Electrical Machines and Drives

Chapter 2
Machine Construction, Materials, Windings, and Ratings

Bachelor Program in Mechatronics Engineering
Electrical Machines and Drives   •   Bachelor

Machine Construction, Materials, Windings, and Ratings

Introduction

Electrical machines convert energy between electrical and mechanical forms through magnetic fields. Their performance, reliability, efficiency, and cost depend not only on electromagnetic design but also on constructional materials, winding arrangement, thermal management, insulation, mechanical strength, and standardized ratings. A mechatronics engineer must therefore be able to interpret a machine nameplate, select a suitable motor for a duty cycle, identify major components, and understand why a machine fails in service.

This chapter considers the common constructional features of transformers, rotating machines, induction motors, synchronous machines, and direct-current machines. The emphasis is on principles applicable to industrial motors and generators, while recognizing that detailed construction varies with machine type and power rating.

Learning objectives

After studying this chapter, the reader should be able to:

  1. Identify the principal stationary and rotating parts of electrical machines.
  2. Explain the functions of electrical steel, conductors, insulation, bearings, and structural materials.
  3. Distinguish concentrated, distributed, single-layer, double-layer, lap, wave, and fractional-slot windings.
  4. Explain cooling methods, insulation classes, ingress-protection codes, and duty types.
  5. Interpret important nameplate quantities and international rating conventions.
  6. Select and justify a motor for a practical mechatronic application.
  7. Diagnose how construction, thermal loading, and duty affect machine life.

1. Principal machine components

A rotating electrical machine normally consists of a stator, rotor, air gap, bearings, frame, end shields, shaft, cooling system, terminal box, and protective enclosure. A transformer has no rotating parts but uses a magnetic core, windings, insulation system, tank or enclosure, and cooling arrangement.

Stator and rotor

The stator is the stationary magnetic and electrical assembly. In an alternating-current motor it commonly contains a laminated ferromagnetic core with slots carrying the stator winding. The rotor rotates inside the stator bore and is mounted on a shaft. Depending on the machine, it may contain a squirrel-cage winding, permanent magnets, a wound field winding, or a commutator winding.

The air gap is the clearance between stator and rotor. It must be sufficiently small to reduce magnetizing current, but large enough to accommodate manufacturing tolerances, thermal expansion, vibration, and possible shaft deflection. A small, uniform air gap improves magnetic utilization; an excessively small gap increases the risk of mechanical contact.

The frame supports the stator and transfers electromagnetic and mechanical forces to the foundation. End shields locate the bearings and maintain rotor alignment. The shaft transmits torque to the load. Bearings support radial and, where necessary, axial forces. Rolling-element bearings are common in small and medium machines; sleeve bearings are often used in large machines.

Core, slots, and teeth

The magnetic core provides a low-reluctance path for flux. Slots accommodate conductors, while teeth carry flux between slots. Slot geometry affects leakage reactance, tooth saturation, mechanical strength, acoustic noise, and manufacturability. Open slots simplify insertion of formed coils; semi-closed or closed slots can reduce pulsating torque and noise but complicate winding manufacture.

The rotor may be smooth or salient. A salient-pole rotor has projecting poles and is common in low-speed synchronous machines and many hydroelectric generators. A cylindrical rotor has a smooth surface and is suitable for high-speed turbo-generators. Induction-motor rotors are commonly squirrel-cage types, consisting of conductive bars joined by end rings, or wound rotors with insulated three-phase windings.

Transformer construction

A transformer may use a core-type or shell-type arrangement. In a core-type transformer, windings surround portions of the core; in a shell-type transformer, the core substantially surrounds the windings. The core is assembled from thin laminations, and windings are separated by insulation designed for electrical, thermal, and mechanical stresses. Distribution transformers may use mineral oil, ester fluid, or air as an insulating and cooling medium.

2. Materials used in electrical machines

Material selection is a compromise among magnetic performance, electrical conductivity, insulation strength, thermal endurance, mechanical strength, manufacturability, cost, and environmental compatibility.

Electrical steels

Magnetic cores are usually made from silicon steel, also called electrical steel. It has higher electrical resistivity and lower hysteresis loss than ordinary carbon steel. The core is laminated to interrupt circulating eddy-current paths.

For sinusoidal flux, a simplified representation of specific core loss is:

pc ≈ kh f Bmn + ke f² Bm²

Here, pc is specific core loss in W/kg, f is frequency in hertz, Bm is peak flux density in tesla, kh and ke are material-dependent coefficients, and n is commonly between approximately 1.6 and 2.2. This is an empirical model, not a universal exact law. It applies as an engineering approximation over the frequency and flux-density range for which the coefficients were obtained.

Grain-oriented electrical steel is used mainly where flux follows a preferred direction, especially transformer cores. Non-oriented electrical steel is used in rotating machines because flux direction changes around the core. Thin laminations reduce eddy-current loss but increase manufacturing cost and may require careful insulation between sheets. Excessive punching stress, burrs, or damaged interlaminar coating can increase losses.

Conductors

Copper and aluminium are the principal winding conductors. Copper has high conductivity, good mechanical strength, and excellent solderability, but is relatively expensive and dense. Aluminium is lighter and less costly, but requires larger cross-sectional area for the same current and careful joint design because its oxide layer is electrically resistive.

For a conductor carrying current I, the approximate resistive loss is:

Pcu = I²R

where Pcu is loss in watts, I is current in amperes, and R is resistance in ohms at the operating temperature. Since conductor resistance increases with temperature, thermal design cannot rely only on the room-temperature resistance.

The current density is:

J = I/Ac

where J is current density in A/m² and Ac is conductor cross-sectional area in m². Permissible current density depends on cooling, insulation system, duty, frequency, conductor geometry, and allowable temperature rise. High-frequency machines may use stranded or transposed conductors to reduce skin and proximity effects.

Insulation systems

Insulation separates conductors from one another and from the core or frame. It must withstand operating voltage, transient overvoltages, vibration, thermal cycling, moisture, contamination, and partial discharge where applicable. Common materials include enamelled wire coatings, mica, glass, polyester, polyimide, epoxy, and aramid products.

Insulation classes specify thermal capability. Common IEC thermal classes include:

ClassReference maximum insulation-system temperature
A105 °C
E120 °C
B130 °C
F155 °C
H180 °C

These values describe the thermal class of the insulation system, not necessarily the permitted external surface temperature or a guaranteed winding temperature. Actual allowable temperature rise depends on ambient temperature, altitude, measurement method, service factor, and applicable standard.

A useful engineering approximation for insulation ageing is the thermal life rule: for many insulation systems, a sustained increase of roughly 10 K in hot-spot temperature can approximately halve life over a limited operating range. This is a rule of thumb, not a universal law; moisture, vibration, voltage stress, contamination, and partial discharge may dominate ageing.

Structural and auxiliary materials

Frames and end shields are commonly cast iron, cast aluminium, or fabricated steel. Permanent magnets may use ferrite, neodymium-iron-boron, or samarium-cobalt. NdFeB magnets provide high energy density but may suffer corrosion or irreversible demagnetization at excessive temperature. Shafts require fatigue-resistant steel, and rotor cages may use aluminium or copper. Fans, cable glands, seals, varnishes, and bearing lubricants must be compatible with the thermal and environmental conditions.

3. Winding arrangements

A winding is a set of conductors arranged to create a desired magnetomotive-force distribution or to receive induced emf. Winding choice affects voltage, current, torque ripple, harmonics, insulation stress, manufacturability, and repairability.

Concentrated and distributed windings

In a concentrated winding, conductors associated with a phase or pole are placed in a limited number of slots. Such windings are common in some permanent-magnet machines and can simplify manufacturing, but they may produce greater space harmonics and torque ripple.

In a distributed winding, coils belonging to a phase are spread over several slots. Distribution generally produces a more nearly sinusoidal magnetomotive force and reduces selected harmonics, although it increases end connections and manufacturing complexity.

For a balanced three-phase sinusoidal winding, the ideal rotating magnetic field has synchronous speed:

ns = 120f/P

where ns is synchronous speed in revolutions per minute, f is supply frequency in hertz, and P is the number of poles. The formula assumes a balanced sinusoidal supply and defines the speed of the fundamental rotating field. For an induction motor, the rotor runs below synchronous speed in motoring operation.

Single-layer and double-layer windings

In a single-layer winding, each slot contains one coil side. In a double-layer winding, two coil sides occupy each slot, usually in different layers. Double-layer windings provide flexibility in selecting coil pitch and phase-belt arrangement and are widely used in AC machines.

A full-pitch coil spans approximately one pole pitch. A short-pitched coil spans fewer slots than a full-pitch coil. Short pitching can reduce particular harmonics and shorten end connections, but it slightly reduces the fundamental induced emf. The winding factor is often represented as:

kw = kp kd

where kw is winding factor, kp is pitch factor, and kd is distribution factor. Both factors are dimensionless and generally not greater than unity in magnitude. Exact values depend on slotting, coil pitch, phase number, and harmonic order.

Lap and wave windings in DC machines

A simplex lap winding has parallel paths approximately equal to the number of poles, making it suitable for low-voltage, high-current machines. A simplex wave winding has approximately two parallel paths and is suitable for higher-voltage, lower-current machines. Equalizer connections may be required in lap windings to reduce circulating currents caused by unequal induced emfs.

Fractional-slot and special windings

Fractional-slot windings use a fractional number of slots per pole per phase. They are common in permanent-magnet and high-performance machines because they can reduce cogging torque, copper end-turn length, or manufacturing complexity. However, they can introduce subharmonics, unbalanced magnetic forces, and additional acoustic noise if poorly designed.

4. Cooling and thermal limits

Nearly all machine losses become heat. The principal losses are stator and rotor copper losses, core losses, mechanical losses from friction and windage, and additional stray-load losses. Temperature rise is governed by the balance between generated heat and heat transferred to the surroundings.

The thermal model is often approximated by a resistance-capacitance network. At steady state:

∆T = Ploss R_θ

where ∆T is temperature rise in kelvin, Ploss is total loss in watts, and R_θ is thermal resistance in K/W. The approximation assumes a linear thermal path and steady conditions. Real machines have multiple nodes, temperature-dependent properties, and transient thermal behaviour.

Cooling methods include:

  • natural air cooling, in which heat is removed by convection and radiation;
  • totally enclosed fan-cooled construction, in which an external fan moves air over the frame;
  • open ventilated construction, in which internal air exchanges with the environment;
  • forced ventilation, using an independent blower;
  • liquid cooling, used where power density is high or acoustic constraints are severe;
  • hydrogen or other specialized cooling in large generators.

Cooling performance decreases with altitude because air density is lower. Blocked ventilation, excessive dust, high ambient temperature, misaligned bearings, and operation at low speed with an inverter-controlled motor can all cause overheating. A motor driven below base speed by a variable-frequency drive may require an independent fan because its shaft-mounted fan produces less airflow.

5. Duty cycles and machine ratings

A motor rating must reflect how it is actually used. A motor that is adequate for continuous operation may be unsuitable for repeated acceleration, braking, or short high-power periods.

IEC duty types include:

DutyMeaningTypical application
S1Continuous duty at constant load until thermal equilibriumPump or fan
S2Short-time duty followed by sufficient rest for coolingActuator positioning
S3Intermittent periodic duty with starting effects negligibleHoist auxiliary drive
S4Intermittent duty including significant startingConveyor with frequent starts
S5Intermittent duty including starting and electrical brakingRapid positioning system
S6Continuous periodic duty with load and no-load periodsCompressor with unloaded intervals
S7Continuous periodic duty with starting and braking, without restServo-like cyclic drive
S8Continuous periodic duty with speed/load changesMulti-speed production machine
S9Non-periodic duty with significant overloads and speed variationTraction drive
S10Duty with discrete constant loads and specified thermal effectsVariable-process drive

For a cyclic load with approximately constant speed, an equivalent heating current may be estimated by:

Ieq = √[(Σ Ii² ti)/(Σ ti)]

where Ii is the current during interval i, ti is its duration, and the summation covers one representative cycle. This method assumes that copper loss is proportional to current squared, resistance is approximately constant, and thermal transients are not so severe that a simple average becomes invalid. Acceleration, braking losses, core loss variation, and cooling changes may require a more detailed thermal model.

Torque, power, and speed

Mechanical output power is:

Pout = Tω = 2πnT/60

where Pout is power in watts, T is torque in newton-metres, ω is angular speed in radians per second, and n is speed in revolutions per minute. This equation applies to rotational mechanical power. It shows why a low-speed drive requires more torque than a high-speed drive for the same power.

6. Nameplate quantities and international conventions

A motor nameplate communicates the conditions under which the manufacturer guarantees rated performance. Common entries include rated output power, voltage, current, frequency, speed, phase number, connection, power factor, efficiency, duty, insulation class, ambient temperature, altitude, enclosure, protection, bearing information, and standards compliance.

Voltage, current, and connection

A three-phase motor may be marked 230/400 V Δ/Y. At a 400 V line-to-line supply it is connected in star; at a 230 V line-to-line supply it is connected in delta. Incorrect connection can cause excessive phase voltage and severe current or torque problems.

For a balanced three-phase load, apparent power is:

S = √3 VL IL

where S is apparent power in volt-amperes, VL is line-to-line RMS voltage, and IL is line current. Real input power is:

Pin = √3 VL IL cosφ

where cosφ is power factor. These expressions assume a balanced sinusoidal three-phase system. With significant harmonics, true RMS quantities and distortion power must be considered.

Motor efficiency is:

η = Pout/Pin

where η is dimensionless efficiency. The power factor is not efficiency: power factor describes how effectively current produces real power, whereas efficiency compares mechanical output with electrical input.

Speed and slip

For an induction motor:

s = (ns − nr)/ns

where s is slip as a per-unit quantity, ns is synchronous speed, and nr is rotor speed. Slip is positive in motoring operation. It is often expressed as a percentage by multiplying by 100. A four-pole, 50 Hz motor has ns = 120×50/4 = 1500 r/min; if its rotor speed is 1455 r/min, its slip is (1500−1455)/1500 = 0.03, or 3%.

Protection and enclosure codes

The IEC 60529 IP code describes protection provided by an enclosure. The first numeral concerns solid objects and access; the second concerns water. For example, IP55 indicates dust-protected construction and protection against water jets. IP ratings do not by themselves specify explosion protection, corrosion resistance, mechanical impact strength, or suitability for every hazardous location.

NEMA enclosure designations, such as Open Drip-Proof and Totally Enclosed Fan-Cooled, are widely used in North America. IEC IP codes and NEMA descriptions are related but are not automatically interchangeable. Selection should follow the governing installation standard and manufacturer documentation.

Insulation, temperature, and service factor

A nameplate may state insulation class F, temperature rise, ambient temperature, or a service factor. A service factor is not a universal permission to operate continuously above rated load; its meaning depends on the relevant standard and operating conditions. Inverter-fed motors may require information about permissible voltage rise time, peak voltage, bearing currents, and speed range.

7. Protection, safety, and installation practice

Electrical machines require protection against overload, short circuit, earth fault, phase loss, undervoltage, overspeed, excessive temperature, and loss of cooling. Protective devices must coordinate with starting current and permissible thermal withstand. A circuit breaker protects conductors and fault conditions; an overload relay protects against sustained overcurrent; a thermal sensor can detect winding hot spots.

Earthing of the frame is essential. Guards must prevent contact with rotating parts, and lockout/tagout procedures must be used before maintenance. Capacitors, variable-frequency drives, and regenerative loads can retain hazardous energy after disconnection. In explosive atmospheres, equipment must have the correct certified protection concept; an ordinary IP rating is insufficient.

Environmental selection also involves noise, vibration, electromagnetic compatibility, bearing-current mitigation, chemical exposure, condensation, and washdown requirements. Engineers should use current editions of applicable IEC, ISO, NEMA, and local electrical-installation standards rather than relying on informal equivalence tables.

8. Applied case: selecting a motor for a conveyor

Background

An automated packaging line requires a motor-driven conveyor. The conveyor operates for 10 minutes at 1.5 kW mechanical load, stops for 2 minutes, and then accelerates to speed in 4 seconds. The cycle repeats continuously. The environment is dusty but not explosive, with an ambient temperature of 40 °C. The drive uses a variable-frequency inverter.

Problem

A continuously rated 1.5 kW motor is proposed. The engineer must decide whether its rating, cooling, enclosure, and protection are appropriate.

Analysis

The load period is much longer than the acceleration period, so the motor is primarily thermally loaded during conveyance. However, frequent starting produces additional current and mechanical stress. If the motor is stopped rather than unloaded, the duty resembles S4 rather than simple S1. The inverter allows controlled acceleration and may reduce mechanical shock, but it does not eliminate copper loss during high-current acceleration.

At low conveyor speed, a shaft-mounted fan may provide inadequate cooling. An independently ventilated motor or a manufacturer-approved constant-torque inverter-duty motor is therefore preferable. Because the environment is dusty, an enclosed construction with an appropriate IP rating is needed. If washdown is present, seals and corrosion resistance must also be specified.

Assume a representative cycle current of 8 A for 600 s, 2 A for 120 s while stopped or unloaded, and 18 A for 4 s during acceleration. The approximate equivalent current is:

Ieq = √[(8²×600 + 2²×120 + 18²×4)/(724)] ≈ 7.7 A

This value is only a first screening calculation. The manufacturer’s thermal model must also consider low-speed cooling, acceleration torque, inverter waveform, overload duration, and allowable temperature rise.

Approach and outcome

A suitable selection would specify an inverter-rated motor with continuous torque capability over the required speed range, independent ventilation if necessary, an enclosure appropriate to dust, class F or better insulation as required by the drive system, overload protection, and a brake or controlled stopping method if the conveyor must stop rapidly. The motor should be checked against starting torque, belt inertia, gearbox ratio, service factor interpretation, and the drive manufacturer’s output-voltage limits.

Learning points

The nominal kilowatt rating alone does not determine suitability. Duty type, thermal cycle, cooling at low speed, environment, starting frequency, and drive compatibility are equally important. Nameplate interpretation is therefore a system-engineering task rather than a simple power comparison.

9. Contemporary developments and limitations

Modern machines increasingly use permanent magnets, hairpin windings, additive-manufactured cooling channels, high-frequency inverters, and embedded temperature and vibration sensors. Digital monitoring can estimate bearing wear, insulation degradation, eccentricity, and unbalance from electrical and mechanical measurements. Machine-learning models may assist predictive maintenance, but they require representative data, validated failure labels, cybersecurity controls, and human engineering oversight. A prediction is not a substitute for a safe inspection or a standards-based protection decision.

High power density creates competing demands: smaller machines reduce material use but increase thermal gradients, acoustic noise, insulation stress, and cooling complexity. Rare-earth magnet supply, recycling, and end-of-life treatment raise environmental and geopolitical concerns. Responsible design should consider efficiency over the complete duty cycle, repairability, material recovery, and safe disposal of oils, resins, and electronic components.

Chapter Summary

Electrical machines are integrated electromagnetic, thermal, mechanical, and insulation systems. The stator and rotor establish the magnetic circuit, while the air gap, bearings, shaft, frame, and enclosure determine mechanical integrity and environmental suitability. Electrical steels reduce hysteresis and eddy-current losses; laminations interrupt circulating currents. Copper and aluminium provide conducting paths, while insulation must withstand electrical, thermal, mechanical, and environmental stress.

Concentrated and distributed windings, coil pitch, winding factor, and DC lap or wave arrangements determine voltage production, harmonic content, torque quality, and current capability. Cooling limits the permissible loss and temperature. Duty classes describe how starting, braking, loading, and rest periods affect thermal stress. Nameplate quantities—including voltage, current, speed, power, efficiency, power factor, duty, insulation class, and enclosure—must be interpreted together.

International protection conventions such as IEC IP codes and NEMA enclosure descriptions are not interchangeable without verification. Safe selection requires attention to earthing, overload protection, hazardous environments, inverter compatibility, cooling at reduced speed, and applicable standards. The central professional lesson is that a machine should be selected for its complete operating cycle and environment, not merely its rated output power.

Key Terms

Electrical steel: Magnetic steel designed to reduce hysteresis and eddy-current losses.

Lamination: Thin insulated sheet used to reduce circulating eddy currents in a magnetic core.

Stator: Stationary magnetic and electrical part of a rotating machine.

Rotor: Rotating magnetic and electrical part of a rotating machine.

Air gap: Clearance between stator and rotor.

Winding: Conductors arranged to produce or receive electromagnetic flux and voltage.

Distributed winding: Winding spread over several slots to shape the magnetomotive force.

Winding factor: Product of pitch and distribution factors for a specified harmonic.

Insulation class: Thermal classification of an electrical insulation system.

Current density: Current divided by conductor cross-sectional area.

Synchronous speed: Speed of the fundamental rotating magnetic field.

Slip: Difference between synchronous speed and induction-motor rotor speed divided by synchronous speed.

Duty type: Standardized description of a machine’s load, starting, braking, and rest cycle.

Thermal resistance: Approximate temperature rise per unit of heat loss.

IP code: IEC enclosure classification for solid-object and water protection.

Power factor: Ratio of real power to apparent power in an AC system.

Service factor: Standard-dependent indication of additional permissible loading under specified conditions.

Inverter-duty motor: Motor designed for operation from a variable-frequency drive over a specified range.

Salient pole: Rotor or stator pole that projects visibly from the magnetic structure.

Equivalent heating current: Current producing approximately the same average copper heating over a duty cycle.

Review Questions

Short Answer Questions

  1. What are the main functions of the stator, rotor, air gap, bearings, and frame?
  2. Why are electrical-machine cores laminated?
  3. Distinguish concentrated and distributed windings.
  4. What information is conveyed by the two numerals in an IEC IP code?
  5. Why can a shaft-mounted fan be inadequate when a motor operates continuously at low speed from an inverter?

Long Answer Questions

  1. Explain the material requirements of electrical-machine cores, conductors, insulation, shafts, and frames.
  2. Compare single-layer, double-layer, lap, wave, and fractional-slot windings.
  3. Discuss the relationship among losses, cooling, temperature rise, insulation class, and service life.
  4. Explain the principal nameplate quantities of a three-phase induction motor and their engineering significance.
  5. Compare IEC duty types S1, S2, S3, S4, and S5, giving one application for each.

Analytical / Application Questions

  1. A four-pole, 50 Hz induction motor runs at 1,455 r/min. Calculate synchronous speed and slip, and explain what the result indicates about motoring operation.
  2. A motor experiences currents of 10 A for 300 s, 4 A for 100 s, and 16 A for 5 s in one cycle. Estimate its equivalent heating current and state the assumptions behind the calculation.
  3. A motor is installed in a dusty packaging plant and operated over a wide speed range by a variable-frequency drive. Recommend the important enclosure, cooling, insulation, protection, and nameplate specifications that must be checked before purchase.

Multiple Choice Questions with Answers

Question 1

Which component provides the stationary magnetic circuit and commonly contains the AC winding?

A. Rotor

B. Stator

C. Shaft

D. Bearing

Correct Answer: B. Stator

Question 2

Why are magnetic cores made from laminations?

A. To increase mechanical friction

B. To reduce circulating eddy-current losses

C. To increase conductor current density

D. To eliminate hysteresis completely

Correct Answer: B. To reduce circulating eddy-current losses

Question 3

A four-pole, 50 Hz machine has what synchronous speed?

A. 750 r/min

B. 1,000 r/min

C. 1,500 r/min

D. 3,000 r/min

Correct Answer: C. 1,500 r/min

Question 4

Which winding is generally spread over several slots to obtain a more nearly sinusoidal magnetomotive force?

A. Distributed winding

B. Concentrated winding

C. Squirrel-cage winding

D. Field-shunt winding

Correct Answer: A. Distributed winding

Question 5

What does the first numeral of an IEC IP code primarily describe?

A. Insulation temperature class

B. Protection against solids and access

C. Power factor

D. Cooling-medium temperature

Correct Answer: B. Protection against solids and access

Question 6

For a balanced three-phase sinusoidal load, which expression gives real input power?

A. P = V_L I_L

B. P = I²R only

C. P = √3 V_L I_L cosφ

D. P = 2πnT only

Correct Answer: C. P = √3 V_L I_L cosφ

Question 7

A motor operates at 1,455 r/min while its synchronous speed is 1,500 r/min. What is its slip?

A. 1.5%

B. 3%

C. 30%

D. 97%

Correct Answer: B. 3%

Question 8

Which duty includes significant starting effects in addition to intermittent operation?

A. S1

B. S2

C. S3

D. S4

Correct Answer: D. S4

Question 9

What is the principal risk of connecting a motor marked 230/400 V Δ/Y in delta to a 400 V line-to-line supply?

A. The phase voltage is excessive

B. The rotor becomes stationary by definition

C. The frequency becomes zero

D. The enclosure rating changes automatically

Correct Answer: A. The phase voltage is excessive

Question 10

Why may independent ventilation be required for an inverter-fed motor at low speed?

A. The air gap disappears at low speed

B. The shaft-mounted fan moves less air

C. The insulation class changes to Class A

D. The synchronous speed becomes independent of frequency

Correct Answer: B. The shaft-mounted fan moves less air

Electrical Machines and Drives
Chapter 2 of 15