. 2 Hz

C. 12.5 Hz

D. 46 Hz

Correct Answer: B. 2 Hz

Question 4

In a blocked-rotor test, the slip is:

A. 0

B. Less than 0.01

C. 0.5

D. 1

Correct Answer: D. 1

Question 5

For a balanced three-phase motor, total input power is calculated from line quantities as:

A. V_L I_L cosφ

B. 3V_L I_L cosφ

C. √3 V_L I_L cosφ

D. V_L I_L sinφ

Correct Answer: C. √3 V_L I_L cosφ

Question 6

In an induction motor, rotor copper loss is approximately:

A. (1 − s)P_ag

B. sP_ag

C. P_ag/s

D. P_ag + s

Correct Answer: B. sP_ag

Question 7

The principal purpose of a variable-frequency drive is to:

A. Measure insulation resistance

B. Control motor speed by controlling supply frequency

C. Increase pole number mechanically

D. Eliminate all motor losses

Correct Answer: B. Control motor speed by controlling supply frequency

Question 8

If a delta-connected motor is changed to star during starting at the same line voltage, the winding phase voltage becomes:

A. Three times larger

B. Twice larger

C. 1/√3 of the delta value

D. Unchanged

Correct Answer: C. 1/√3 of the delta value

Question 9

Which braking method can return mechanical energy to the electrical system?

A. Coasting

B. DC injection braking

C. Regenerative braking

D. Mechanical friction braking only

Correct Answer: C. Regenerative braking

Question 10

A negative-sequence supply component is particularly concerning because it can cause:

A. Rotor heating and additional losses

B. Zero rotor current at all loads

C. Infinite synchronous speed

D. Removal of stator copper loss

Correct Answer: A. Rotor heating and additional losses

Electrical Machines & Power Systems Laboratory
Chapter 5 of 15