Experimental Fluid Mechanics and Uncertainty AnalyticsIntroductionExperimental fluid mechanics converts physical flow behaviour into measurable evidence. Although computational fluid dynamics and analytical models are powerful, experiments remain essential for discovering phenomena, validating models, identifying scale effects, and determining performance under realistic operating conditions. In advanced engineering, the objective is not merely to obtain a numerical reading. It is to establish whether the reading represents the intended physical quantity, quantify its uncertainty, identify bias and random variation, and communicate conclusions that are defensible and reproducible. An experimental result is therefore better represented as Y = y ± U where y is the estimated measurand and U is an expanded uncertainty associated with a stated coverage probability. The result is meaningful only when the measurand, instrumentation, calibration, sampling procedure, environmental conditions, and data-reduction method are specified. Learning ObjectivesAfter studying this chapter, the reader should be able to: - Formulate a fluid-mechanics experiment and define its measurands.
- Select suitable pressure, velocity, flow-rate, force, and optical measurement systems.
- Distinguish accuracy, precision, resolution, sensitivity, repeatability, reproducibility, bias, and uncertainty.
- Propagate uncertainty through nonlinear fluid-mechanics equations.
- Design calibration, sampling, and validation procedures for reliable data.
- Interpret time-resolved measurements and diagnose noise, aliasing, drift, and systematic error.
- Evaluate a practical experimental investigation using traceable and statistically defensible methods.
1. From Physical Question to MeasurandA sound experiment begins with a question that can be answered by a measurable quantity. Examples include: What is the pressure loss across a valve? What is the mean velocity profile in a turbulent boundary layer? At what Reynolds number does separation occur? How does surface roughness alter drag? The measurand is the quantity intended to be measured, including its operational definition. “Velocity at a point” is incomplete unless the point location, coordinate system, averaging interval, temperature condition, and velocity component are specified. A useful experimental specification includes: - physical objective and expected governing physics;
- measurands and units;
- spatial and temporal resolution;
- operating range and environmental conditions;
- required uncertainty and confidence or coverage level;
- calibration and traceability requirements;
- sampling plan and data-rejection rules;
- safety, ethical, and reporting requirements.
Dimensional analysis helps determine the variables that control a phenomenon. For internal flow, important dimensionless groups include the Reynolds number Re = ρVD/μ = VD/ν where ρ is density (kg m⁻³), V is characteristic velocity (m s⁻¹), D is characteristic length (m), μ is dynamic viscosity (Pa s), and ν = μ/ρ is kinematic viscosity (m² s⁻¹). For free-surface flows, the Froude number is Fr = V/√(gL), and for compressible flows the Mach number is Ma = V/a, where g is gravitational acceleration, L is characteristic length, and a is speed of sound. Similarity requires more than matching geometry. A model experiment is dynamically similar when the relevant dimensionless groups are matched or when the unmatched groups are shown to be negligible. If Reynolds-number matching and Froude-number matching cannot both be achieved, the researcher must identify the dominant physics and quantify the resulting scale effect. 2. Measurement Systems in Fluid Mechanics2.1 Pressure measurementStatic pressure is commonly measured with wall taps connected to piezometers, manometers, pressure transducers, or differential-pressure sensors. A differential pressure measurement is Δp = p₁ − p₂ where p₁ and p₂ are pressures at two specified locations. A tap should be flush with the wall and oriented to avoid measuring a significant kinetic-energy component. Tubing introduces response delay, trapped air, condensation, and resonance; these effects are particularly important for unsteady measurements. For a simple liquid-column manometer, neglecting gas-density effects, Δp = (ρm − ρf)gh where ρm is manometer-fluid density, ρf is flowing-fluid density, g is gravitational acceleration, and h is the corrected column-height difference. The equation assumes hydrostatic equilibrium and negligible capillary and meniscus errors. 2.2 Flow-rate measurementVolumetric flow rate is Q = dV/dt = A V̄ where Q is flow rate (m³ s⁻¹), A is cross-sectional area, and V̄ is area-averaged velocity. In a circular pipe, if velocity is uniformly distributed, Q = πD²V/4. For developed laminar flow the velocity is not uniform, so the centreline velocity cannot be substituted for the mean velocity. Common devices include gravimetric or volumetric collection systems, weighing tanks, electromagnetic meters, Coriolis meters, ultrasonic meters, venturi meters, orifice plates, and calibrated nozzles. Differential-pressure meters require a discharge coefficient: Q = Cd A₂ √[2Δp / {ρ(1 − β⁴)}] where Cd is the discharge coefficient, A₂ is throat or orifice area, β = D₂/D₁ is diameter ratio, and ρ is fluid density. This relation assumes steady flow, a specified geometry, appropriate pressure-tap locations, and a calibrated or otherwise justified value of Cd. 2.3 Velocity measurementPitot-static probes infer velocity from stagnation and static pressure. For incompressible flow with negligible elevation difference, V = Cp √(2Δp/ρ) where Cp is a calibration coefficient, often close to unity, and Δp is the measured dynamic pressure. The incompressible form is appropriate when density changes are negligible; compressible flows require a thermodynamic relation involving Mach number and stagnation conditions. Hot-wire anemometry uses convective heat transfer from a heated sensor. Its calibration often follows a King-type relation, E² = A + B Vⁿ where E is bridge voltage, A, B, and n are calibration parameters, and V is velocity. The parameters depend on probe geometry, temperature, fluid properties, and electronics. Hot wires have excellent temporal resolution but are sensitive to contamination, temperature drift, and flow direction. Particle image velocimetry (PIV) estimates displacement of seeded particles between two laser-light-sheet images: V = Δx/Δt where Δx is measured particle displacement and Δt is the inter-frame time. Validity depends on adequate seeding, particle-following ability, optical access, calibration of image scale, suitable interrogation windows, and acceptable out-of-plane motion. Laser safety and eye protection are mandatory. 2.4 Force and torque measurementBalances and load cells measure drag, lift, or moment. A force result must include tare, buoyancy correction where relevant, alignment, structural vibration, and the influence of support interference. A nominal drag coefficient is CD = FD/(½ρV²Aref) where FD is drag force, ρ is density, V is reference velocity, and Aref is reference area. The reference area and sign convention must be reported because different conventions produce different coefficients. 3. Experimental Design and Instrument SelectionInstrument selection should begin with the measurand and required uncertainty, not with an attractive sensor specification. Important criteria include range, overload capacity, sensitivity, resolution, bandwidth, response time, linearity, hysteresis, temperature coefficient, compatibility with the fluid, calibration traceability, and installation disturbance. A sensor with a very small stated resolution may still produce poor data if its calibration bias is large. Conversely, a highly accurate sensor may be unsuitable if its bandwidth is inadequate for the phenomenon of interest. The measurement chain includes the physical sensor, conditioning electronics, acquisition hardware, software, mounting, and data-reduction algorithm. Static and dynamic responseA first-order instrument model is τ dy/dt + y = Kx where x is the input, y is the output, K is static sensitivity, and τ is time constant. For a step input, the normalized response is y(t)/y_∞ = 1 − e^(−t/τ). After approximately 5 time constants, the ideal first-order response is within about 0.7% of its final value. This model is useful for estimating response limitations but should not replace dynamic calibration when resonance or higher-order behaviour is important. The sampling frequency must be sufficiently high for the desired frequency content. Sampling below twice the highest frequency does not guarantee reliable measurement in practice; filtering, sensor dynamics, and anti-aliasing design are also required. Aliasing causes high-frequency content to appear falsely at lower frequencies. An analogue low-pass anti-aliasing filter should precede digitisation, and its cutoff should be selected with the sampling rate and required bandwidth in mind. 4. Calibration, Traceability, and Data QualityCalibration establishes the relationship between instrument indication and a reference value. It may be a one-point zero check, a multipoint static calibration, or a dynamic calibration over the operating bandwidth. A linear calibration model can be written as y = a + bx where x is reference input, y is instrument output, a is offset, and b is sensitivity. Least-squares estimates of a and b should be accompanied by residual analysis rather than accepted solely because the coefficient of determination is high. Calibration should include ascending and descending points to reveal hysteresis, repeated points to estimate repeatability, and environmental conditions representative of the experiment. Traceability means that the measurement result can be related to a recognized reference through an unbroken documented chain of calibrations, each contributing to uncertainty. A calibration certificate does not automatically describe the uncertainty of the final experimental result. The researcher must combine calibration uncertainty with other components such as alignment, geometric measurement, fluid-property uncertainty, spatial positioning, drift, and sampling variability. 5. Uncertainty Analytics5.1 Error, uncertainty, and reportingAn error is the difference between a measured value and an unknown true value. It cannot generally be known exactly. Uncertainty is a quantified doubt about the result. A bias is a systematic effect that shifts results in a consistent direction; it should be corrected where possible, with the uncertainty of the correction retained. Precision describes scatter; accuracy describes closeness to the reference value. Resolution is the smallest indicated increment, not necessarily the smallest reliably detectable physical change. Repeatability concerns the same method, operator, instrument, and conditions over a short interval. Reproducibility allows changed operators, instruments, laboratories, or conditions. For repeated observations x₁, x₂, …, xn, the sample mean is x̄ = (1/n) ∑ᵢ₌₁ⁿ xᵢ and the sample standard deviation is s = √[∑ᵢ₌₁ⁿ(xᵢ − x̄)²/(n − 1)] The standard uncertainty of the mean, assuming independent observations with stable variance, is uA = s/√n. The finite-sample confidence interval may require a Student’s t multiplier rather than the normal multiplier. 5.2 Type A and Type B evaluationType A evaluation uses statistical analysis of repeated observations. Type B evaluation uses other information, including calibration certificates, manufacturer specifications, prior data, resolution, physical models, and expert judgement. The classification concerns the method of evaluation, not whether an effect is random or systematic. For a measurand Y = f(X₁, X₂, …, XN), the first-order combined standard uncertainty is uc²(Y) = ∑ᵢ₌₁ᴺ (∂f/∂Xᵢ)²u²(Xᵢ) + 2∑ᵢ<ⱼ (∂f/∂Xᵢ)(∂f/∂Xⱼ)u(Xᵢ,Xⱼ) Here u(Xᵢ) is the standard uncertainty of input Xᵢ, and u(Xᵢ,Xⱼ) is their covariance. The covariance terms must not be omitted when inputs are correlated, such as when the same calibration factor affects several measurements. If inputs are independent, the covariance terms vanish. For a product of powers, Y = C ∏ᵢ Xᵢaᵢ the relative variance approximation is [uc(Y)/Y]² ≈ ∑ᵢ [aᵢ u(Xᵢ)/Xᵢ]² for independent inputs and small relative uncertainties. This approximation is especially useful for flow coefficients, Reynolds number, and dynamic-pressure relations. An expanded uncertainty is U = k uc(Y) where k is a coverage factor. For approximately normal output distributions, k ≈ 2 is commonly associated with roughly 95% coverage, but the actual coverage depends on distributional assumptions and degrees of freedom. Reporting “±2” without specifying the quantity, units, and coverage interpretation is inadequate. 5.3 Example: uncertainty in velocity from pressure differenceSuppose a Pitot measurement gives Δp = 250 ± 2 Pa and the density is ρ = 1.20 ± 0.01 kg m⁻³. Use V = √(2Δp/ρ), with independent standard uncertainties of 2 Pa and 0.01 kg m⁻³. The velocity estimate is V = √(2×250/1.20) = 20.41 m s⁻¹ For V = (2Δp/ρ)1/2, the relative uncertainty is u(V)/V = ½ √[(u(Δp)/Δp)² + (u(ρ)/ρ)²] Thus, u(V)/V = ½√[(2/250)² + (0.01/1.20)²] = 0.00449 and u(V) = 20.41×0.00449 = 0.0916 m s⁻¹. With k = 2, U ≈ 0.18 m s⁻¹. A suitable report is therefore V = (20.41 ± 0.18) m s⁻¹, with the coverage statement and calibration assumptions included. The units are consistent because Δp/ρ has units m² s⁻². 5.4 Monte Carlo propagationLinear propagation can be unreliable for strongly nonlinear models, large uncertainties, truncated distributions, discontinuities, or near-zero quantities. Monte Carlo propagation samples input distributions, evaluates the measurement model repeatedly, and summarizes the resulting output distribution. It is valuable for PIV vector validation, nonlinear calibration curves, derived turbulence statistics, and uncertainty with bounded or asymmetric inputs. A defensible Monte Carlo analysis must state input distributions, correlations, number of trials, random-seed or reproducibility policy, and the method used to extract coverage intervals. Simulation does not improve an invalid physical model; it only propagates the assumptions embedded in that model. 6. Statistics of Fluid-Mechanics MeasurementsFor a stationary signal x(t), the time mean over duration T is x̄ = (1/T)∫₀ᵀ x(t)dt The fluctuation is x′(t) = x(t) − x̄, and the root-mean-square fluctuation is xrms = √(overline{x′²}). Turbulence intensity for velocity component U is commonly I = urms/Ū, although the precise definition should be stated. A finite record contains sampling uncertainty. Successive turbulent samples are correlated, so the effective number of independent observations is smaller than the number of stored samples. Treating every high-frequency sample as independent can dramatically understate uncertainty. Integral time scales, block averaging, spectral analysis, and convergence plots are useful tools for determining whether a record is long enough. The autocorrelation function indicates dependence between observations; the power spectral density describes how variance is distributed across frequency. Windowing and segment averaging can reduce spectral variance, but they alter frequency resolution. A researcher should specify sampling rate, record length, filtering, window, overlap, detrending, and spectral normalization. Outlier rejection must be physically justified. A vector caused by a laser reflection, a pressure spike caused by valve switching, and a legitimate intermittent separation event are not equivalent. Automated filters should be validated against raw data and should not be used to remove inconvenient physics. 7. Experimental Facilities and Similarity EffectsWind tunnels, water channels, pipe loops, towing tanks, and rotating rigs require facility characterization. Empty-test-section blockage, wall interference, contraction quality, flow uniformity, turbulence intensity, temperature stability, pump pulsation, and vibration can influence results. Facility corrections should be based on an accepted model or calibration database and should carry uncertainty. Boundary conditions must be measured rather than assumed. For a pipe-flow pressure-loss experiment, the researcher should record pipe diameter and roughness, pressure-tap spacing, fluid temperature, flow rate, entrance length, pump condition, and whether the flow is fully developed. The Darcy–Weisbach equation is Δp = f (L/D) (ρV̄²/2) where f is the Darcy friction factor, L is tap spacing, D is diameter, and V̄ is mean velocity. It applies to fully developed internal flow with a clearly defined friction factor convention. Local losses should not be incorrectly included in a friction-factor estimate unless their effects are separated. For wall-bounded flows, probe size and wall proximity can distort the measured profile. Spatial resolution must be related to the smallest relevant scale. In turbulent flows, inadequate resolution causes spatial filtering and generally biases gradients and high-order statistics. 8. Applied Case Study: Pressure-Loss Measurement in a Pipe LoopBackgroundThe following is an illustrative case involving a laboratory water loop used to estimate the Darcy friction factor of a smooth circular pipe. The purpose is to compare measured behaviour with a correlation while demonstrating uncertainty analysis. ProblemA pipe has diameter D = 0.0500 ± 0.0001 m and pressure-tap spacing L = 10.00 ± 0.01 m. At a measured flow rate Q = (0.00200 ± 0.00002) m³ s⁻¹, the differential pressure is Δp = (12.0 ± 0.2) kPa. Water properties at measured temperature are ρ = 998 ± 1 kg m⁻³ and μ = (1.00 ± 0.02)×10⁻³ Pa s. Assume independent standard uncertainties and a negligible elevation difference. AnalysisThe mean velocity is V̄ = Q/A = 4Q/(πD²) Numerically, V̄ = 1.019 m s⁻¹. The Reynolds number is Re = ρV̄D/μ = 50,850 The Darcy friction factor obtained from the measured pressure loss is f = 2ΔpD/(LρV̄²) = 0.0230 The measured flow is turbulent. For a hydraulically smooth pipe, the Blasius estimate, applicable approximately over a restricted turbulent range, is f = 0.3164 Re^(−1/4) = 0.0297. The difference is large enough to require investigation rather than immediate rejection of the experiment. For the measured friction factor, treating f as proportional to Δp D L^(−1) ρ^(−1) V̄^(−2), and noting that V̄ ∝ QD^(−2), the dominant sensitivity is to flow rate and diameter. A first-order relative uncertainty estimate gives approximately [u(f)/f]² ≈ [u(Δp)/Δp]² + [u(L)/L]² + [u(ρ)/ρ]² + [u(Q)/Q]² + [2u(D)/D]² + [4u(D)/D]² where the last two diameter terms arise from the explicit diameter and the velocity dependence. Substitution gives approximately u(f)/f = 0.021, or u(f) ≈ 0.00048. The expanded uncertainty at k = 2 is approximately 0.0010, so the discrepancy with the correlation is not explained by the stated random measurement uncertainty alone. Approach and solutionThe team checks whether the pressure taps include entrance or local losses, verifies the flow-meter calibration gravimetrically, measures temperature at the test section, inspects the pipe for roughness and deposits, and repeats measurements at several flow rates. They also check pump pulsation and pressure-transducer zero drift. A regression of Δp against V̄² is used to distinguish a distributed friction loss from a fixed local loss. If the intercept is nonzero, the tap region may include an unaccounted local loss. OutcomeThe repeated measurements show that the original upstream tap was too close to a developing-flow region. Relocating the tap produces f = 0.0291 ± 0.0010 at k = 2, consistent with the correlation within the combined comparison uncertainty. The outcome illustrates that uncertainty analysis cannot repair a poorly defined measurand or an invalid experimental arrangement; it can, however, reveal where further engineering investigation is needed. Learning points- A pressure difference is meaningful only when tap locations and local effects are controlled.
- Derived quantities can be more sensitive to geometric or flow-rate uncertainty than the raw sensor reading.
- Agreement with a correlation is a validation result, not proof that every aspect of the experiment is correct.
- Repeated measurements, calibration checks, and residual analysis are complementary.
9. Research, Governance, and Emerging PracticeExperimental integrity requires preservation of raw data, metadata, calibration files, analysis scripts, instrument settings, and version history. Results should not be selectively reported because they agree with a preferred model. Any exclusions, filtering, corrections, and failed runs should be documented. Safety includes pressure containment, rotating machinery, electrical isolation, compressed gases, chemicals, lasers, hot surfaces, and biological or environmental hazards. Institutional risk assessment and applicable standards must govern operation. Laser-based velocimetry requires controlled access and appropriate wavelength-specific eye protection. Machine learning can assist with PIV vector validation, surrogate calibration, anomaly detection, and reduced-order modelling. It should not obscure uncertainty or replace physical validation. Training and test data must be separated, sensor drift must be considered, and model predictions should be accompanied by physically meaningful confidence or uncertainty information. A neural network that smooths away intermittent separation is not an improved measurement. Contemporary practice increasingly combines high-speed imaging, embedded sensing, digital twins, Bayesian calibration, and automated uncertainty budgets. Bayesian methods are useful when prior calibration knowledge must be combined with new data, but priors and likelihood assumptions must be stated. Digital twins remain dependent on the quality and representativeness of experimental observations. Best-Practice ChecklistBefore testing, define the measurand, uncertainty target, operating envelope, similarity requirements, and safety controls. During testing, monitor environmental variables, record raw signals, perform zero and span checks, prevent saturation, and document changes. After testing, inspect residuals, assess drift and stationarity, propagate correlated uncertainties, compare independent measurement methods where possible, and report results with units, coverage, calibration status, and limitations. Chapter SummaryExperimental fluid mechanics links physical questions to measurable quantities through careful definition of measurands, similarity parameters, instrumentation, calibration, and facility control. Pressure, flow rate, velocity, force, and optical systems each have characteristic assumptions, response limits, and disturbance mechanisms. Reliable data require attention to spatial and temporal resolution, sampling theory, aliasing, calibration traceability, and physically justified data processing. Uncertainty is not synonymous with sensor resolution or random scatter. Type A and Type B evaluations provide standard uncertainties that must be propagated through the measurement model, including covariance when inputs are correlated. Expanded uncertainty requires an explicit coverage factor and interpretation. Linear propagation is useful for small uncertainties and smooth models, while Monte Carlo methods are appropriate for nonlinear or non-Gaussian cases. Turbulent measurements additionally require treatment of serial correlation, convergence, spectral content, and effective sample size. The pipe-loop case demonstrates that a small numerical uncertainty cannot compensate for an invalid measurand or facility configuration. Experimental conclusions become credible when calibration, physics, statistics, uncertainty, safety, data governance, and transparent reporting are treated as one integrated methodology. Key TermsMeasurand: Quantity intended to be measured, defined with its operational conditions. Calibration: Establishment of the relationship between an instrument indication and a reference value. Traceability: Documented relationship of a result to a recognized reference through an unbroken calibration chain. Accuracy: Closeness of a measured result to a reference or accepted value. Precision: Degree of agreement among repeated measurements. Bias: Systematic effect that shifts results consistently. Resolution: Smallest indicated increment or distinguishable instrument change. Repeatability: Agreement under the same measurement conditions over a short period. Reproducibility: Agreement when specified measurement conditions are changed. Type A evaluation: Uncertainty evaluation based on statistical analysis of observations. Type B evaluation: Uncertainty evaluation based on non-statistical information. Standard uncertainty: Uncertainty expressed as a standard deviation. Combined standard uncertainty: Uncertainty obtained by combining input standard uncertainties. Expanded uncertainty: Combined uncertainty multiplied by a stated coverage factor. Covariance: Measure of joint variation between two input quantities. Aliasing: False low-frequency representation caused by inadequate sampling. PIV: Particle image velocimetry, an optical method for estimating velocity from particle displacement. Dynamic similarity: Condition in which the relevant dimensionless governing parameters are matched. Effective sample size: Number of independent observations represented by correlated data. Measuring system: Complete chain of sensor, conditioning, acquisition, installation, and analysis. Review QuestionsShort Answer Questions- Define a measurand and explain why “velocity at a point” is not a complete measurand specification.
- Distinguish accuracy, precision, resolution, and bias.
- State the assumptions underlying the incompressible Pitot velocity relation.
- What is the difference between Type A and Type B uncertainty evaluation?
- Why can a high-frequency data record contain far fewer independent observations than stored samples?
Long Answer Questions- Explain how an experimental fluid-mechanics investigation should proceed from physical question to uncertainty-qualified result.
- Compare pressure transducers, Pitot probes, hot-wire anemometry, and PIV in terms of principle, strengths, limitations, and appropriate applications.
- Derive the first-order uncertainty expression for a product of independent measured quantities raised to arbitrary powers.
- Discuss calibration traceability, dynamic response, sampling, filtering, and aliasing in an unsteady-flow experiment.
- Explain how facility effects, scale effects, and dimensionless similarity influence the interpretation of model experiments.
Analytical / Application Questions- A velocity is calculated from V = √(2Δp/ρ). Given Δp = 400 ± 4 Pa and ρ = 1.25 ± 0.02 kg m⁻³, calculate V, its standard uncertainty using first-order propagation, and an expanded uncertainty using k = 2.
- Design an uncertainty budget for a pipe-friction experiment. Identify at least six input quantities, explain likely correlations, and propose calibration or verification activities for the dominant components.
- A PIV experiment shows apparently excellent agreement with a CFD velocity field after aggressive vector smoothing. Develop a validation plan that tests seeding, calibration, spatial filtering, rejected vectors, uncertainty, and the possibility that real intermittent flow structures have been removed.
Multiple Choice Questions with AnswersQuestion 1Which quantity is explicitly defined as the quantity intended to be measured? A. Resolution B. Measurand C. Covariance D. Hysteresis Correct Answer: B. Measurand Question 2For an incompressible Pitot measurement with negligible elevation difference, velocity is proportional to which quantity? A. The pressure difference B. The square of the pressure difference C. The square root of pressure difference divided by density D. Density divided by pressure difference Correct Answer: C. The square root of pressure difference divided by density Question 3Which uncertainty evaluation uses repeated observations and statistical analysis? A. Type A B. Type B C. Traceability evaluation D. Sensitivity evaluation Correct Answer: A. Type A Question 4If independent input uncertainties are multiplied by a common calibration factor, which issue must be considered in propagation? A. Mach number only B. Covariance C. Aliasing only D. Wall blockage only Correct Answer: B. Covariance Question 5What is the principal purpose of an anti-aliasing filter? A. To increase sensor range B. To remove all systematic bias C. To limit frequency content before digitisation D. To convert pressure into velocity Correct Answer: C. To limit frequency content before digitisation Question 6For Δp = 250 Pa and ρ = 1.00 kg m⁻³, the incompressible Pitot estimate of velocity is closest to: A. 11.2 m s⁻¹ B. 22.4 m s⁻¹ C. 250 m s⁻¹ D. 500 m s⁻¹ Correct Answer: B. 22.4 m s⁻¹ Question 7Which statement about expanded uncertainty is correct? A. It is always equal to instrument resolution. B. It is obtained by multiplying combined standard uncertainty by a stated coverage factor. C. It excludes calibration uncertainty. D. It is meaningful without specifying coverage. Correct Answer: B. It is obtained by multiplying combined standard uncertainty by a stated coverage factor. Question 8In PIV, velocity is primarily estimated from: A. Temperature divided by pressure B. Particle displacement divided by inter-frame time C. Laser power multiplied by density D. Wall shear stress divided by viscosity Correct Answer: B. Particle displacement divided by inter-frame time Question 9Why is treating every turbulent time-series sample as independent often incorrect? A. Turbulent samples are commonly serially correlated. B. The density is always constant. C. Pressure taps eliminate correlation. D. Sampling automatically removes drift. Correct Answer: A. Turbulent samples are commonly serially correlated. Question 10In the illustrative pipe case, the initial discrepancy with the friction correlation was ultimately associated with: A. An invalid definition of Reynolds number B. A pressure tap located in a developing-flow region C. A zero value of viscosity D. Use of a laser with insufficient wavelength Correct Answer: B. A pressure tap located in a developing-flow region
|