Doors, Stairs & Windows

Chapter 11
Performance-Based Selection and Specification

Diploma of Civil Draftsman
Doors, Stairs & Windows   •   Diploma

Performance-Based Selection and Specification

Introduction

Doors, stairs and windows are not merely components placed in openings. They are building assemblies that control movement, safety, comfort, energy use, security, daylight, ventilation and maintenance. A door may be required to resist fire and smoke while also permitting rapid evacuation. A window may need to admit daylight and fresh air while limiting heat gain, noise and water penetration. A stair must support people safely, remain accessible and maintain its function during emergencies.

Traditional specification often selects products by material or appearance: “a timber door,” “an aluminium window,” or “a concrete stair.” Performance-based specification begins with a different question: What must the assembly do, under what conditions, and for how long? The material and construction are then selected to achieve measurable outcomes.

This approach is strategic because it links design decisions to the building’s purpose, regulatory obligations, climate, users, risk profile and whole-life cost. It also gives the civil draftsman an important professional role. Drawings and schedules must communicate performance requirements accurately enough for manufacturers, contractors, inspectors and facility managers to act on them.

Learning Objectives

By the end of this chapter, the student should be able to:

  1. Explain the difference between prescriptive and performance-based specification.
  2. Identify the main performance criteria for doors, stairs and windows.
  3. Relate fire, acoustic, security, thermal, daylight, ventilation and weather requirements to assembly selection.
  4. Prepare coordinated performance specifications and schedules.
  5. Apply a basic multi-criteria and life-cycle cost decision process.
  6. Recognise testing, certification, installation and maintenance requirements.
  7. Evaluate a building-opening solution against user needs, regulations and practical limitations.

1. From Product Selection to Performance Specification

A prescriptive specification states what an assembly is made of or how it is constructed. For example, it may require a 45 mm solid-core timber door with steel hinges. A performance specification states the required result, such as a minimum fire-resistance period, maximum air leakage, minimum acoustic rating or specified security class. A hybrid specification uses both approaches: it states essential performance values and identifies acceptable materials or proprietary systems.

Performance-based selection normally follows this sequence:

  1. Define the building use and users. Identify occupancy, age, mobility, sensory needs, working patterns and security expectations.
  2. Identify hazards and exposures. Consider fire, smoke, impact, forced entry, wind, rain, solar radiation, noise and condensation.
  3. Set measurable performance criteria. Use recognised standards, codes, test methods and project requirements.
  4. Select an assembly concept. Consider leaf, frame, glazing, hardware, seals, thresholds, finishes, fixings and interfaces.
  5. Verify evidence. Require test reports, classifications, calculations, declarations, samples and installation instructions.
  6. Coordinate the design. Check clear openings, structural support, services, drainage, accessibility, escape routes and adjacent finishes.
  7. Plan operation and maintenance. Ensure that performance can be retained throughout the service life.

The performance of an assembly is not necessarily equal to the performance of its separate components. A fire-rated door leaf may fail if the frame, closer, hinges, seals or wall junction are unsuitable. A high-performance window may perform poorly if it is badly installed or if perimeter seals are discontinuous. This is known as system performance.

2. A Performance Framework

A useful project brief can classify requirements into four groups:

Requirement groupTypical questionsExamples of evidence
Safety and complianceWill people be protected during normal use and emergencies?Code review, fire test, accessibility inspection
Environmental performanceWill the assembly control heat, light, air, water and sound?U-value, solar factor, acoustic test, water test
Operational performanceWill it open, close, lock and withstand use?Cycle testing, hardware rating, security test
Value and user experienceIs it affordable, maintainable and appropriate?Life-cycle cost, user consultation, maintenance plan

Requirements can conflict. Increasing glazing may improve daylight but increase solar heat gain. A tighter window may reduce uncontrolled ventilation but require a deliberate ventilation strategy. A heavier security door may improve resistance to attack but increase opening force and reduce accessibility. The designer must therefore optimise the assembly rather than maximise one property in isolation.

A practical decision matrix can assign each criterion a weight and score each option. If Si is the score of option i, wj is the importance weight of criterion j, and rij is the rating of option i for criterion j, then:

Si = ∑(j=1 to n) wj rij

The weights should sum to 1. Ratings must use a consistent scale, such as 1 to 5. This method supports judgement; it does not replace code compliance. An option that fails a mandatory fire or accessibility requirement must be rejected, regardless of its total score.

3. Fire and Life Safety

3.1 Fire-resistance concepts

Fire performance involves several related properties:

  • Fire resistance: the ability of an assembly to maintain specified functions for a stated period under a standard fire exposure.
  • Integrity: the ability to prevent flames and hot gases from passing through.
  • Insulation: the ability to limit temperature rise on the unexposed side.
  • Load-bearing capacity: the ability to continue carrying structural load where applicable.
  • Smoke control: the ability to restrict the movement of smoke, often requiring tested smoke seals and controlled gaps.
  • Reaction to fire: how a material contributes to ignition, flame spread and smoke production.

A fire door is a complete tested assembly. The leaf, frame, glazing, hinges, latch, closer, seals, threshold and wall construction must be compatible with the required classification. Substitution of hardware or glazing without approval may invalidate the test evidence.

3.2 Doors on escape routes

Doors serving escape routes must be assessed for direction of opening, clear width, opening force, panic or emergency hardware, hold-open arrangements and protection against fire and smoke. A fire door should not be wedged open. Where automatic hold-open devices are used, they should release on fire detection or power failure as required by the governing code.

The draftsman should show door swings, fire ratings, hardware sets, vision panels, thresholds and signage. The schedule should identify whether the door is self-closing, smoke-sealed, fire-rated on one or both faces, or required to remain unlocked during escape.

3.3 Stairs and fire safety

Stairs form part of the means of escape and must provide stable, continuous and visible travel. Important requirements commonly include protected enclosures, fire-resisting walls and doors, non-slip treads, handrails, edge visibility, emergency lighting and protection from smoke. Storage, services and combustible finishes should not compromise the escape route.

Fire requirements are jurisdiction-specific. The applicable building code and approved test classification must always take precedence over generic textbook values.

4. Acoustic Performance

Doors and windows are frequent weak points in an otherwise well-insulated wall. Sound transmission occurs through the element itself and through flanking paths around frames, thresholds, service penetrations and ventilation openings.

Common acoustic criteria include airborne sound insulation, impact sound control and equipment noise. A laboratory rating describes a tested specimen under controlled conditions; field performance may be lower because of workmanship and flanking transmission. Acoustic specifications should therefore identify the test method, rating, frequency range where relevant, laboratory or field basis, and installation conditions.

For a simple transmission comparison, sound reduction is expressed in decibels. The sound pressure level difference between two locations may be represented as:

D = L1 − L2

where D is the level difference in dB, L1 is the source-side sound level in dB, and L2 is the receiving-side level in dB. This is not, by itself, a complete rating of a door or window because room absorption, area, flanking and frequency affect field results.

Acoustic improvement commonly depends on:

  • increased mass or a multi-layer construction;
  • separated or laminated glass;
  • double or triple seals;
  • tight meeting stiles and thresholds;
  • acoustically sealed frame perimeters;
  • avoidance of unsealed trickle vents or service gaps; and
  • control of flanking through adjacent walls and ceilings.

A window selected for a busy road should not be specified only as “double glazed.” The specification should identify glazing composition, frame type, seals, ventilation strategy and the required tested acoustic rating. If background ventilation is required, the acoustic performance of the ventilator must be included.

5. Security and Robustness

Security is a risk-management problem rather than a simple choice of a stronger lock. Threats may include opportunistic entry, forced attack, vandalism, unauthorised duplication of keys, vehicle impact and internal misuse.

A security assessment considers:

  • location and accessibility of the opening;
  • value or sensitivity of contents;
  • visibility and passive surveillance;
  • door or window leaf strength;
  • frame anchorage and wall strength;
  • hinges, cylinders, multipoint locks and strike plates;
  • glazing type and bead location;
  • electronic access control and power-failure behaviour; and
  • emergency egress and fire requirements.

Security hardware must not create an unacceptable life-safety hazard. For example, an escape door may require controlled access from outside but free egress from inside. Access-control systems should be coordinated with fire alarm release, emergency power and disability access.

Robustness also includes resistance to repeated operation and accidental impact. Public buildings usually require more durable finishes and hardware than lightly used private spaces. Door closers should be selected so that the force needed to overcome them remains compatible with accessibility requirements.

6. Thermal Performance and Condensation

Windows and glazed doors often have higher heat transfer than insulated opaque walls. Thermal performance depends on glazing, frame, spacers, edge conditions, seals and installation.

The steady-state heat flow through a building element can be approximated by:

Q = U A ∆T

where Q is heat flow in watts (W), U is thermal transmittance in W/(m²·K), A is area in m², and ∆T is the temperature difference across the element in K or °C. The equation assumes steady conditions and a uniform effective U-value. It does not include solar gains, thermal bridges, air leakage or transient storage.

For example, a window with U = 1.8 W/(m²·K), area A = 3 m², and indoor–outdoor temperature difference ∆T = 15 K has:

Q = 1.8 × 3 × 15 = 81 W

This is conductive heat flow under the stated conditions. Actual building energy use also depends on solar radiation, shading, orientation, internal gains, ventilation and heating or cooling operation.

Condensation occurs when a surface temperature falls below the air dew-point temperature. Risk is increased by high indoor humidity, cold frames, metal spacers, thermal bridges and poor air circulation. Selection should therefore consider whole-window U-value rather than centre-of-glass data alone. Warm-edge spacers, thermally broken frames, insulated reveals and continuous air seals can improve performance.

7. Daylight, Solar Control and Glare

Windows provide daylight and visual connection, but excessive glazing may produce glare, overheating and loss of privacy. Selection should consider orientation, window-to-wall ratio, glass visible transmittance, external shading, internal blinds, room depth and surrounding obstructions.

A basic daylight factor is expressed as:

DF = (Ei ÷ Eo) × 100%

where DF is daylight factor, Ei is indoor illuminance at a specified point in lux, and Eo is simultaneous unobstructed outdoor illuminance in lux. The concept assumes an overcast sky and is not a complete prediction of daylight autonomy, glare or direct sunlight. Modern design may instead use climate-based annual simulations.

Solar control can be achieved through orientation, overhangs, fins, external blinds, low-emissivity coatings, tinted or spectrally selective glazing and vegetation. External shading is often more effective than internal blinds because it intercepts solar radiation before it enters the room. However, shading must be coordinated with cleaning, wind exposure, fire spread and maintenance.

8. Ventilation and Indoor Air Quality

Ventilation may be natural, mechanical or hybrid. An opening window can provide user control, purge ventilation and psychological benefits, but its effectiveness depends on wind, temperature difference, opening area, insect screens, noise and outdoor air quality.

For a space with volume V and a required air-change rate n, the approximate airflow is:

q = nV

where q is airflow in m³/h when n is in air changes per hour and V is in m³. This simplified relationship assumes the required air change is known and evenly distributed. It does not predict natural ventilation through a particular window; wind pressure, buoyancy and opening discharge characteristics must also be considered.

Ventilators should be assessed for airflow, controllability, weather resistance, insect protection and acoustic attenuation. Windows in hazardous locations may require restrictors. Opening limitations must not prevent required smoke ventilation or emergency access unless an alternative strategy is provided.

9. Weather Exposure and Water Management

External doors and windows are exposed to wind pressure, driving rain, ultraviolet radiation, temperature change and, in coastal locations, salt. Performance depends on both product resistance and installation detailing.

Key design measures include:

  • projecting sills and drips;
  • sloped surfaces that shed water;
  • drained and ventilated glazing rebates where appropriate;
  • sealed but flexible perimeter joints;
  • end dams and weep paths;
  • compatible flashings and membranes;
  • corrosion-resistant fixings; and
  • protection of thresholds from ponding and splashback.

A sealant joint is not a substitute for drainage. Water that enters a frame must have a controlled path out without wetting vulnerable materials. Movement between dissimilar materials must be accommodated by joint width, backing material and sealant movement capability.

Weather performance should be specified using recognised air, water and wind test classifications suitable for the exposure zone. Coastal, high-rise and hurricane-prone sites may require enhanced design pressures and corrosion protection. The draftsman must show interfaces clearly because many failures occur at the sill, head, jamb or threshold rather than in the centre of the product.

10. Accessibility, Ergonomics and User Needs

A performance-based selection must serve the full range of users. Important factors include clear passage width, threshold height, opening force, lever-handle operation, visual contrast, tactile information, handrail continuity, landing dimensions and resting opportunities.

Doors should be usable by people with limited strength, reach or vision. Glazed doors require visible manifestation or contrasting markings where required. Stairs should have consistent riser and going dimensions, secure handrails, adequate lighting and slip-resistant nosings. Stair geometry must comply with the applicable code; a visually attractive stair with inconsistent dimensions is unsafe.

User needs may differ by building type. A hospital requires quiet, cleanable and easily operated doors. A school requires impact resistance, finger protection and robust hardware. A dwelling may prioritise privacy, daylight and occupant control. An industrial facility may require chemical resistance, high-cycle hardware and controlled access.

11. Life-Cycle Cost and Maintainability

Lowest initial price is not necessarily lowest cost. A life-cycle assessment considers purchase, installation, energy, cleaning, inspection, repair, replacement and disposal.

A simplified present-value model is:

LCC = C0 + ∑(t=1 to N) [Ct ÷ (1 + r)t]

where LCC is life-cycle cost, C0 is initial cost, Ct is cost in year t, r is the annual discount rate as a decimal, and N is the analysis period in years. The model assumes future costs can be estimated and discounted consistently. It should be expanded when energy escalation, residual value, replacement cycles or uncertainty are significant.

For example, suppose an assembly costs £10,000 initially, requires £600 at the end of each of years 1–5, and uses a discount rate of 5%. The present value of maintenance is approximately:

600 × [1/1.05 + 1/1.05² + 1/1.05³ + 1/1.05⁴ + 1/1.05⁵] ≈ £2,596

Therefore, the simplified life-cycle cost is approximately £12,596, excluding energy and replacement. Currency, tax, inflation and discount assumptions must be stated in a real project.

Maintainability should influence selection from the beginning. Replaceable seals, accessible closers, standard hardware, durable finishes, documented cleaning methods and available spare parts can reduce future disruption. A highly specialised product may be unsuitable if replacement components are unavailable locally.

12. Specification and Drawing Practice

A complete opening schedule should identify, as applicable:

ItemInformation to communicate
IdentificationOpening number, location and room reference
GeometryWidth, height, sill level, frame depth and handing
FunctionAccess, escape, ventilation, daylight or service use
PerformanceFire, smoke, acoustic, thermal, security and weather criteria
ComponentsLeaf, frame, glazing, seals, threshold and hardware
FinishColour, coating, corrosion protection and durability
InterfacesWall construction, membranes, flashings, fixings and sealants
VerificationTest evidence, samples, shop drawings and inspection requirements
OperationCloser, hold-open, restrictor, access control and maintenance

Specifications should avoid contradictory statements. If a door is described as both “non-rated” and “60-minute fire-rated,” the conflict must be resolved before tender. Generic phrases such as “high quality” or “weatherproof” should be replaced with measurable requirements or referenced standards.

Shop drawings should show frame anchorage, setting blocks, packers, sealant joints, drainage paths, thresholds and adjacent finishes. Coordination with structural, mechanical, electrical and fire systems is essential. For example, a window restrictor, sprinkler head or duct must not interfere with escape, cleaning or operation.

13. Verification, Quality Control and Commissioning

Performance claims require evidence. Acceptable evidence may include independent test reports, certification, product declarations, calculations by a competent person, site inspection records and commissioning results. The evidence must correspond to the exact product configuration, including dimensions, glazing, hardware and installation method.

Quality control should occur at four stages:

  1. Design review: confirm requirements, interfaces and code obligations.
  2. Submittal review: check test evidence, samples and proposed substitutions.
  3. Installation inspection: verify plumb frames, anchors, seals, drainage, clearances and hardware.
  4. Handover and operation: test closers, locks, access control, smoke seals, restrictors and ventilation controls; provide maintenance information.

A substitution should be treated as a design change, not merely a procurement decision. The replacement must be re-evaluated against all relevant criteria, including appearance, fire certification, acoustic performance, thermal bridges, lead time and spare parts.

14. Illustrative Case Study: Community Health Centre

Background

A proposed community health centre contains consultation rooms, a waiting area, a small treatment department and administrative offices. The site faces a busy road and receives strong afternoon sun. The building must provide accessible circulation, privacy, controlled access and reliable fire escape.

Problem

The initial design used large, low-cost windows and standard hollow-core internal doors. During design review, several risks were identified: road noise in consultation rooms, afternoon overheating, inadequate privacy, weak security at the staff entrance and excessive opening force at some fire doors.

Analysis

The project team mapped requirements by space. Consultation rooms required speech privacy, glare control and controllable ventilation. The waiting area required daylight, views and robust doors. The staff entrance required access control but free emergency egress. Fire doors needed compatible closers, smoke seals and approved hardware. Maintenance staff requested standard components and accessible replacement parts.

Approach and solution

The team selected acoustic laminated glazing for consultation rooms, combined with sealed frames and acoustically rated ventilators. External horizontal shading was introduced on the sun-exposed façade. The waiting area retained larger windows but used solar-control glazing and glare management. Staff access was controlled by an electronic lock connected to the fire alarm release system, while the internal escape side remained operable without a key.

Door closers were selected after checking opening-force requirements and were coordinated with the fire-door certification. A durable, cleanable finish was specified in clinical areas. Threshold details were revised to maintain accessibility and prevent rainwater entry. The opening schedule recorded performance ratings, hardware sets, test evidence and maintenance responsibilities.

Outcome

The revised design met the project’s safety and accessibility requirements while improving acoustic comfort and solar control. Although initial window and hardware costs increased, projected maintenance and energy risks were reduced. The case also demonstrated that performance requirements must be considered together: a sealed acoustic window required a planned ventilation solution, and a secure access system required fire-alarm coordination.

Learning points

  • Evaluate the complete assembly, not an isolated product.
  • Identify conflicts between security, fire safety, accessibility and ventilation early.
  • Treat interfaces and installation as part of performance.
  • Use evidence that matches the proposed configuration.
  • Consider whole-life value rather than initial purchase price alone.

15. Challenges, Limitations and Contemporary Practice

Performance-based specification can be difficult when requirements are vague, test data are incomplete or different standards use incompatible classifications. Ratings obtained in laboratories may not represent field performance. Multi-criteria scoring can create false precision if scores are subjective. Life-cycle calculations are sensitive to uncertain energy prices, maintenance intervals and replacement dates.

Digital building information modelling can improve coordination by associating openings with performance data, maintenance requirements and revision histories. Digital product passports and structured manufacturer data may improve traceability. Computational daylight and thermal analysis can test options before construction. AI-assisted design tools may help compare alternatives or detect schedule inconsistencies, but their outputs must be checked by competent professionals. AI does not replace code interpretation, certified testing, site inspection or professional responsibility.

Sustainable practice increasingly considers embodied carbon, repairability, disassembly and material health. A durable assembly that can be repaired may be preferable to a theoretically efficient product that must be completely replaced after minor damage. Designers should also consider overheating under future climate conditions, resilience to extreme weather and the social consequences of poor indoor environmental quality.

Best-Practice Checklist

Before issuing a door, stair or window specification, confirm that:

  • mandatory code and fire requirements have been identified;
  • user groups and accessibility needs have been considered;
  • performance criteria are measurable and unambiguous;
  • the complete assembly and its interfaces are defined;
  • acoustic, thermal, daylight and ventilation requirements are coordinated;
  • weather exposure and drainage are detailed;
  • security does not compromise escape or accessibility;
  • test evidence matches the proposed configuration;
  • installation, inspection and commissioning are specified;
  • cleaning, maintenance and replacement are practical; and
  • substitutions require documented technical review.

Chapter Summary

Performance-based selection starts with required outcomes rather than a preferred material. Doors, stairs and windows must be assessed as complete assemblies whose performance depends on components, interfaces, installation and maintenance. Fire safety requires attention to integrity, insulation, smoke control, escape operation and certified hardware. Acoustic performance depends on mass, seals, glazing, thresholds and flanking paths. Security must be balanced with emergency egress and accessibility.

Thermal performance can be estimated using Q = UA∆T, while daylight and ventilation require appropriate calculations and careful recognition of their assumptions. Weather resistance depends on drainage, flashings, seals and exposure classification. User needs include safe stair geometry, manageable opening forces, visual contrast, privacy and controllability. Life-cycle cost analysis helps compare initial expenditure with maintenance, energy and replacement costs.

A professional specification communicates measurable criteria, evidence requirements, interfaces and responsibilities. Drawings, schedules, shop drawings, inspections and commissioning must work together. The central professional principle is to select and document assemblies that remain safe, usable, durable and valuable throughout their intended service life.

Key Terms

Air leakage: Uncontrolled movement of air through gaps or joints in an assembly.

Assembly: A coordinated set of components that functions as one building element.

Daylight factor: Indoor illuminance expressed as a percentage of simultaneous outdoor illuminance under defined sky conditions.

Fire integrity: Ability to prevent flames and hot gases from passing through an assembly for a stated period.

Fire insulation: Ability to limit temperature rise on the unexposed side of a fire-tested assembly.

Flanking transmission: Sound travelling around, rather than directly through, a separating element.

Life-cycle cost: Present value of initial, operating, maintenance, replacement and disposal costs over an analysis period.

Performance-based specification: Specification defined by required measurable outcomes rather than only materials or construction methods.

Prescriptive specification: Specification that directly states materials, dimensions or construction methods.

Solar control: Measures used to manage solar heat gain, glare and sunlight.

Thermal bridge: Localised area of increased heat flow through or around a building envelope.

Thermal transmittance: Rate of heat transfer through an element per unit area and temperature difference, expressed as U-value.

Weather seal: Component or joint treatment that limits air and water penetration.

Smoke seal: Seal designed to restrict smoke movement around a closed door.

Security classification: Categorisation of resistance to defined attack methods or threat levels.

System performance: Performance of the complete assembly, including components, interfaces and installation.

Test evidence: Certified or documented information demonstrating compliance with a stated requirement.

User needs: Functional, safety, comfort, accessibility and operational requirements of building occupants.

Review Questions

Short Answer Questions

  1. What is the main difference between prescriptive and performance-based specification?
  2. Why must a fire door be treated as a complete tested assembly?
  3. Name four factors that influence the acoustic performance of a window.
  4. What information does the U-value represent?
  5. Why is drainage important in the weatherproofing of windows and doors?

Long Answer Questions

  1. Explain how fire safety, accessibility and security requirements may conflict at an entrance door. How should the conflict be resolved?
  2. Discuss the main factors that should be considered when specifying windows for a noisy, sun-exposed urban site.
  3. Explain the role of drawings, schedules, test evidence, installation inspection and commissioning in achieving specified performance.
  4. Describe the advantages and limitations of life-cycle cost analysis for doors and windows.
  5. Explain why the performance of an assembly may be lower than the performance of its individual components.

Analytical / Application Questions

  1. A consultation room faces a busy road and experiences afternoon overheating. Propose a window and ventilation strategy, identifying acoustic, thermal, daylight, glare and maintenance considerations.
  2. Compare two entrance-door options using a weighted decision matrix. Include fire safety, security, accessibility, durability, appearance and life-cycle cost, and justify the weights you select.
  3. Review a proposed escape stair and adjacent fire door in a public building. Prepare a checklist of potential failures involving geometry, handrails, lighting, door operation, smoke control, signage and maintenance.

Multiple Choice Questions with Answers

Question 1

Which statement best describes a performance-based specification?

A. It specifies only the brand and colour of a product.

B. It defines measurable outcomes that an assembly must achieve.

C. It eliminates the need for testing and inspection.

D. It applies only to structural components.

Correct Answer: B. It defines measurable outcomes that an assembly must achieve.

Question 2

Which item is normally part of a complete fire-door assembly?

A. Only the door leaf

B. Only the frame and wall

C. Leaf, frame, hardware, seals and compatible installation

D. Paint colour and room furniture

Correct Answer: C. Leaf, frame, hardware, seals and compatible installation

Question 3

Using Q = UA∆T, what is the conductive heat flow through a 3 m² window with U = 1.8 W/(m²·K) and ∆T = 15 K?

A. 27 W

B. 54 W

C. 81 W

D. 270 W

Correct Answer: C. 81 W

Question 4

Which measure generally intercepts solar radiation before it enters a building?

A. External shading

B. Internal carpet

C. A door closer

D. A thicker threshold

Correct Answer: A. External shading

Question 5

What is a major acoustic weakness in a nominally sound-insulating window?

A. A continuous perimeter seal

B. An unsealed frame perimeter or ventilation gap

C. Laminated glazing

D. A properly sealed threshold

Correct Answer: B. An unsealed frame perimeter or ventilation gap

Question 6

In the simplified life-cycle cost equation, what does r represent?

A. Room volume

B. Resistance to forced entry

C. Annual discount rate

D. Relative humidity

Correct Answer: C. Annual discount rate

Question 7

Why must a security system be coordinated with the fire alarm?

A. To increase window daylight

B. To ensure controlled doors release or permit safe escape when required

C. To reduce the U-value of glazing

D. To eliminate all maintenance

Correct Answer: B. To ensure controlled doors release or permit safe escape when required

Question 8

For q = nV, what does n represent when q is in m³/h?

A. Air changes per hour

B. Window area in m²

C. Noise level in dB

D. Number of door hinges

Correct Answer: A. Air changes per hour

Question 9

Which statement about laboratory acoustic ratings is most accurate?

A. They always equal field performance.

B. They are irrelevant to installation quality.

C. Field performance may be lower because of flanking and workmanship.

D. They measure only thermal insulation.

Correct Answer: C. Field performance may be lower because of flanking and workmanship.

Question 10

What should happen when a proposed product substitution changes the tested hardware configuration of a fire door?

A. It should be accepted automatically if the appearance is similar.

B. It should be treated as a technical change and re-evaluated.

C. It should be ignored if the product is cheaper.

D. It should be approved only by the occupant.

Correct Answer: B. It should be treated as a technical change and re-evaluated.

Doors, Stairs & Windows
Chapter 11 of 15