Basic Electronics Engineering

Chapter 1
Electrical and Electronic Engineering Foundations

Bachelors Program in Electrical Engineering
Basic Electronics Engineering   •   Bachelor

Electrical and Electronic Engineering Foundations

Introduction

Electrical engineering describes the production, transmission, conversion, measurement, and control of electrical energy and information. Electronic engineering applies the same physical laws to devices and circuits that process signals, often at comparatively low power. Both disciplines depend on a common foundation: voltage, current, energy, circuit laws, network models, alternating-current analysis, signals, measurement, and safety.

Circuit theory is principally a lumped-parameter approximation. Components are treated as localized elements connected by ideal conductors. This approximation is effective when circuit dimensions are much smaller than the electromagnetic wavelength and propagation delay is negligible relative to the timescale of interest. At high frequencies, long conductors become transmission lines, and parasitic resistance, capacitance, and inductance can no longer be ignored.

Learning Objectives

After studying this chapter, students should be able to:

  • apply voltage, current, power, and energy relationships using consistent reference directions;
  • use Kirchhoff’s current and voltage laws in lumped circuits;
  • analyze networks using superposition, source transformation, and Thévenin and Norton equivalents;
  • calculate sinusoidal quantities, impedance, phasor current, and complex power;
  • interpret time-domain signals, spectra, bandwidth, sampling, and decibels;
  • evaluate loading, grounding, and measurement uncertainty;
  • select and connect common laboratory instruments appropriately; and
  • identify electrical hazards and apply safe laboratory practice.

1. Electrical Quantities and Reference Conventions

1.1 Charge and current

Electric charge is measured in coulombs (C). Current is the time rate of charge flow:

i(t) = \frac{dq(t)}{dt}

Here, i(t) is instantaneous current in amperes (A), and q(t) is charge in coulombs. One ampere equals one coulomb per second. Conventional current points in the direction that positive charge would move; electron motion in metals is opposite to conventional current.

A current arrow is a reference direction rather than a claim about the eventual sign. If calculation produces a negative current, the physical current flows opposite to the selected arrow.

1.2 Voltage

Voltage is electric potential difference, or energy transferred per unit charge:

vab = \frac{dw}{dq} = Va - Vb

The voltage vab is measured from node b to node a in volts (V), while w denotes energy in joules (J). Thus, one volt equals one joule per coulomb.

Voltage must always be specified between two points. Statements such as “the voltage at node a” implicitly require a reference node, commonly called ground and assigned zero potential.

1.3 Power, energy, and the passive sign convention

Under the passive sign convention, current is referenced as entering the terminal marked positive for voltage. Instantaneous power absorbed by the element is then

p(t) = v(t)i(t)

Positive power means that the element absorbs energy; negative power means that it delivers energy. Energy transferred over the interval from t1 to t2 is

w = \intt1t2 p(t)\,dt

Power is measured in watts (W), equivalent to joules per second, while energy is measured in joules or, in utility applications, watt-hours. One kilowatt-hour is 3.6 × 106 J.

For a constant voltage and current, W = VIt. This is a special DC result, not a replacement for the general integral.

Worked Example 1: Power balance

A 12 V source supplies 3 A to a resistive network. With current leaving the source’s positive terminal, the source delivers

ps = -(12)(3) = -36\ \text{W}

If two resistors absorb 12 W and 24 W, total absorbed power is 36 W. The algebraic sum of powers is zero:

\sum p = -36 + 12 + 24 = 0

This balance expresses conservation of energy and is a valuable check on circuit calculations.

2. Ideal Circuit Elements

The principal linear passive elements are resistance, capacitance, and inductance.

ElementConstitutive relationshipStored or dissipated energy
Resistorv = Rip = i2R = v2/R is dissipated as heat
Capacitori = C\,dv/dtwC = \tfrac{1}{2}Cv2
Inductorv = L\,di/dtwL = \tfrac{1}{2}Li2

Resistance R is measured in ohms (Ω), capacitance C in farads (F), and inductance L in henries (H). The resistor equations assume an ideal ohmic resistor with constant R. Real component values vary with temperature, frequency, voltage, and manufacturing tolerance.

An ideal capacitor’s voltage cannot change instantaneously unless an impulse current is applied. Similarly, an ideal inductor’s current cannot change instantaneously unless an impulse voltage is applied. These continuity properties provide initial conditions for transient analysis.

Independent voltage and current sources prescribe voltage or current regardless of the remaining circuit. Dependent sources are controlled by another circuit variable and are essential models for transistors and operational amplifiers. They remain active when equivalent resistance is found by suppressing independent sources.

3. Kirchhoff’s Laws

3.1 Kirchhoff’s current law

Kirchhoff’s current law (KCL) follows from conservation of charge. For a lumped node with no modeled charge accumulation,

\sumk=1n ik = 0

Currents entering and leaving must be assigned consistent signs. Equivalently, total current entering a node equals total current leaving it.

3.2 Kirchhoff’s voltage law

Kirchhoff’s voltage law (KVL) states that the directed sum of voltages around a closed lumped-circuit path is zero:

\sumk=1n vk = 0

This form assumes that no unmodeled time-varying magnetic flux links the loop. If such flux is present, Faraday’s law introduces an induced electromotive force. In circuit models, this effect is represented by mutual inductance or an induced-voltage source.

Worked Example 2: Series-parallel network

A 12 V ideal source supplies a 2 Ω resistor in series with a parallel combination of 6 Ω and 3 Ω. The parallel equivalent is

Rp = \frac{(6)(3)}{6+3} = 2\ \Omega

The total resistance is 4 Ω, so source current is 12/4 = 3 A. The series resistor drops (3)(2)=6 V, leaving 6 V across the parallel branches. Branch currents are therefore 1 A through 6 Ω and 2 A through 3 Ω. KCL is satisfied because 3 = 1 + 2 A.

The resistor powers are 18 W, 6 W, and 12 W, totaling 36 W—the power delivered by the source.

4. Network Theorems

Network theorems simplify analysis and reveal how a circuit interacts with a load.

4.1 Superposition

In a linear circuit containing multiple independent sources, a voltage or current response equals the algebraic sum of the responses produced by each independent source acting alone. When one source acts alone:

  • replace an ideal independent voltage source by a short circuit;
  • replace an ideal independent current source by an open circuit;
  • retain dependent sources;
  • retain element impedances.

Superposition applies directly to voltages and currents, not to nonlinear quantities such as power. Power must be calculated from the total voltage and current after superposition.

4.2 Source transformation

An ideal voltage source Vs in series with resistance Rs is terminally equivalent to an ideal current source

Is = \frac{Vs}{Rs}

in parallel with the same resistance. The transformation preserves external terminal behavior but not necessarily internal current or power.

4.3 Thévenin and Norton equivalents

Any linear two-terminal network can be represented at its terminals by either:

  • a Thévenin voltage Vth in series with Rth or Zth; or
  • a Norton current IN in parallel with the same resistance or impedance.

The relationships are

Vth = IN Rth, \qquad IN = \frac{Vth}{Rth}

For AC networks, resistance is replaced by complex impedance. The open-circuit terminal voltage is Vth, and the short-circuit current is IN.

To find equivalent resistance in a resistive network, suppress independent sources and calculate the resistance seen at the terminals. If dependent sources are present, retain them and apply a test source, using Rth=Vtest/Itest.

4.4 Maximum power transfer

For a resistive Thévenin source, load power is

PL = \frac{Vth2RL}{(Rth+RL)2}

Differentiating with respect to RL shows that maximum power occurs at

RL = Rth, \qquad PL,max = \frac{Vth2}{4Rth}

This condition gives only 50% efficiency because equal power is dissipated internally. Power systems therefore usually prioritize efficiency rather than maximum power transfer. In AC circuits, maximum average power occurs under conjugate matching: ZL = Zth*.

Worked Example 3: Thévenin equivalent

A 12 V source feeds a divider consisting of 2 kΩ above a 4 kΩ resistor. A load is to be connected across the 4 kΩ resistor. With the load removed,

Vth = 12\left(\frac{4}{2+4}\right)=8.00\ \text{V}

After suppressing the ideal voltage source,

Rth = 2\ \text{k}\Omega \parallel 4\ \text{k}\Omega = 1.333\ \text{k}\Omega

The resistive load receiving maximum power is 1.333 kΩ, and

PL,max = \frac{82}{4(1333.3)} \approx 0.0120\ \text{W}=12.0\ \text{mW}

5. Sinusoidal Steady-State Analysis

5.1 Sinusoids, frequency, and phase

A sinusoidal voltage can be written

v(t)=Vm\cos(\omega t+\phi)

Here Vm is peak amplitude, \omega is angular frequency in rad/s, \phi is phase in radians or degrees, and

\omega=2\pi f, \qquad T=\frac{1}{f}

Frequency f is measured in hertz (Hz), and period T in seconds.

For a sinusoid, root-mean-square voltage and current are

Vrms=\frac{Vm}{\sqrt{2}}, \qquad Irms=\frac{Im}{\sqrt{2}}

More generally, the RMS value of a periodic waveform is

Xrms=\sqrt{\frac{1}{T}\int0T x2(t)\,dt}

RMS represents the DC-equivalent heating effect in a resistor. The peak-to-RMS relationship above applies only to a sinusoid.

5.2 Phasors and impedance

A phasor represents the magnitude and phase of a sinusoid at one frequency. Using RMS phasors, Ohm’s law becomes

\underline{V}=\underline{I}Z

where complex impedance is measured in ohms. For ideal elements,

ZR=R, \qquad ZL=j\omega L, \qquad ZC=\frac{1}{j\omega C}=-\frac{j}{\omega C}

The symbol j=\sqrt{-1} is used in electrical engineering to avoid confusion with current. Inductive reactance is positive; capacitive reactance is negative.

Worked Example 4: Series RC circuit

A 1.00 kΩ resistor and 1.00 μF capacitor are connected in series to a 10.0 V RMS, 100 Hz source. Capacitive reactance is

XC=\frac{1}{2\pi fC}=\frac{1}{2\pi(100)(1.00×10-6)}=1591.5\ \Omega

Thus,

Z=1000-j1591.5=1879.6\angle -57.9^\circ\ \Omega

Taking source voltage as the zero-phase reference,

\underline{I}=\frac{10.0\angle0^\circ}{1879.6\angle-57.9^\circ}
=5.32\angle+57.9^\circ\ \text{mA}

Therefore, current leads the applied voltage by approximately 57.9°. This is consistent with the net capacitive impedance.

5.3 Complex power

For RMS phasors, complex power is explicitly defined by

\underline{S}=P+jQ=\underline{V}\,\underline{I}*

Here P is average or real power in watts, Q is reactive power in volt-amperes reactive (var), and the asterisk denotes complex conjugation. The apparent-power magnitude is

|\underline{S}|=S=VrmsIrms=\sqrt{P2+Q2}

For impedance Z=R+jX,

P=Irms2R, \qquad Q=Irms2X

Positive Q indicates net inductive behavior; negative Q indicates net capacitive behavior. The power factor is

\text{pf}=\frac{P}{S}=\cos\theta

where \theta is the angle by which voltage leads current. A leading power factor corresponds to capacitive current; a lagging power factor corresponds to inductive current.

For the preceding RC circuit,

P=(5.32\ \text{mA})2(1000)\approx28.3\ \text{mW}
Q=(5.32\ \text{mA})2(-1591.5)\approx-45.0\ \text{mvar}

and S=VI=(10.0)(5.32\text{ mA})=53.2 mVA. The negative reactive power confirms capacitive behavior.

6. Signals and Frequency Spectra

A signal is a quantity that conveys information. Signals may be continuous-time or discrete-time, analog or digital, deterministic or random, and periodic or aperiodic.

A time-domain plot shows how amplitude changes with time. Frequency-domain representation shows how a signal’s energy or amplitude is distributed among frequencies. Fourier series represent periodic signals as a DC component plus harmonically related sinusoids. The Fourier transform provides a continuous spectrum for suitable aperiodic signals.

For example, an ideal zero-mean square wave contains its fundamental and odd harmonics. Real circuits attenuate high-frequency harmonics, so finite bandwidth rounds the waveform’s transitions.

Bandwidth is the frequency interval over which a system meets a stated performance criterion. In many first-order systems, the cutoff is defined at a power ratio of one-half, corresponding to an amplitude ratio of 1/\sqrt{2} or −3.01 dB.

Sampling and aliasing

A band-limited signal containing no frequency component at or above B Hz can, in principle, be reconstructed when sampled at

fs > 2B

This is the strict Nyquist condition for avoiding overlap of ideal spectral replicas. Practical systems require transition bandwidth and an anti-aliasing filter, so sampling rates are normally higher than twice the desired signal bandwidth. Frequencies above half the sampling frequency can appear as false lower frequencies after sampling.

7. Decibels

The decibel expresses a logarithmic ratio. For powers P2 and P1,

GdB=10\log10\left(\frac{P2}{P1}\right)

For voltage or current ratios with equal impedances—or where the ratio directly produces a squared power ratio—the corresponding form is

GdB=20\log10\left|\frac{V2}{V1}\right|

The 20-log rule must not be applied indiscriminately when impedances differ. A power ratio of 100 equals 20 dB; a voltage ratio of 10 under equal impedance also equals 20 dB.

Absolute logarithmic levels require a reference. For example, dBm denotes power relative to 1 mW:

PdBm=10\log10\left(\frac{P}{1\ \text{mW}}\right)

Cascaded gains and losses add in decibels, which simplifies system-level calculations.

8. Loading and Grounding

8.1 Loading

A measuring instrument becomes part of the circuit. A source represented by Vth and Rth connected to an instrument resistance Rin produces

Vmeas=Vth\frac{Rin}{Rth+Rin}

Thus, finite input resistance causes loading. If a 1.000 V source has Rth=10.0 kΩ and a meter has Rin=1.00 MΩ, it reads

Vmeas=1.000\frac{1.00\ \text{M}\Omega}{1.010\ \text{M}\Omega}=0.9901\ \text{V}

At high frequency, input capacitance can dominate even when input resistance is large. Oscilloscope probes must therefore be selected and compensated appropriately.

8.2 Ground concepts

The word ground has several meanings that must not be confused:

  • protective earth provides a low-impedance fault-current path for safety;
  • circuit common is a selected reference conductor and may be isolated from earth;
  • chassis ground is the conductive enclosure reference;
  • signal ground is a return path for signal current.

Ground loops occur when multiple return paths enclose an area and carry unwanted current induced by magnetic fields or potential differences. Remedies may include single-point grounding at low frequencies, controlled return planes at high frequencies, differential signaling, shielding, or galvanic isolation. A universal “one-point ground” rule is inappropriate because optimum grounding depends on frequency, geometry, safety requirements, and current paths.

Bench oscilloscopes commonly connect probe-ground clips to protective earth. Attaching such a clip to a live, non-earth-referenced node can create a destructive short circuit and severe shock or arc hazard.

9. Measurement, Uncertainty, and Instruments

9.1 Accuracy, precision, and uncertainty

Accuracy describes closeness to the measurand’s accepted value; precision describes the agreement among repeated observations. Resolution is the smallest displayed or detectable increment. Calibration establishes the relationship between an instrument’s indication and reference standards.

A measurement result should be expressed as an estimate accompanied by uncertainty. Errors may be random or systematic. Repetition can characterize random variation but does not automatically remove systematic bias.

For a calculated quantity y=f(x1,x2,\ldots,xn), first-order propagation of independent standard uncertainties is

uy=\sqrt{\sumk=1n\left(\frac{\partial f}{\partial xk}uxk\right)2}

This approximation assumes small uncertainties, differentiability near the operating point, and negligible covariance. If inputs are correlated, covariance terms must be included. Manufacturer tolerance limits must not be treated automatically as standard deviations; their probability distributions must first be considered.

Worked Example 5: Uncertainty in DC power

Voltage and current are measured as V=5.00 V with standard uncertainty 0.02 V and I=0.500 A with standard uncertainty 0.005 A. For P=VI,

P=(5.00)(0.500)=2.50\ \text{W}

Assuming independent uncertainties,

uP=\sqrt{(IuV)2+(VuI)2}
uP=\sqrt{(0.500×0.02)2+(5.00×0.005)2}
=0.0269\ \text{W}

A suitably rounded result is P=(2.50±0.03) W when the stated uncertainty is interpreted as a standard uncertainty. Expanded uncertainty would require a declared coverage factor, commonly U=kuP.

9.2 Laboratory instruments

InstrumentPrincipal useImportant limitation or practice
Digital multimeterDC/AC voltage, current, resistanceObserve terminal selection, range, fuse, and CAT rating
OscilloscopeWaveform, timing, transient, phaseProbe grounding, bandwidth, sample rate, and input loading matter
Function generatorControlled test waveformOutput amplitude may be specified for a particular load, often 50 Ω
Bench power supplyAdjustable DC excitationSet voltage and current limits before connection
LCR meterResistance, capacitance, inductanceResults depend on test frequency and equivalent-circuit model
Spectrum analyzerAmplitude versus frequencyAvoid input overload and use appropriate attenuation

A voltmeter is connected in parallel; an ammeter is connected in series. Connecting an ammeter directly across a voltage source can cause a short circuit. Resistance should normally be measured only in a de-energized circuit after stored energy has been discharged.

Oscilloscope bandwidth describes analog frequency response, while sample rate describes time discretization. Neither specification alone guarantees faithful capture. Probe bandwidth, rise time, memory depth, triggering, and aliasing also matter.

10. Electrical Safety and Professional Responsibility

Electrical injury depends on current path, magnitude, duration, frequency, contact conditions, and human physiology. Even relatively low voltages can be dangerous under wet conditions, through broken skin, or when connected to high-energy sources.

Essential practices include:

  1. de-energize before modifying a circuit;
  2. verify absence of voltage with a suitable instrument;
  3. discharge capacitors and confirm their voltage;
  4. use current limiting and the lowest practical voltage during development;
  5. remove conductive jewelry and use insulated tools;
  6. keep leads organized and inspect insulation before use;
  7. use correctly rated probes, fuses, and personal protective equipment;
  8. never defeat protective-earth conductors or safety interlocks;
  9. work under authorized procedures for hazardous voltages; and
  10. know emergency isolation and reporting procedures.

Measurement-category ratings—CAT II, CAT III, and CAT IV—describe expected transient environments, not merely steady-state voltage. An instrument marked for a voltage in one category is not automatically safe at the same voltage in a higher-energy category. Applicable institutional rules and standards, such as IEC 61010 for measurement equipment and relevant national wiring regulations, must be followed.

Engineering responsibility also includes truthful reporting of results, documentation of uncertainty, protection of users, and prompt disclosure of unsafe conditions. Fabricating measurements or omitting known limitations can lead to unsafe designs as well as academic or professional misconduct.

Safe laboratory measurement chain Bench supply Voltage set first Current limit enabled Circuit under test Defined common Stored energy checked Voltmeter / DMM Parallel; rated input Oscilloscope Check earth-referenced probe ground before use De-energize before rewiring; verify before touching.
Safe measurement chain from source through current-limited circuit to instruments
Figure: Safe measurement chain from source through current-limited circuit to instruments

Figure: Safe laboratory measurement requires current limiting, correct instrument connection, and verification of grounding.

11. Illustrative Case: Designing a Reliable Sensor Measurement

Background

This fictional case concerns a student team developing a temperature-monitoring unit. A resistive sensor interface has a Thévenin output of 20.0 mV and an output resistance of 5.00 kΩ. The signal contains unwanted 50 Hz interference and is to be digitized for analysis.

Problem

The team initially connects the sensor directly to an acquisition input having 100 kΩ resistance. It assumes that the instrument displays the original sensor voltage and that connecting every chassis and circuit common at multiple points will reduce noise.

Analysis

Loading gives

Vmeas=20.0\ \text{mV}\left(\frac{100}{100+5}\right)=19.05\ \text{mV}

The loading error is approximately −4.76%, which may exceed the sensor’s allowable error. Multiple ground connections may also create a loop that couples 50 Hz current into the small signal. Digitization without an analog anti-aliasing filter can translate out-of-band interference into the measurement band.

Approach and solution

The team inserts a precision buffer amplifier with an input resistance of 10 MΩ. The loaded sensor voltage becomes

Vbuffer=20.0\ \text{mV}\left(\frac{10\ \text{M}\Omega}{10\ \text{M}\Omega+5\ \text{k}\Omega}\right)
\approx19.99\ \text{mV}

A differential input is used so that desired signal is distinguished from common-mode interference. Cable shielding is connected according to the equipment manufacturer’s guidance, and the return-current path is documented rather than guessed. An analog low-pass anti-aliasing filter is placed before the analog-to-digital converter, with its cutoff chosen from the required sensor bandwidth and sampling rate.

The team measures offset, gain error, repeatability, noise, and component tolerances. It records instrument models, ranges, calibration status, environmental conditions, and an uncertainty estimate. Development is performed from a current-limited extra-low-voltage supply.

Outcome

Loading error becomes negligible relative to the required tolerance, interference is reduced, and the digital record is traceable to a documented setup. The improvement comes not from software correction alone but from coordinated impedance design, grounding, filtering, sampling, calibration, and safety.

Learning points

  • Measurement equipment modifies the circuit being observed.
  • Grounding must control actual return paths while preserving protective-earth functions.
  • Anti-aliasing must occur before sampling.
  • Uncertainty and calibration are part of engineering evidence.
  • A technically functional prototype is not complete until it is safe and reproducible.

12. Contemporary Practice and Limitations

Modern instruments integrate automated ranging, digital filtering, spectral estimation, remote control, and data logging. Software and AI-assisted tools can identify anomalies, classify waveforms, or propose component values, but they cannot guarantee valid connections, adequate ratings, correct models, or safe grounding. Automated results must be checked against physical laws, instrument specifications, uncertainty, and independent calculations.

Ideal circuit models also have limits. Components exhibit parasitic effects, saturation, self-heating, noise, aging, and manufacturing variation. Wires possess impedance and propagation delay. Sources have finite output resistance, and loads vary with frequency and operating point. Good engineering therefore combines analytical models with simulation, measurement, uncertainty analysis, and safety review.

Chapter Summary

Voltage is energy per unit charge, current is charge flow rate, and power is the rate of energy transfer. Reference directions and the passive sign convention determine the meaning of calculated signs. Kirchhoff’s laws express charge and energy conservation within lumped circuit models.

Superposition, source transformation, and Thévenin and Norton equivalents simplify linear networks. Sinusoidal steady-state analysis uses RMS phasors and complex impedance. Complex power is \underline{S}=P+jQ=\underline{V}\underline{I}*, distinguishing real, reactive, and apparent power.

Signals can be interpreted in time and frequency domains. Bandwidth, sampling, aliasing, and decibels are essential to electronic measurement and communication. Instruments load circuits, and grounding choices affect safety and signal integrity. Reliable measurements require appropriate instruments, calibration, uncertainty evaluation, documented procedures, and recognition of model limitations. Electrical safety remains an overriding professional obligation.

Key Terms

Aliasing: Appearance of false lower-frequency components when a signal is sampled inadequately.

Apparent power: RMS voltage-current product, measured in volt-amperes.

Bandwidth: Frequency range over which a signal or system satisfies a stated criterion.

Complex power: Quantity \underline{S}=P+jQ combining real and reactive power.

Decibel: Logarithmic unit used to express a power or amplitude ratio.

Ground loop: Unwanted closed return path capable of carrying interference current.

Impedance: Complex ratio of phasor voltage to phasor current.

Kirchhoff’s current law: Statement that the algebraic sum of currents at a lumped node is zero.

Kirchhoff’s voltage law: Statement that the directed voltage sum around a lumped closed path is zero under its circuit-model assumptions.

Loading: Change in circuit behavior caused by connecting another device or instrument.

Norton equivalent: Current source in parallel with an equivalent resistance or impedance.

Passive sign convention: Reference convention in which current enters the positive-voltage terminal.

Phasor: Complex representation of sinusoidal magnitude and phase at a single frequency.

Power factor: Ratio of real power to apparent power.

Protective earth: Safety conductor intended to carry fault current and limit accessible voltage.

Reactive power: Reversible energy-transfer rate associated with inductive or capacitive storage.

RMS value: Effective value defined by the square root of the mean squared waveform.

Superposition: Linear-network method that sums responses caused by independent sources separately.

Thévenin equivalent: Voltage source in series with an equivalent resistance or impedance.

Uncertainty: Quantified dispersion associated with a measurement result.

Review Questions

Short Answer Questions

  1. Define the passive sign convention and explain the meaning of negative power.
  2. State KCL and identify its physical basis.
  3. Why must dependent sources remain active when finding a Thévenin resistance?
  4. Distinguish protective earth from circuit common.
  5. What is the difference between accuracy and precision?

Long Answer Questions

  1. Derive the condition for maximum power transfer from a resistive Thévenin source and discuss its efficiency limitation.
  2. Explain phasor analysis and derive the impedances of ideal resistors, inductors, and capacitors.
  3. Discuss real, reactive, apparent, and complex power, including sign conventions and power factor.
  4. Explain the relationship among time-domain signals, spectra, bandwidth, sampling, and aliasing.
  5. Develop a safe procedure for measuring voltage and current in an unfamiliar laboratory circuit.

Analytical / Application Questions

  1. A 24 V source with 3 Ω series resistance supplies a variable resistive load. Determine the load for maximum power, its power, source power, and efficiency.
  2. A 230 V RMS, 50 Hz source supplies a series circuit containing 40 Ω and 100 mH. Calculate impedance, current, phase angle, real power, reactive power, and apparent power.
  3. A sensor has a 2.00 V open-circuit output and 50 kΩ output resistance. Compare loading errors for 1 MΩ and 10 MΩ instruments and recommend a measurement approach.

Multiple Choice Questions with Answers

Question 1

Under the passive sign convention, an element has v=8\ \text{V} and current i=-2\ \text{A}. What does p=vi indicate?

A. The element absorbs 16 W.

B. The element delivers 16 W.

C. The element stores exactly 16 J.

D. The element has zero power.

Correct Answer: B. The element delivers 16 W.

Question 2

At a lumped circuit node, 5 A and 2 A enter while 4 A leaves. What additional current satisfies KCL?

A. 3 A entering

B. 7 A leaving

C. 3 A leaving

D. 1 A entering

Correct Answer: C. 3 A leaving

Question 3

A 12 V source feeds a divider of 2 kΩ in series with 4 kΩ. The output is taken across the 4 kΩ resistor. What is the open-circuit Thévenin voltage?

A. 4 V

B. 6 V

C. 8 V

D. 12 V

Correct Answer: C. 8 V

Question 4

A series circuit has impedance Z=1000-j1592\ \Omega. Relative to the applied voltage, the current:

A. leads by approximately 58°

B. lags by approximately 58°

C. leads by exactly 90°

D. is in phase

Correct Answer: A. leads by approximately 58°

Question 5

Which expression correctly defines complex power when RMS phasors are used?

A. \underline{S}=\underline{V}\underline{I}

B. \underline{S}=P-jQ for every load

C. \underline{S}=\underline{V}\underline{I}*=P+jQ

D. \underline{S}=V/I

Correct Answer: C. \underline{S}=\underline{V}\underline{I}*=P+jQ

Question 6

What decibel value corresponds to a power ratio of 100?

A. 10 dB

B. 20 dB

C. 40 dB

D. 100 dB

Correct Answer: B. 20 dB

Question 7

A 1.000 V Thévenin source has Rth=10.0\ \text{k}\Omega and is measured by a 1.00 MΩ voltmeter. Approximately what voltage is displayed?

A. 0.500 V

B. 0.909 V

C. 0.990 V

D. 1.010 V

Correct Answer: C. 0.990 V

Question 8

For P=VI, measurements are V=5.00\ \text{V} with uV=0.02\ \text{V} and I=0.500\ \text{A} with uI=0.005\ \text{A}. Assuming independent standard uncertainties, what is uP?

A. 0.0100 W

B. 0.0250 W

C. 0.0269 W

D. 0.0500 W

Correct Answer: C. 0.0269 W

Question 9

Why is an instrument’s measurement-category rating important?

A. It specifies only display resolution.

B. It characterizes the transient-energy environment for which the instrument is designed.

C. It guarantees safe use at any voltage below the displayed range.

D. It eliminates the need for correctly rated probes.

Correct Answer: B. It characterizes the transient-energy environment for which the instrument is designed.

Question 10

A 3 kHz sinusoid is sampled at 4 ksample/s without adequate filtering. At what frequency can it alias in the sampled data?

A. 0.5 kHz

B. 1 kHz

C. 2 kHz

D. 3.5 kHz

Correct Answer: B. 1 kHz

Basic Electronics Engineering
Chapter 1 of 15